Model SC500 Programmable Single-Channel Transducer Indicator ...

Model SC500 Programmable Single-Channel Transducer Indicator ...

Model SC500 Programmable Single-Channel Transducer Indicator ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Model</strong> <strong>SC500</strong> <strong>Programmable</strong> <strong>Single</strong>-<strong>Channel</strong> <strong>Transducer</strong><strong>Indicator</strong>/ ConditionerOrder Code (See below)• Choice of <strong>Transducer</strong> Inputs• Small 1/8 DIN Form Factor• Automatic Setup, Calibration via Sig Cal• Shunt-Cal, mV/V or Known Load Calibration• Peak/ Valley Capture• Optional Analog Output and RS-232/ RS-485• Field Selectable Frequency Response and CalibrationPhysicalEnvironmentalDisplayPowerAnalog Output (optional)Communications Output(optional)Limits Output (optional)InputForm Factor................1/8 DINCase Material................AluminumTemperature, Operating................40° to 105°F (5° to 40°C)Temperature, Storage................-40° to 195°F (-30° to 90°C)Display Type................Vacuum fluorescentNumeric Display Format................+999,999 to -999,999 (0, 1, 2, 3, 4, 5 decimal places)Digit Size (Normal Mode)................0.2” H x 0.1” W (5mm H x 2.5mm W) (with engineering units)Digit Size (Large Mode)................0.4” H x 0.2” W (10mm H x 5mm W) (no engineering units)Engineering Units Display................4 characters, available in normal mode onlyDisplay Update Per Second................4Power Supply Type................AC (with included wall-mount adapter) or DCDC Power Supply Requirements................10 - 26 VDC @ 1AAC Wall-Mount Adapter (included)................Interchangeable plugs for use in the Americas, Europe,the United Kingdom and Australia (100 - 240 VAC)Voltage Range................5, +/-5, 10 or +/-10 VDC (field selectable)Isolation................500 VDigital-to-Analog Resolution................15 bitsFrequency Response................Same as inputSerial Setup & Output................Isolated RS-232 or RS-485 (factory option)Max. Baud Rate................38400 BaudQuantity................2 Form C or 3 Form A (factory option)Response Time................Same as inputRelay Engergized when Signal is................less than, greater than, inside or outside set pointsContact Ratings................1A @ 30 VDC, 0.5 A @ 50 VACStrain GageMillivoltsHigh LevelVolts/ mAAC/AC LVDTOrder Code AE236 AE237 AE238<strong>Transducer</strong> Typeunamplifiedpressure or loadamplified pressure or load,DC/DC LVDTLVDTRange 0.5 to 21 mV/V +/-5 or +/-10 VDC, 4-20 mA 0.1 to 15 VRMSFrequency Response &ResolutionCalibration Type(Field Selectable)<strong>Transducer</strong> ExcitationSee table on next page See table on next page See table on next pageShunt, mV/V,2-, 3-or 5-point known load5 VDC @ 60 mA max.Shunt,2-, 3-or 5-point known load+12 VDC, +/-15 VDC,+28 VDC2-, 3-or 5-point known load3 VAC @ 5 kHzPush-button 100% Tare Yes Yes YesPush-button Shunt Test Yes Yes No1-888-282-9891www.honeywell.com/sensotec419


<strong>Model</strong> <strong>SC500</strong>Input (continued)FrequencyResponse (Hz)(Field Selectable)Resolution (counts)Step Response (not including min. 10% overrange/ underrange capability)(ms) (typical) Strain Gage High Level AC/AC LVDT2 (fast mode) 40 +/- 50,000 +/- 50,000 +/- 25,0002 440 +/- 50,000 +/- 50,000 +/- 25,0008 110 +/- 25,000 +/- 25,000 +/- 15,00016 55 +/- 20,000 +/- 25,000 +/- 10,00032 28 +/- 10,000 +/- 20,000 +/- 10,00050 16 +/- 5,000 +/- 15,000 +/- 5,000100 8 +/- 5,000 +/- 10,000 +/- 5,000250 3 +/- 2,000 +/- 10,000 +/- 2,000Flexible and Expandable Platform<strong>Channel</strong> Card Options• Strain Gage Input• High Level Volt/ mA• AC LVDTNote:Specify voltage or currentO/P on each cardMounting Options• Bench Mount stand (AA924)• Panel Mount (AA943)• 19” Rack mount for 1 meter (056-0062-00)• 19” Rack mount for 4 meter (023-0066-00)Relay Options• 2 Form C Relay• 3 Form A RelayChassis Options• Math <strong>Channel</strong>• Split Display Virtual <strong>Channel</strong>• AC or Vehicle Power Supply• RS232 or RS485 Output• Additional Analog O/P CardDimensions4.66” (118 mm)3.16” (106 mm)3.78” (96 mm)3.55” (90 mm)1.72”(44 mm)1.89”(48 mm)Typical System DiagramLoad Cell<strong>Model</strong> <strong>SC500</strong>Customer SuppliedChart RecorderAlarm PanelData AcquisitionComputerPLCCable AccessoriesRS232 cable assy with 9 pin D sub connector (6ft.) (AA145)Mating connector for DC power jack (023-0769-01)Relay/ digital output connector/ cable assy (AA144)Replacement wall-mount AC power supply (AA961)Mounting OptionsBench MountPanel Mount (AA944)Portable (see <strong>Model</strong> SC2001)Supplied with InstrumentSoftware AccessoriesSensoCom Instrument Ultility Softwarefor Windows 98/ NT/ 2000(AA183)4201-888-282-9891www.honeywell.com/sensotec


<strong>Model</strong> <strong>SC500</strong><strong>SC500</strong> CapabilitiesFront Panel or Remote TareFlexible User SetupUpdate signature moduleNumber of decimal placesSerial communications (optional)Output voltage (optional)Engineering unitsAlarm outputs (optional)Display averagingmV/V or Shunt Calibration or 5 Point CalibrationRemote SetupmV/V CalibrationShunt Calibration2, 3 or 5 point calibrationfor applied load, pressure,speed, etc.User Selectable Display OptionsDifferent Alarm Configurations (optional)Dual line displayValley trackingPeak trackingUser selectedunitsAlarm on when setpointexceeded and until returnpoint is reachedAlarm on when belowsetpoint and until returnpoint is reachedShows status of alarmsUser selected decimal point6 digit displayLarge Display Mode1-888-282-9891www.honeywell.com/sensotec421


<strong>Model</strong> <strong>SC500</strong><strong>SC500</strong> Capabilities (continued)User Selectable FilteringMath <strong>Channel</strong> (OPtional) Can Act Like PLCUser SelectableFilteringMath ProcessingSig Cal Auto Set UpAnalog & Digital Outputs (Optional)Auto SetupRetrieves Calibration DataSets up the CorrectEngineering UnitsSets the Specific RangeSets up the Correct CalibrationScales Analog OutputPCAnalog MeterData LoggerPLCOptionsOutput OptionsBuilt to Order53a. RS-232 (not available with 53d)53d. RS-485 (not available with 53a)58a. 2 limit set-points with Form C contact relays(not available with 58h)58h. 3 limit set-points with Form A contact relays(not available with 58a)58i. Isolated digital-to-analog (DAC) voltageApproved-Not RoHS CompliantHow to OrderThe order code consists of the product model and the available options.1-888-282-9891Sample Code: AE236 58h<strong>Model</strong> Code Options Codewww.honeywell.com/sensotec422