Chapter 7: Using QuickSim II with <strong>Synopsys</strong> <strong>Models</strong><strong>Simulator</strong> <strong>Configuration</strong> <strong>Guide</strong>QuickSim II Command Line SwitchesWhen QuickSim II is invoked from the command line, the following switches are theonly ones recognized by Smart<strong>Models</strong>.Timing Mode SwitchUse the -timing_mode switch to set the global timing mode to minimum, maximum, ortypical. Unit delay timing mode is not currently supported. Use the following syntaxwhen setting this switch:-timing_mode { min | max | typ }Time Scale SwitchUse the -time_scale switch to adjust time values (delays and checks) to the desiredresolution by specifying the time scale in nanoseconds (ns). The default is 0.1 ns. Usethe following syntax when setting this switch:-time_scale timescaleConstraint Mode SwitchUse the -constraint_mode switch to enable or disable timing constraint checking. Thedefault is “off”. Any value other than “off” causes a model to per<strong>for</strong>m constraintchecking. Use the following syntax when setting this switch:-constraint_mode { off | state_only | messages }136 <strong>Synopsys</strong>, Inc. October 6, 2003