12.07.2015 Views

Liquid autoHDL Cholesterol Reagent Set - BioPacific Diagnostic Inc.

Liquid autoHDL Cholesterol Reagent Set - BioPacific Diagnostic Inc.

Liquid autoHDL Cholesterol Reagent Set - BioPacific Diagnostic Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Liquid</strong><strong>autoHDL</strong> TM <strong>Cholesterol</strong><strong>Reagent</strong> <strong>Set</strong>Materials Required but not Provided1. An <strong>autoHDL</strong>/LDL <strong>Cholesterol</strong> Calibrator.2. HDL cholesterol controls3. Automated clinical chemistry analyzer capable of accommodating tworeagentassays.ProcedureBelow is a general example of the <strong>autoHDL</strong> TM test procedure for anautomated analyzer. All analyzer applications should be validated inaccordance with NCEP and CLIA recommendations. 10 For assistance withapplications on automated analyzers, please contact the Technical ServiceDepartment.37°C 37°CSample + <strong>Reagent</strong> 1 ----‣ <strong>Reagent</strong> 2 ----‣ Measurement (Absorb. Difference4ul 300ul 5min. 100ul 5min. between 700nm & 600nm)IIIVHDL-C ResultLimitations1. Anticoagulants containing citrate should not be used.2. Protect the reagents from direct sunlight.3. Store the reagents as per instructions.4. Samples with values greater than 150 mg/dl must be diluted 1:1 withsaline and re-assayed. Multiply the result by two.CalibrationThe <strong>autoHDL</strong>/LDL TM <strong>Cholesterol</strong> Calibrator is required for calibration. Thevalue of the <strong>autoHDL</strong>/LDL TM calibrator was assigned by procedurestraceable to the National Reference System for <strong>Cholesterol</strong> (NRS/CHOL).Refer to <strong>autoHDL</strong>/LDL TM <strong>Cholesterol</strong> Calibrator kit package insert forinstructions. If control results are found to be out of range, the procedureshould be recalibrated.Quality ControlReliability of test results should be routinely monitored with control materialsthat reasonably emulate performance of patient specimens. 10 Quality controlmaterials are intended for use only as monitors of accuracy and precision.The National <strong>Cholesterol</strong> Education Program (NCEP) Lipid StandardizationPanel (LSP) recommends two levels of controls, one in the normal range(35-65 mg/dl) and one near the concentrations for decision making(

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!