12.07.2015 Views

LCP Proximal Radius Plates 2.4. Plates for radial ... - Osteosyntese

LCP Proximal Radius Plates 2.4. Plates for radial ... - Osteosyntese

LCP Proximal Radius Plates 2.4. Plates for radial ... - Osteosyntese

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>LCP</strong> <strong>Proximal</strong> <strong>Radius</strong> <strong>Plates</strong> <strong>2.4.</strong><strong>Plates</strong> <strong>for</strong> <strong>radial</strong> head rim and <strong>for</strong> <strong>radial</strong>head neck address individual fracturepatterns of the proximal radius.Compatible withthe <strong>LCP</strong> Distal<strong>Radius</strong> System 2.4and <strong>LCP</strong> CompactHand 2.4Precontoured <strong>for</strong>anatomical fit onthe <strong>radial</strong> head rimand neck<strong>LCP</strong> combi-hole:angular stabilityand/orcompression


<strong>LCP</strong> <strong>Proximal</strong> <strong>Radius</strong> <strong>Plates</strong> <strong>2.4.</strong><strong>Plates</strong> <strong>for</strong> <strong>radial</strong> head rim and <strong>for</strong> <strong>radial</strong>head neck address individual fracturepatterns of the proximal radius.IndicationExtra-articular and intra-articularfractures of the proximal radius andmulti-fragmented <strong>radial</strong> neck fracturesVariety of plates to address individualfracture patternsNine precontoured plates with anatomicalfit address fracture fragments individually– Six <strong>radial</strong> head rim plates to match theanatomy of the <strong>radial</strong> head– Three <strong>radial</strong> head neck plates to capturemore distal fragments– 3 lengths of each plate preclude cuttingthe plates, which can result in tendonirritation– Small plates and screws address fracturefragments individually, with lessoverall implant bulk– Low plate and screw profile, highly polishedsurface and rounded edges minimizepotential <strong>for</strong> tendon and soft tissueirritation/adhesionCompatible with 2.4 systems<strong>LCP</strong> Radial Head <strong>Plates</strong> are compatiblewith the <strong>LCP</strong> Distal <strong>Radius</strong> System 2.4and with <strong>LCP</strong> Compact Hand <strong>2.4.</strong>Ordering in<strong>for</strong>mation<strong>Plates</strong> are available in stainless steel (x=2)and titanium (x=4).<strong>LCP</strong> <strong>Proximal</strong> <strong>Radius</strong> <strong>Plates</strong> 2.4, <strong>for</strong> <strong>radial</strong> head rimx41.680 right, shaft 2 holes, head 5 holes,length 37.5 mmx41.681 left, shaft 2 holes, head 5 holes,length 37.5 mmx41.682 right, shaft 3 holes, head 5 holes,length 46.5 mmx41.683 left, shaft 3 holes, head 5 holes,length 46.5 mmx41.684 right, shaft 4 holes, head 5 holes,length 55.5 mmx41.685 left, shaft 4 holes, head 5 holes,length 55.5 mm<strong>LCP</strong> <strong>Proximal</strong> <strong>Radius</strong> <strong>Plates</strong> 2.4, <strong>for</strong> <strong>radial</strong> head neckx41.690 shaft 2 holes, head 5 holes, length 32 mmx41.691 shaft 3 holes, head 5 holes, length 41 mmx41.692 shaft 4 holes, head 5 holes, length 50 mmPresented by:0123036.000.680 SE_036057 AA 30050113 © 06/2008 Synthes, Inc. or its affiliates All rights reserved <strong>LCP</strong> is a trademark of Synthes, Inc. or its affiliates

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!