12.07.2015 Views

Simulator Configuration Guide for Synopsys Models

Simulator Configuration Guide for Synopsys Models

Simulator Configuration Guide for Synopsys Models

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Simulator</strong> <strong>Configuration</strong> <strong>Guide</strong>Chapter 7: Using QuickSim II with <strong>Synopsys</strong> <strong>Models</strong>This Signal Instance command per<strong>for</strong>ms a similar function to that of the lm MeasureTiming utility. Timing measurement is particularly useful <strong>for</strong> ASIC verification. Formore in<strong>for</strong>mation about ASIC verification and timing measurement (.TIM) file <strong>for</strong>mat,refer to the LM-family Modeler Manual or the ModelSource User’s Manual.NoteThe timing measurement (.TIM) file can be converted to a Shell Softwaredelays (.DLY) file by using the lm Create Timing File utility. (For morein<strong>for</strong>mation, refer to the LM-family Modeler Manual or the ModelSourceUser’s Manual.) The delays file can then be converted into a technology file,if desired, by using the lm_model utility with the -Step Timing option.Loop ModeThe SIGnal INSTance loop command turns on the modeling system pattern loopingcapability (loop mode) <strong>for</strong> the currently selected instance. In loop mode, the modelingsystem continually replays the complete pattern history of the selected instance to thedevice. The SIGnal INSTance noloop command turns off pattern looping.Pattern looping is a model development feature useful <strong>for</strong> analyzing the device behaviorand pattern history with an oscilloscope or logic analyzer connected to the device.However, while loop mode is enabled, no other user can access the modeling system;patterns are replayed to the selected device exclusively until loop mode is disabled. Forthis reason, QuickSim II returns an error if this command is specified when more thanone user is accessing the modeling system.Printing Model In<strong>for</strong>mationA number of Signal Instance commands are available <strong>for</strong> printing in<strong>for</strong>mation about theselected model instances. The SIGnal INSTance dump command prints all in<strong>for</strong>mationavailable about the currently selected instances, including:●●●Instance IDName of the modeling system in which the hardware model is locatedSetting <strong>for</strong> test vector logging (On or Off)● Setting <strong>for</strong> indeterminate strength mapping (S or Z)●●●Setting <strong>for</strong> Shell Software timing (On or Off)Model name, as specified in the Shell Software device_nameSetting <strong>for</strong> timing measurement (On or Off)October 6, 2003 <strong>Synopsys</strong>, Inc. 183

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!