12.07.2015 Views

Saunier-Duval-Thema-Classic-F24e-Installation-manual

Saunier-Duval-Thema-Classic-F24e-Installation-manual

Saunier-Duval-Thema-Classic-F24e-Installation-manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Important InformationGas safety (<strong>Installation</strong> and use) RegulationsIn your interests and that of gas safety, it is the law that ALL gasappliances are installed and serviced by a competent personin accordance with the regulations.Gas leak or faultWARNING: If a gas leak or fault exists or is suspected, turn theboiler off and consult the local gas supply company or yourinstallation/service company.Testing and CertificationThis boiler is tested and certificated for safety andperformance. It is therefore important that no alteration ismade to the boiler, without permission, in writing, fromHepworth Heating Ltd.Any alteration not approved by Hepworth Heating Ltd.,could invalidate the certification, boiler warranty and mayalso infringe the current issue of the StatutoryRequirements. The requirements are: The installation of thisboiler must be carried out by a competent person inaccordance with the current rules in force in the countries ofdestination at the time of installation, for Ireland, install inaccordance with I.S.813 "Domestic Gas <strong>Installation</strong>".Manufacture's instructions supplied must not be taken asoverriding statutory requirements.CE MarkThis boiler meets the requirements of Statutory InstrumentNo. 3083 The boiler (Efficiency) Regulations, and therefore isdeemed to meet the requirements of Directive 92/42/EEC onthe efficiency requirements for new hot water boilers firedwith liquid or gaseous fuels.Type test for purposes of Regulation 5 certified by: Notifiedbody 0049.Product/production certified by: Notified body 0049.The CE mark on this appliance shows compliance with:1. Directive 90/396/EEC on the approximation of the laws ofthe Member States relating to appliances burninggaseous fuels.2. Directive 73/23/EEC on the harmonization of the Laws ofthe Member States relating to the electrical equipmentdesigned for use within certain voltage limits.3. Directive 89/336/EEC on the approximation of the Laws ofthe Member States relating to electromagnetic compatibility.Control of Substances Hazardous to HealthThe adhesives and sealants used in this appliance are curedand give no known hazard in this state.Insulation pads / ceramic fibreThese can cause irritation to skin, eyes and the respiratorytract.If you have a history of skin complaint you may be susceptibleto irritation. High dust levels are usual only if the materialis broken.Normal handling should not cause discomfort, but follownormal good hygiene and wash your hands before eating,drinking or going to the lavatory.If you do suffer irritation to the eyes or severe irritation to theskin seek medical attention.The insulation is composed of non-combustible material.Electrical SupplyWARNING: This boiler must be earthed.All system components shall be of an approved type and shallbe connected in accordance with the current issue of BS7671and any applicable local regulations.External wiring must be correctly earthed, polarised and inaccordance with the relevant standards.In GB this is BS 6891.In IE this is the current edition of I.S.813 "Domestic gasinstallation".Connection of the boiler and system controls to the mainssupply must be through a common isolator and must be fusedat 3A, maximum. This method of connection must be by a fuseddouble pole isolating switch, with a minimum contact separationof 3mm on both poles. The switch should be readily accessibleand preferably adjacent to the appliance. It should supply theappliance only and be easily identifiable as so doing.Alternatively, an unswitched shuttered socket outlet and 3Afused 3 pin plug, both to the current issue of BS1363 may beused provided that they are not used in a room containing a bathor shower.Wiring to the boiler must be PVC 85 o C insulated cable, not lessthan 0.75mm 2 (24/0.20mm).Manual Handling GuidanceDuring the appliance installation it will be necessary to employcaution and assistance whilst lifting as the appliance exceedsthe recommended weight for a one man lift.In certain situations it may be required to use a mechanicalhandling aid.Take care to avoid trip hazards, slippery or wet surfaces.Heating System ControlsThe heating system must be controlled as described in therelevant part of the current issue of :Building Regulations, approved document L1, and the references:1) GIL 59, 2000: Central heating system specification (CheSS)and2) GPG 302, 2001: Controls for domestic central heating systemand hot water. BRECSU.3) The domestic heating and hot water guide to the buildingregulations 2001.Thermostatic radiator valves may be installed, however theymust not be fitted in a room where the room thermostat islocated.Air in the heating systemPersistent air in the heating system may indicate leaks in thesystem or corrosion taking place. Call your <strong>Installation</strong>/Servicingcompany.Protection Against FreezingThe appliance has a built in frost protection programme as longas the electricity and gas are left switched on.This device operates the burner and system pump when thetemperature inside the boiler falls below 6 0 C.Any other exposed areas of the system should be protected bya separate frost thermostat.4000124050-24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!