Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)Description<strong>RAVV</strong> can be combined with 2-way valves RAV-/8, VMT-/8 or VMA 15. Controller closes on risingtemperature.There is a special version with a section of thecapillary tube coiled up to function as minimumtemperature sensor. This version can be used tocontrol air heating coils.<strong>RAVV</strong> is self-acting thermostatic <strong>actuator</strong>primarily for use for temperature control insmall hot water cylinders and to control flowtemperatures in central heating systems.Main data:• DN 10 - 25• k v 0.4 - 1.6 m 3 /h• PN 10 with RAV-/8 and VMT-/8 valvesPN 16 with VMA valves• Setting ranges:10 … 38 °C / 27 … 57 °C / 40 … 70 °C• Temperature:- Circ. water / glycolic water up to 30%:2 … 120 °C with RAV-/8 and VMT-/8 valves2 … 130 °C with VMA valves• Connections:- Internal and external thread• Flow mountingOrderingExample:Temperature controller, DN 15,k v 1.6, PN 16, setting range 27 … 57 °C,t max 130 °C, 2-way valve with ext.thread- 1x <strong>RAVV</strong> thermostatic <strong>actuator</strong>,27 - 57 °CCode No: 013U1252- 1x VMA DN 15 valveCode No: 065F2034Option:- 1x Imm. pocket, brassCode No: 017-4370- 1x Weld-on tailpiecesCode No: 003H6908<strong>RAVV</strong> thermostatic <strong>actuator</strong>PictureSetting range Capillary tube lenght Max. sensor temperatureCode No.(°C) (m) (°C)1)10 … 38 1 - 5013U125510 … 38 5.0 2) 013U125312027 … 57 1 - 5 013U12521) Incl. R p ½ sensor stuffing box2) Effektive lenght including minimum temperature sensorValvesPictureType40 … 70 1 - 5 013U1251DN(mm)k v1)(m 3 /h)RAV 10/8 10 1.1PNinletConnectionoutletCode No.R p 3⁄8 3) R 3⁄8 3) 013U0012RAV 15/8 15 1.2 R p 1⁄2 3) R 1⁄2 3) 013U0017RAV 20/8 20 1.5 R p 3⁄4 3) R 3⁄4 3) 013U0022RAV 25/8 25 1.6 10 R p 1 3) R 1 3) 013U0027VMT 15/8 2) 15 1.2 G 3⁄4 A 4) G 3⁄4 A 4) 065F0115VMT 20/8 2) 20 1.5 G 1 A 4) G 1 A 4) 065F0120VMT 25/8 2) 25 1.6 G 1 1⁄4 A 4) G 1 1⁄4 A 4) 065F0125VMA 15 5) 151) The capacity (k v ) applies to a P-band of 6 °C. Other P-band, see “Technical data”.2) For ordering of Cu fittings, see Accessories.3) According to ISO 7/14) According to ISO 228/15) For ordering ext. thread tailpieces, see Accessories.0.4065F20310.8 16 G 3⁄4 A 4) G 3⁄4 A 4) 065F20330.6 065F20321.1 065F20341.7 065F2035DH-SMT/SI VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 1


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>Ordering (continuous)Accessories for thermostatPicture Type designations Connection Code No.RImmersion pocketp ½ × M14 × 1mm, brass, Ø 11 × 112 mm 017-4370R p ½ × M18 × 1.5mm, stainlees steel, Ø 11 × 112 mm 017-4369Sensor stuffing box R ½ x M14 x 1 mm, rubber EPDM Ø 12.6 x 2.5 x 6 mm 013U0292 1)1) Code includes housing, gasket, 4 washers and sealing boltAccessories for valvesPicture Type designations For valve Dimensions Code No.Compression fittings 1), 2), 3) VMT 15Weld-on tailpiecesExternal thread tailpiecesVMT 20Ø 15 × 1Ø 16 × 1Ø 18 × 1Ø 18 × 1Ø 22 × 1013G4125013G4126013G4128013U0134013U0135VMT 25 Ø 28 × 1 013U0140VMA 15Con. ext. thread acc. toEN 10226-1- 003H6908R ½ “003H6902Valve stuffing box 3) RAV/VMT/VMA 065F00061) Compression fitting consist of compression ring and union2) For copper pipe3) The products can only be ordered in multiple packing containing 10 pieces eachTechnical dataType <strong>RAVV</strong>kV (m 3 /h)for a P-band in °C ofMax.workingpressureMax.diff.pressureMax.testpressureMax.flowtemp.5 1)2 4 6 8 10 12 (bar) (bar) (bar) (°C)RAV 10/8 0.6 0.8 1.1 1.2 1.3 1.4RAV or VMT 15/8 0.6 0.9 1.2 1.3 1.5 1.6RAV or VMT 20/8 0.7 1.2 1.5 1.8 2.1 2.310 0.8 16 120RAV or VMT 25/8 0.7 1.2 1.6 2.0 2.3 2.6VMA 15 (k VS = 0.4) 0.2 0.3 0.4VMA 15 (k VS = 0.63) 0.3 0.5 0.6VMA 15 (k VS = 1.0) 0.4 0.7 0.8162 1)25 130VMA 15 (k VS = 1.6) 0.4 0.8 1.1VMA 15 (k VS = 2.5) 0.7 1.2 1.7 1 1)Materials RAV/VMT VMAValve body Brass DZRValve cone NBR rubber EPDMSpindle - DZRTemperature sensorImmersion pocketCapillary tubeCuBrass or stainless steelCu1) In installations requiring a low-noise function the differential pressure is not to exceed 1 bar.2 VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 DH-SMT/SI


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>Application principlesThe <strong>actuator</strong> <strong>RAVV</strong> must beinstalled in the flow pipelineonly.Hot water cylinderAir heating coilInstallation positionsTemperature controllerThe valve body must be installed in the flowpipeline with the flow in the direction indicatedby the cast-in arrow.The flow temperature must be min. 15 °C higherthan the set closing temperature.Temperature sensorThe sensor must be installed in position fromhorizontal to vercally down.The sensor must always be placed in a pocketwhen the temperature is to be measured directlyin a medium.DH-SMT/SI VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 3


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>Design1. Handle for temperaturesetting2. Setting spring3. Bellows4. Valve stuffing box5. Bottom screw6. Valve body7. Valve cone8. Temperature sensor9. Sensor stuffing box10. Housing of sensor stuffing box11. Gasket of sensor stuffing box12. Sealing bolt of sensorstuffing box1210119SettingsTemperature settingRelation between scale numbers 1 - 5 andclosing temperature.The values given are approximate.DH-SMT/SI VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 5


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>DimensionsØ55R1⁄2100L 5H 278H 1S 1dLS 2d 2L 3L 4L 2Ø9.5<strong>RAVV</strong>-RAV-/8d d 2 Width across flatsDNL L 2 L 3 L 4 L 5 H 1 HISO 7/12 S 1 S 2(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)10 R p 3⁄8 R 3⁄8 59 85 26 52 22 45 93 22 2715 R p ½ R ½ 66 95 29 58 26 45 93 27 3020 R p ¾ R ¾ 74 106 34 66 29 45 93 32 3725 R p 1 R 1 90 125 40 75 34 58 106 41 46<strong>RAVV</strong>-VMT-/8DN1520a b L 1 L 2 H 1Widthacross flatsmm ISO 228/1 (mm) (mm) (mm) S (mm)Ø 15Ø 16Ø 18Ø 18Ø 22G ¾ A 66 90 93 30G 1 A 74 101 93 3725 Ø 28 G 1¼ A 90 120 106 45<strong>RAVV</strong>-VMAa L L1 L2 SDNISO 228/1 (mm) (mm) (mm) (mm)15 G ¾ A 65 131 139 276 VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 DH-SMT/SI


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>Dimensions (continuous)M 14 ×1M 18 ×1.5Immersion pocketWeld-on tailpiecesExternal thread tailpiecesG Ød L Weight(mm) (mm) (mm) (kg)15 15 35 0.18G R L Weight(“) (“) (mm) (kg)¾ ½ 25.5 0.17DH-SMT/SI VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 7


Data sheet<strong>Thermostatic</strong> <strong>actuator</strong> <strong>RAVV</strong>8 VD.52.O6.02 © <strong>Danfoss</strong> 11/2006 DH-SMT/SI