Design and functionSelect welding task5.10.3.2 Setting the operating point (welding output)NOTEThe operating point setting in JOB "0" (manual) is carried out as described in the chapterof the same name for control M2.4x. The following settings are therefore only intendedfor work in JOBs 1-24.OperatingelementActionn xResultSelect the parameter via which the welding output is to be set:using the panel thicknessusing the wire speedusing the welding current+ +Hold down the "TEST" button and at the same time set the operatingpoint on the step switch.The display shows the required parameters and the open circuitvoltage.If the "Volt" and "Wire feed correction" diodes are flashing, this indicatesan error (e.g. short circuit between torch and workpiece, inductivityerror, etc). To correct the error, press "TEST" again.If the operating mode has already been selected, all the necessary settings will have beenactivated and welding can be started.5.10.3.3 Setting the wire correctionThe wire speed (arc length) can be modified using the wire correction if required.OperatingelementAction ResultSet the wire correction value46099-005224-EW50108.11.2011