01.12.2012 Views

Axial Piston Pump Series PV

Axial Piston Pump Series PV

Axial Piston Pump Series PV

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Catalogue HY11-3243/UK<br />

Compensators dimensions<br />

Remote pressure compensator, code FRC<br />

Load sensing compensator, code FFC<br />

All control ports G1/4 optional M 12 x 1.5; ISO 6149-1<br />

(threads options 7 and 8) or 7/16-20 UNF (threads option 3)<br />

74.5<br />

pressure pilot port P P (code FRC)<br />

load-sensing-port<br />

P F (code FFC)<br />

2-valve compensator, code FT1<br />

80<br />

Seal kit, compensator<br />

PI <strong>PV</strong>plus UK.PM6.5 RH<br />

T<br />

P<br />

interface NG6, CETOP 03<br />

load sensing port P F<br />

42.5<br />

24<br />

29<br />

<strong>Axial</strong> piston pump<br />

<strong>Series</strong> <strong>PV</strong><br />

Remote pressure comp. with interface NG6, code FR1<br />

Load sensing comp. with interface NG6, code FF1<br />

Proportional p-Q-compensator, code FPR (for code<br />

F<strong>PV</strong> lower valve only without interface)<br />

LVDT for proportional compensator Pilot valve for horse power compensator<br />

round connector<br />

M 12 x 1<br />

5 pins<br />

pump body<br />

SK <strong>PV</strong>C<br />

Seal kit<br />

Compensator<br />

for axial<br />

piston pump<br />

series <strong>PV</strong><br />

69<br />

Seal<br />

40<br />

Code Seal<br />

N NBR<br />

V FPM<br />

E EPR<br />

50<br />

40<br />

2 x M5 - 10 deep optional 10-32 UNC<br />

(threads option 3 and 7)<br />

31<br />

31.5<br />

T<br />

P<br />

32,5<br />

load-sensing-port P F (code FF1)<br />

(plugged for code FR1 )<br />

interface NG6, CETOP 03<br />

40<br />

pump body<br />

Interface NG6, CETOP 03<br />

2 x M5 - 10deep in<br />

pump body (see note above)<br />

Seal kit includes all seals for all single compensator options and the<br />

seals for LVDT and horse power pilot valve. For 2-valve-compensators<br />

two seal kits are to be ordered.<br />

Spare parts lists and ordering codes for replacement compensator<br />

valves see manual <strong>PV</strong>I-<strong>PV</strong>C-GB; available upon request<br />

34<br />

49<br />

Parker Hannifin GmbH<br />

Hydraulic Controls Division<br />

Kaarst, Germany

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!