Axial Piston Pump Series PV
Axial Piston Pump Series PV Axial Piston Pump Series PV
Catalogue HY11-3243/UK Hydraulic cicuit, ordering examples PI PVplus UK.PM6.5 RH 38 Axial piston pump Series PV Ordering Examples Example 1 Example 2 PV pump with fast response remote pressure control, Same pump, accessories not fitted: relief valve with 2 pressure stages, electrical pressure PV * * * * * * * * FR1; 1 = PVAC2PCMNSJP selection, nitrile seals, spindle adjustment, 24 VDC solenoid, plug to DIN 46350 accessories fitted: PV * * * * * * * * FRZ; Z = PVAC2PCMNSJP Example 3 Usable for horsepower control and proportional volume control, too. Schematic PVAC1P* Schematic PVAC1E* Schematic PVAC2P* Schematic PVAC2E Parker Hannifin GmbH Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-3243/UK Ordering code, dimensions PV For PV Pump Series PI PVplus UK.PM6.5 RH AC Accessories for Compensators Code Function 1P Max. pressure relief 1E 1 pressure, electrical unloading 2P 2 pressures, electrical selection 2 pressures + stands 2E electrical selection low pressure default 2 pressures + stands 2M electrical selection stand by default PP Prop. relief valve with seal option E M Code Seals N NBR V FPM E EPR 39 Axial piston pump Series PV Function Mounting Metric Seals Adjustment Solenoid Solenoid Nominal Design Bolts 1) Accessories pressure Series 350bar not required for order 2) Code Mounting bolts C For single compensators type R or F T For 2-valve-compensator type T S without bolts For spare parts and replacement kits see manual PVI-PVAC-UK; available upon request. Please order plugs separately. See catalogue HY11-2500/UK, chapter 2, accessories. Dimensions PVAC1P* Adjustment Code S Adjustment Code L Pressure relief valve mounted on 2-valve pressure-flow compensator type T PVAC2P* PVAC2E*/2M* High pressure DC solenoid 205 AC solenoid 190 Low pressure 2-pressure relief valve, electrical selection, mounted on compensator type R or F PVAC1E* High pressure Code Adjustment Spindle S with lock nut L DIN lock 1) not with function PP DC solenoid 205 AC solenoid 190 DC solenoid 241 AC solenoid 211 35 Code Solenoid accessories omit For function 1P & PP C W Conduit box with free wires DIN plug socket without plug Code Solenoid voltage omit For function 1P & PP Y 110V/50Hz - 120V/60Hz T 220V/50Hz - 240V/60Hz J 24V DC 2) other pressures on request Pressure relief valve, electrical unloading, mounted on compensator type R or F Low pressure 2-pressure relief valve, electrical selection and unloading, mounted on compensator type R or F Parker Hannifin GmbH Hydraulic Controls Division Kaarst, Germany
- Page 1 and 2: Axial Piston Pump Series PV Variabl
- Page 3 and 4: Catalogue HY11-3243/UK Table of con
- Page 5 and 6: Catalogue HY11-3243/UK Characterist
- Page 7 and 8: Catalogue HY11-3243/UK Ordering Cod
- Page 9 and 10: Catalogue HY11-3243/UK Noise reduct
- Page 11 and 12: Catalogue HY11-3243/UK Efficiency a
- Page 13 and 14: Catalogue HY11-3243/UK Efficiency a
- Page 15 and 16: Catalogue HY11-3243/UK Dimensions P
- Page 17 and 18: Catalogue HY11-3243/UK Dimensions P
- Page 19 and 20: Catalogue HY11-3243/UK Dimensions P
- Page 21 and 22: Catalogue HY11-3243/UK Dimensions P
- Page 23 and 24: Catalogue HY11-3243/UK Dimensions P
- Page 25 and 26: Catalogue HY11-3243/UK Kits Seal ki
- Page 27 and 28: Catalogue HY11-3243/UK Pump Combina
- Page 29 and 30: Catalogue HY11-3243/UK Compensators
- Page 31 and 32: Catalogue HY11-3243/UK Load-sensing
- Page 33 and 34: Catalogue HY11-3243/UK Horse power
- Page 35 and 36: Catalogue HY11-3243/UK Electrohydra
- Page 37: Catalogue HY11-3243/UK Electrohydra
- Page 41 and 42: Catalogue HY11-3243/UK General inst
- Page 43 and 44: Catalogue HY11-3243/UK Notes PI PVp
Catalogue HY11-3243/UK<br />
Ordering code, dimensions<br />
<strong>PV</strong><br />
For<br />
<strong>PV</strong> <strong>Pump</strong><br />
<strong>Series</strong><br />
PI <strong>PV</strong>plus UK.PM6.5 RH<br />
AC<br />
Accessories<br />
for<br />
Compensators<br />
Code Function<br />
1P Max. pressure relief<br />
1E<br />
1 pressure,<br />
electrical unloading<br />
2P<br />
2 pressures,<br />
electrical selection<br />
2 pressures + stands<br />
2E electrical selection<br />
low pressure default<br />
2 pressures + stands<br />
2M electrical selection<br />
stand by default<br />
PP<br />
Prop. relief valve with<br />
seal option E<br />
M<br />
Code Seals<br />
N NBR<br />
V FPM<br />
E EPR<br />
39<br />
<strong>Axial</strong> piston pump<br />
<strong>Series</strong> <strong>PV</strong><br />
Function Mounting Metric Seals Adjustment Solenoid Solenoid Nominal Design<br />
Bolts<br />
1)<br />
Accessories pressure <strong>Series</strong><br />
350bar not required<br />
for order<br />
2)<br />
Code Mounting bolts<br />
C For single compensators type R or F<br />
T For 2-valve-compensator type T<br />
S without bolts<br />
For spare parts and replacement kits see manual <strong>PV</strong>I-<strong>PV</strong>AC-UK; available upon request.<br />
Please order plugs separately. See catalogue HY11-2500/UK, chapter 2, accessories.<br />
Dimensions<br />
<strong>PV</strong>AC1P*<br />
Adjustment<br />
Code S<br />
Adjustment<br />
Code L<br />
Pressure relief valve mounted on 2-valve pressure-flow compensator<br />
type T<br />
<strong>PV</strong>AC2P* <strong>PV</strong>AC2E*/2M*<br />
High<br />
pressure<br />
DC solenoid 205<br />
AC solenoid 190<br />
Low<br />
pressure<br />
2-pressure relief valve, electrical selection, mounted on compensator<br />
type R or F<br />
<strong>PV</strong>AC1E*<br />
High<br />
pressure<br />
Code Adjustment<br />
Spindle<br />
S<br />
with lock nut<br />
L DIN lock<br />
1) not with function PP<br />
DC solenoid 205<br />
AC solenoid 190<br />
DC solenoid 241<br />
AC solenoid 211<br />
35<br />
Code Solenoid accessories<br />
omit For function 1P & PP<br />
C<br />
W<br />
Conduit box<br />
with free wires<br />
DIN plug socket<br />
without plug<br />
Code Solenoid voltage<br />
omit For function 1P & PP<br />
Y 110V/50Hz - 120V/60Hz<br />
T 220V/50Hz - 240V/60Hz<br />
J 24V DC<br />
2) other pressures on request<br />
Pressure relief valve, electrical unloading, mounted on compensator<br />
type R or F<br />
Low<br />
pressure<br />
2-pressure relief valve, electrical selection and unloading, mounted on<br />
compensator type R or F<br />
Parker Hannifin GmbH<br />
Hydraulic Controls Division<br />
Kaarst, Germany