<strong>Project</strong> <strong>Planning</strong> <strong>Manual</strong> | <strong>Rexroth</strong> <strong>MKE</strong> Synchronous Motors Electric Drivesand Controls| <strong>Bosch</strong> <strong>Rexroth</strong> AG 107/131InstallationFig.11-8:4. Mount the terminal box lidConnection <strong>MKE</strong>118 encoder and power cableSet the terminal box lid (9) on the motor. Make sure that no wire can becrushed or damaged.5. Tighten the terminal box lid (9) with the added TFL-coated lid screws (8)with 6.1 Nm.If substitude is necessary, please use for lid screws (8) only IS-Screws according to DIN 4762 with a minimum consistency of 8.8!In case of repeated assembling of the terminal box lid, we recommendto secure the lid screws (8) with Loctite 243.