12.07.2015 Views

Simulator Configuration Guide for Synopsys Models

Simulator Configuration Guide for Synopsys Models

Simulator Configuration Guide for Synopsys Models

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 1: Using <strong>Synopsys</strong> <strong>Models</strong> with <strong>Simulator</strong>s<strong>Simulator</strong> <strong>Configuration</strong> <strong>Guide</strong>TracePath ON | OFFEnables or disables tracing of paths to files used to determine versions of models.The default is OFF.Verbose ON | OFFEnables or disables the generation of error messages when a SmartModel instancecannot be created. The default is OFF.NoLicenseFatal ON | OFFWhen set to ON, causes the SWIFT session to send a fatal error message to thesimulator and terminate if any SmartModel in the simulation fails to authorize. Thedefault is OFF.AttentionYou must invoke the TraceTimeFile, TracePath, and NoLicenseFatalcommands be<strong>for</strong>e the start of the simulation run if you want them to takeeffect <strong>for</strong> that session.Fault SimulationsThe SmartModel Library fault simulation capability is folded into the logic simulationSmartModel Library so that only one set of directories and utilities need to be installedand maintained. Fault simulation availability depends on the:●●Model—Note that the following types of models are incompatible with faultsimulation:❍❍Hardware verification (HV) models are driven by PCL commands rather thanmachine instructions and do not respond adequately to propagated faults. Faultsimulation results may not be as accurate when HV models are present in thecircuit.Flex<strong>Models</strong> do not support fault simulation.<strong>Simulator</strong>—Fault analysis is supported by Mentor’s QuickFault II, VEDA’sVerdictFault, and Teradyne’s LASAR. For more in<strong>for</strong>mation about fault simulationsupport, refer to your simulator documentation.In most cases, you can use the same circuit description <strong>for</strong> both logic and faultsimulation. However, you may need to supply different circuit stimuli <strong>for</strong> each type ofsimulation. All model messages except version, copyright, and configuration errormessages are suppressed in fault simulation. Usage and timing messages are suspendedbecause they are meaningless in a fault simulation. In order to work efficiently during afault simulation, each model manages its own diverge and converge operations.22 <strong>Synopsys</strong>, Inc. October 6, 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!