Table 36-37. Current consumption for modules and peripherals.Symbol Parameter Condition (1) Min. Typ. Max. UnitsI CCTemperature sensor 95 µAULP oscillator 1.0 µA32.768kHz int. oscillator 27 µA2MHz int. oscillator85µADFLL enabled with 32.768kHz int. osc. as reference 11532MHz int. oscillator270µADFLL enabled with 32.768kHz int. osc. as reference 460PLL20x multiplication factor,32MHz int. osc. DIV4 as reference220 µAWatchdog Timer 1 µABODContinuous mode 138µASampled mode, includes ULP oscillator 1.2Internal 1.0V reference 100 µA3.0ADC250kspsV REF = Ext refCURRLIMIT = LOW 2.6CURRLIMIT = MEDIUM 2.1mACURRLIMIT = HIGH 1.6DAC250kspsV REF = Ext refNo loadNormal mode 1.9Low Power mode 1.1mAACHigh Speed Mode 330Low Power Mode 130µADMA 615KBps between I/O registers and SRAM 115 µATimer/Counter 16 µAUSART Rx and Tx enabled, 9600 BAUD 2.5 µAFlash memory and EEPROM programming 4 mANote: 1. All parameters measured as the difference in current consumption between module enabled and disabled. All data at V CC = 3.0V, Clk SYS = 1MHz external clockwithout prescaling, T = 25C unless other conditions are given.XMEGA A3U [DATASHEET]8386C–AVR–02/201392