<strong>Simulator</strong> <strong>Configuration</strong> <strong>Guide</strong>Chapter 7: Using QuickSim II with <strong>Synopsys</strong> <strong>Models</strong>The LMC_USE_32BIT environmental variable is a “set/no-set” variable. That is, youcan set it to any value (even zero) to turn on 32-bit support on a 64-bit plat<strong>for</strong>m. If youdo not set it at all, the default condition is 32-bit models on 32-bit plat<strong>for</strong>ms, or 64-bitmodels on 64-bit plat<strong>for</strong>ms. You only set this environmental variable (to any value)when you are on a 64-bit plat<strong>for</strong>m using 32-bit models and simulators.Using Smart<strong>Models</strong> and Flex<strong>Models</strong> withQuickSim IINoteQuickSim II cannot simulate 64-bit FlexModel or 64-bit Smart<strong>Models</strong>.This section explains how to use Smart<strong>Models</strong> and Flex<strong>Models</strong> with QuickSim II. Touse Flex<strong>Models</strong> with QuickSim II, you use C-only Command Mode. For in<strong>for</strong>mation onC-only Command Mode, refer to “Using Flex<strong>Models</strong> with SWIFT <strong>Simulator</strong>s” onpage 23. The rest of this section explains required installation steps and how to usemodel symbols in the schematic capture front-end to the simulator. This in<strong>for</strong>mation isorganized in the following major subsections:● “Installing the QuickSim II SWIFT Interface” on page 125● “Using Smart<strong>Models</strong>/Flex<strong>Models</strong> with QuickSim II” on page 127● “Schematic Capture” on page 127● “Logic Simulation” on page 134● “Custom Symbols” on page 144Installing the QuickSim II SWIFT Interface<strong>Synopsys</strong> ships the part of QuickSim II that communicates with the SWIFT interface <strong>for</strong>versions of QuickSim II prior to the D.1 release. If you are using a version of QuickSimII prior to D.1, you must install the Mentor Graphics application software <strong>for</strong> eachMentor Graphics user tree.AttentionBeginning with version D.1 of QuickSim II, Mentor Graphics assumedresponsibility <strong>for</strong> their integration of the SWIFT interface. If you are usingversion D.1 or higher, refer to the Mentor Graphics documentation <strong>for</strong>in<strong>for</strong>mation about using SWIFT.October 6, 2003 <strong>Synopsys</strong>, Inc. 125

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!