Industrial <strong>earth</strong> <strong>leakage</strong> <strong>protection</strong>WRU-10Differential relay with built-in transformerand displayDescriptionFeaturesElectronic differential <strong>protection</strong> relay with builtin28 mm transformer, constituting one unit.}}Type A high-insulation, with high-frequencycurrent filter and high insulation. Monitoringusing true root mean square.}}Display with LEDs and display:- differential <strong>protection</strong> settings.- <strong>protection</strong> trigger current.- <strong>protection</strong> status messages, etc.}}Units with three programmable output contactrelays, one switched and two simple. Themain relay is for the <strong>protection</strong> provided by thecontact or trigger relay of the automatic switchwhile the two others are for the pre-alarm.}}It also has a voltage input for external triggeringand re-arming.}}Assembly on DIN Rail 46277 (EN 50022)}}Reduced three-module size.}}Connection by pluggable terminals.ApplicationWRU-10 relays allow for intelligent differential<strong>protection</strong>. Due to their design features, theyassure maximum safety and continuity in electricalservice, avoiding unwanted tripping..Information on the state of the protected linesis made available through the visualization ofthe instantaneous <strong>leakage</strong> value on the displayscreen together with prealarm signals, allowingfor effective preventive maintenance.ProtectionClassMeasurementSensitivity PROGRAMABLEDelay PROGRAMABLETest y ResetRemote ControlAssociated circuit breakerLED indicatorCircuit breaker controlA superimmunizedTrue root mean square (TRMS)0,03 ... 3 A, scalable up to 30 A by SETUPTime defined: 0,02 ...1 s, scalable up to 10s by SETUP.Inverse curve: Instantaneous or selective (IEC 60947-2)With built-in buttons, T & RExternal Test Option, voltage-free input tripping.Contact or Circuit breaker + trigger coil• Power supply voltage• Trip due to <strong>leakage</strong>• Pre-alarm- Protection parameters- Leakage current/trip reading- Leakage current/trip reading.-TEST statuses and externaltripping.Through an NO/NC switched relay, dependingon the connection with the circuit breakerElectric featuresAuxiliary power supply230 Vac (± 30 %) 50 / 60 HzOutput contacts250 Vac, 5 A / 230 Vac, 250 mAOperating temperature -20 ...+70 ºCConstruction featuresFixing DIN Rail 46722 (EN 50022)Dimensions3 modulesWeight275 gDegree of <strong>protection</strong>IP 20, IP 41 back panelStandardsIEC 60947-2, IEC 60755, IEC 62020, IEC 61008P1-25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!