106/131 <strong>Bosch</strong> <strong>Rexroth</strong> AG | Electric Drivesand Controls<strong>Rexroth</strong> <strong>MKE</strong> Synchronous Motors | <strong>Project</strong> <strong>Planning</strong> <strong>Manual</strong>InstallationWhen using ready-made encoder cables (see Abb. 14-3) remove the fittingwhich is mounted on the motor and use the fitting which is mounted on thecable.It is not necessary to define the cable's outer diameter.(1) Sealing(2) Screwing(3) Use grommets according to the cable diameter(4) Union nut(5) Ready-made power cable(6) Terminal box lid(7) Lid screws(8) Ready-made encoder cableFig.11-7: Mounting of the EExd fitting and <strong>MKE</strong>118 cableLoosen and tighten the cable fittings is not permitted. In this cases,"new grommets" have to be used.The cables, which are thread into the terminal box have be connected accordingto (Abb. 11-8).1. Connect the shieldConnect the ring terminal of the power and encoder cable on the X5 withinthe terminal box lid(Tightening torque 1.3 Nm 10%)2. Connect the power cableLay the wires according to the connection plan ( Fig. 8-4) onto the terminalblock X1 and X2.3. Connect the encoder plugMount the connection lock onto the encoder connector X3.