Models<strong>TTC40F</strong>Triac controller for Regin NTC sensors.<strong>TTC40F</strong>X Triac controller for external signal 0-10 V DC only .Technical dataGeneralSupply voltage3-phase 210-255/380-415 V AC 50-60 Hz. Automatic adaption.Power outputMaximum 40A/phase. Minimum 4A/phase. Both Y- and Delta- connected loads.Ambient, running Maximum 30°C with no condensation. N.B. <strong>TTC40F</strong> generates 70WAmbient, storage -40 - +50°C.Humidity90% RH maximum.Dimensions (w x h x d) 192 x 222 x 95 mm.Form of protection IP20CEThis product conforms with the requirements of European EMC standards CENELECEN 50081-1 and EN 50082-1, European LVD standards IEC 669-1 and IEC 669-2-1and carries the CE mark.Control unit parameters <strong>TTC40F</strong>Proportional band (Supply air temperature control) 20K, fixed.Reset time(Supply air temperature control) 6 minutes, fixed.Proportional band (Room temperature control) 2K, fixed.IndicatorLED that is lit when power is pulsed to the heater.Sensor inputsTwo (2) inputs for main sensor and maximum/minimum sensor.See Section 6-100 for choice of sensor. N.B. Max/min sensor must be 0...60°C.SetpointSelectable, either internal setpoint potentiometer or external setting device.Signal input0 - 10V DC when running against other controllers.Signal output0-10 V connected to the output unit by wire strap (terminals 7-9).ASetting optionsSetpoint0 - 30°C, adjustable. The choice of sensor determines the controller setpoint range.Minimum limits0 - 30°C, adjustable.Maximum limits20 - 60°C, adjustable.Cycle time6 - 60 seconds, adjustable.Night set-back Possible by using Night Set-back unitNS/D , see datasheet section 1 position 325.<strong>TTC40F</strong>XInputOnly for external input signal 0-10 V DC with adjustable cycling time. No internalcontroll unit. No min- or maximum limiting, all other technical data as above.Switches 1-3SetpointMin.limitIndicatorCycling timeMax.limitSwitches 1 SetpointUp: Internal, Down: External2 Minimum limitUp: Active, Down: Not active3 Maximum limitUp: Active, Down: Not activeWiring and dimensionsPowerL1 INL2 INL3 INL3 OUTL2 OUTL1 OUTSupply voltage:3x210-250/370-415 VACPower outputmax. 3x40AEarthOn <strong>TTC40F</strong> teminals 7 and 9 are connectedby a factory-mounted wire strap.Room temperature control123456HMain sensorMin/max limitsensorConstant supply air123 Main sensor4 HRoom temperature control withexternal setpointExternal setpoint:1 ETG-R430: terminals 2 and23TBI: terminals 1 and 23 H4Main sensor5 MMin/max limit6 gsensor<strong>TTC40F</strong>X external signal 0-10V DC89Signal neutral10 V DC in<strong>TTC40F</strong>X is without terminals 1-7.FOR INDOOR CLIMATE WITH OPTIMUM CONTROLAB ReginBox 116, SE-428 22 Kållered, SwedenVisiting address: Bangårdsvägen 35Phone: +46 31 795 44 60Fax: +46 31 795 38 50www.regin.seE-mail: info@regin.seOrg.nr.: SE5564145502Säte: Mölndal

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!