12.07.2015 Views

SB® 50 Connectors - up to 120 amps

SB® 50 Connectors - up to 120 amps

SB® 50 Connectors - up to 120 amps

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SB ® <strong>50</strong> Silver Plated Wire ContactsUse two silver plated contacts per housing for the best electricalperformance and durability <strong>up</strong> <strong>to</strong> 10,000 mating cycles. See redushingbushings in accessory section for smaller wires.DimensionsMating Loose Piece - A -AWG mm² Force --- Part Numbers --- inches mmMinimum Quantity ................... 1,000 100 .........................6 13.3 Low 1307-BK 1307 0.22 5.596 13.3 High 5900-BK 5900 0.22 5.598 8.4 High 5952-Bk 5952 0.19 4.8312 <strong>to</strong> 10 3.3 <strong>to</strong> 5.3 Low 5953-BK 5953 0.14 3.5612 <strong>to</strong> 10 3.3 <strong>to</strong> 5.3 High 5915-BK 5915 0.14 3.56[ 11.4 ]0.45A[ 7.2 ]0.28[ 30.0 ]1.18[ 7.1 ]0.28SB ® <strong>50</strong> Silver Plated Busbar ContactsUse 2 busbar contacts per housing <strong>to</strong> provide a quick disconnect input or outputbusbar connection. Busbar contacts are for mating with wire contacts only. Part number75BBS includes lock nuts. Locknuts must be ordered separately for B01956P4.MatingType Thread Force ---- Loose Piece Part Numbers ----Minimum Quantity ................. 1,000 20 10 ...Busbar #10-24 High B01915P1 - 75BBSLock Nut #10-24 - H1216P8 110G54 -See Busbar contact drawing onwebsite for further detail.[ 2.0 ]0.08[ 69.1 ]2.72[ 17.1 ]0.68SECTION 3SB ® <strong>50</strong>55A Right Angle Standard Powerclaw PCB ContactsStandard Powerclaw contacts are for use inside a SB ® <strong>50</strong> housingand provide a color coded right angle connection <strong>to</strong> the PCB.Description - Loose Piece Part Numbers -Minimum Quantity .... <strong>50</strong>0 100 .......Tin Plated PC5930T-BK PC5930TSilver Plated PC5930S-BK PC5930S[ 8.0 ]0.32[ 27.4 ]1.08[ 11.4 ]0.45[ 21.6 ]0.85Top View[ 19.05 ]0.7<strong>50</strong>[ 3.7 ]Ø 0.14 (2)[ 22.6 ]0.89[ 35.0 ]1.380[ 23.7 ]0.93[ x ]xSide View[ 63.6 ]2.51See PCB contact drawing on website for further detail.[ 15.6 ]0.6255A Right Angle Mini Powerclaw PCB ContactsRight angle Mini Powerclaw contacts can be used on the PCB edgewithout a SB ® <strong>50</strong> housing on the PCB side. A self polarizing design onlyallow SB ® <strong>50</strong> wire housings <strong>to</strong> mate <strong>to</strong> PCB contacts one way.Description - Loose Piece Part Numbers -Minimum Quantity .... 1,000 100 .......Tin Plated PC5934T-BK PC5934TSilver Plated PC5934S-BK PC5934S[ 7.6 ]0.30[ 8.1 ]0.32[ 2.42 ]0.095[ 6.10 ]0.240[ 24.6 ]0.97[ 17.5 ]0.69[ 12.19 ]0.480[ 25.4 ]1.00[ 1.27 ]0.0<strong>50</strong>- 58 - www.andersonpower.comAll Data Subject To Change Without Notice


55A Vertical Mini Powerclaw PCB ContactsVertical Mini Powerclaw contacts save space by not requiring a SB ® <strong>50</strong>housing on the PCB side. The guide housing is required for <strong>to</strong> provide apolarized connection. (See SB ® <strong>50</strong> accessories).[ 24.3 ]0.96[ 12.2 ]0.48[ 6.25 ]0.246Description - Loose Piece Part Numbers -Minimum Quantity .... 1,<strong>50</strong>0 100 .........Tin Plated PC5933T-BK PC5933TSilver Plated PC5933S-BK PC5933S[ 9.7 ]0.38[2.32]0.091[ 10.29 ]0.405[ 1.27 ]0.0<strong>50</strong>[ 4.98 ]0.196| SB ® <strong>50</strong> CONNECTOR SPECIFICATIONS |ElectricalCurrent Rating Amperes¹ UL 1977 CSAWire <strong>to</strong> Wire UL 1977 (6 AWG) <strong>120</strong> <strong>50</strong>Wire <strong>to</strong> PCB UL 1977 (6 AWG) <strong>50</strong>Voltage Rating AC/DCUL 1977 600PCB Connec<strong>to</strong>r Recommended Voltageper IEC 609<strong>50</strong>-1 Table 2L Pollution Degree2Mini Vert. Contact 522Mini Horiz. Contact <strong>50</strong>4Standard Contact 9<strong>50</strong>Dielectric Withstanding VoltageVolts AC 2,200Avg. Mated Contact Resistance Milliohms¹1 1/4” of #6 AWG wire 0.200PCB Contact <strong>to</strong> Contact 0.<strong>50</strong>0UL Hot Plug Current Rating Amperes - 2<strong>50</strong> cycles at <strong>120</strong>V DCWire- wire<strong>50</strong>APCB- wire40A(Vertical Mini Powerclaw)MaterialsHousingStandard Plastic ResinChem. Resistant ResinContact Retention SpringHousing Flammability RatingUL94 V-0ContactBaseWire PlatingPCB PlatingPolycarbonatePolycarbonate / PBT blendStainless SteelCopper AlloySilverSn or Ag over NiMechanicalWire Size Range AWG mm²Wire Contacts with Bushings 16 <strong>to</strong> 6 1.3 <strong>to</strong> 13.3Max. Wire Insulation Diameter in. mm0.440 11.200Operating Temperature² °F °CStandard -4° <strong>to</strong> 221° -20° <strong>to</strong> 105°Chemical Resistant* -40 <strong>to</strong> 221° -40° <strong>to</strong> 105°*Chemical resistant material not available for PCB guide housingsMating Cycles No Load by Plating Silver (Ag) Tin (Sn)Wire and PCB Contacts 10,000 1,<strong>50</strong>0Avg. Mating / Unmating Force Lbf. NWire <strong>to</strong> Wire Low Force Contacts 10 44Wire <strong>to</strong> Wire High Force Contacts 15 67Standard Powerclaw <strong>to</strong> Wire 15 66Mini Powerclaw <strong>to</strong> Wire 8 36PCB SpecificationsMounting StylePlated Through HoleMax PCB Thickness- in. [mm] Standard: 0.15 [0.381]Mini: 0.25 [0.635]Recommended Traces#8 AWG Cross SectionMin. Contact / Spring Retention Force Lbf. NWire Housing <strong>50</strong> 222Min. Creepage / [Clearance] Distance in. mmStandard Powerclaw 0.374 9.5Mini Vert. Powerclaw 0.213 5.4Mini Horz. Powerclaw 0.205 5.2ProtectionTouch Safety with Wire ContactsIEC 60529IP10SECTION 3SB ® <strong>50</strong>Contact Termination MethodsCrimp³Hand SolderSolder Dip*Wave Solder*Wrench / SocketWire ContactsWire and PCB ContactsPCB ContactsPCB ContactsBusbar Contacts¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP ®recommended <strong>to</strong>oling, and a 25°C ambient temperature. UL rating not <strong>to</strong> exceedthe maximum operating temperature. CSA rating below a 30°C temperature rise.² Limited by the thermal properties of the connec<strong>to</strong>r plastic housing.³ Use APP ® recommended <strong>to</strong>oling only. Alternate <strong>to</strong>ols may adversely affect theperformance of our connec<strong>to</strong>rs along with UL and CSA recognition.All Data Subject To Change Without Noticewww.andersonpower.com - 59 -


| SB ® <strong>50</strong> CONNECTOR TEMPERATURE CHARTS |60SB ® <strong>50</strong>Temperature Rise at Constant Current125SB ® <strong>50</strong>Derating vs. Ambient TemperatureTemperature (°C)<strong>50</strong>40302010Temperature (°C)10075<strong>50</strong>00 10 20 30 40 <strong>50</strong> 60 70 80 90Amperes Applied2<strong>50</strong> 10 20 30 40 <strong>50</strong> 60 70 80 90 100Amperes Applied6 AWG 8 AWG10 AWG 12 AWG6 AWG 8 AWG10 AWG 12 AWG60Mini PowerclawTemperature Rise at Constant Current125Mini PowerclawDerating vs. Ambient TemperatureTemperature (°C)<strong>50</strong>40302010Temperature (°C)10075<strong>50</strong>SECTION 3SB ® <strong>50</strong>00 10 20 30 40 <strong>50</strong> 60 70 80 90Amperes AppliedSB<strong>50</strong>2<strong>50</strong> 10 20 30 40 <strong>50</strong> 60 70 80 90 100110Amperes AppliedSB<strong>50</strong>NOTE: Temperature rise charts are based on a 25°C ambient temperature. Powerclaw charts are based on #8 AWGequivalent copper foil on board side, mated <strong>to</strong> #6 AWG conduc<strong>to</strong>r on wire side.| SB ® Accessories |“T” HandleThe “T” handle makes mating and unmating the connec<strong>to</strong>r easier. Thenon-conductive red plastic material is strong and safe. (2) Self tappingscrews are used <strong>to</strong> secure the handle <strong>to</strong> the connec<strong>to</strong>r housing.Description --------- Part Numbers ---------Minimum Quantity ............................... 1,000 <strong>50</strong> ........Red “T” Handle + Hardware Bag - SB<strong>50</strong>-HDL-REDHardware Bag (2 Screws) - 104G17Red “T” Handle Only 113899P1 -#8 x 5/8” Screw (Order 2 Per Handle) H1<strong>120</strong>P53 -Handle(2) Self-tappingScrewsConnec<strong>to</strong>rHousingDust CoverPrevents dust and dirt from entering the mating interface ofthe connec<strong>to</strong>r when unmated. NOTE: Not a Hermetic Seal.Description ---- Part Numbers ----Minimum Quantity .............................. <strong>50</strong>0 <strong>50</strong> ...Dust Cover with Lanyard Strap, Red 113890P1 134G1Slide cover overmating end.- 60 - www.andersonpower.comAll Data Subject To Change Without Notice


Guide Housings for Vertical Mini Powerclaw ContactsPrevents polarity being reversed when a SB ® <strong>50</strong> is mated<strong>to</strong> vertical mini Powerclaw contacts.Description ------------ Part Numbers -----------Minimum Quantity .... 1,000 <strong>50</strong> ......Black Guide Housing PC-HSG-SB-BK PC-HSG-SBSB<strong>50</strong> Connec<strong>to</strong>rMini-verticalPowerclaw ContactsGuideHousingPCBCable Cl<strong>amps</strong>Durable metal cable cl<strong>amps</strong> securely hold cables <strong>to</strong> prevent accidental strain or pulls from dislodgingwire or contacts from the housing. Cable cl<strong>amps</strong> are recommended for solder terminated wires.Cable SizeAWG or mm² orDescription (Inches O.D.) (mm O.D.) ---- Part Numbers ----Minimum Quantity ........................................................................................... <strong>50</strong>0 <strong>50</strong> ...Self Attaching for Discrete Conduc<strong>to</strong>r 8 <strong>to</strong> 6 10 990-BK 990Self Attaching for Discrete Conduc<strong>to</strong>r 12 <strong>to</strong> 10 4 <strong>to</strong> 6 990G2-BK 990G2Bolt on for Discrete Conduc<strong>to</strong>r 12 <strong>to</strong> 6 4 <strong>to</strong> 10 990G1-BK 990G1Bolt on for Bundled Conduc<strong>to</strong>r (0.320 <strong>to</strong> 0.4<strong>50</strong>) (4.27 <strong>to</strong> 11.43) 5905-BK 5905SECTION 3SB ® <strong>50</strong>990 990G1 5905Self attaching discrete conduc<strong>to</strong>r. Bolt on discrete conduc<strong>to</strong>r. Bolt on bundled conduc<strong>to</strong>rs.The given wire O.D. information is an estimate. Cable cl<strong>amps</strong> shouldbe evaluated for performance with the actual wire <strong>to</strong> be used.Reducing BushingsUse with contact part number 5900-BK or 1307-BK <strong>to</strong> allow a smaller wire <strong>to</strong> be used with the connec<strong>to</strong>r.Electrical capability is derated with smaller wire.Dimensions- ID - - Length -Contact Barrel Size Wire Size -------- Part Numbers -------- inches mm inches mmMinimum Quantity ...................................................... 3,000 1,000 100 ...................................................#6 AWG [13.3 mm²] #8 AWG [8.4 mm²] - 5912-BK 5912 0.18 4.57 0.45 11.43#6 AWG [13.3 mm²] #12- 10 AWG [3.3- 5.3 mm²] 5910-BK - 5910 0.14 3.56 0.47 11.94#6 AWG [13.3 mm²] #16- 14 AWG [1.3- 2.1 mm²] 5913-BK - 5913 0.09 2.29 0.47 11.94LengthIDWire EntranceAll Data Subject To Change Without Notice15351 DS-SB<strong>50</strong> REV C3.1www.andersonpower.com - 61 -


SB ®- Tooling InformationLoose PieceReeled PartWire Size Part NumbersLoose Piece Contact Crimp Tools Numbers Reeled Contact Crimp ToolsAWGmm²#6 13.3SilverPlating13075900#8 8.4 5952#10 / 12 5.3 / 3.359531388G75915#1 42.4 1323G1#2 33.6 1319#4 21.2 1319G4#6 13.3 1319G61/0 53.5 1382HandTool1309G41368orPneumaticBench Tool + Die + Loca<strong>to</strong>r1387G11387G11387G21388G61388G31388G41303G13SB<strong>50</strong>SB<strong>120</strong>SB1751389G61389G41304G32NumberofCrimpsSingleSingleDoubleTin Plating265G51385523-1265G6 1385522-1N/AATSApplica<strong>to</strong>r ATS Press Air Feed Kit2-565435-2 692655-11725900-2or[3-54<strong>50</strong>0-1]N/A1424266-1or[354578-1]#1 42.4 13471387G11388G31389G3Single#2 33.6 1383 13681387G2 1303G13 1304G32 Double#4 21.1 13841387G1 1388G3 1389G3 Single1387G2 1303G13 1304G32 Double#6 13.3 1348 1387G1 1388G4 1389G3 SingleSB3<strong>50</strong>300mcm 152 910 N/ASingleN/AN/ASECTION 3SB ®4/0 107.2 908 1303G33/0 85 9162/0 67.4 90713681387G21303G121304G31DoubleN/AN/A1/0 53.5 917NOTE: See website for the most current informatmion.All Data Subject To Change Without Noticewww.andersonpower.com - 75 -