6 Boiler Location, Flue and Ventilation6.1 Boiler LocationThe recommended clearances are shown in diagram 6.1.Note: The boiler must be mounted on a flat wall which issufficiently robust to take its weight when full. If in doubt, expertadvice should be obtained, in the event of the wall being foundnot suitable.The minimum acceptable spacings from the terminal toobstructions, other terminals and ventilation openings areshown in diagram 6.2. For Ireland the minimum distances forthe flue terminal positionning must be those detailed in I.S.813"Domestic Gas <strong>Installation</strong>s".The boiler must be installed so that the terminal is exposed tothe external air.6.2 Terminal guard, see diagram 6.3.A terminal guard is required if persons could come into contactwith the terminal or the terminal could be subject to damage.If a terminal guard is required, it must be positioned to providea minimum of 50mm clearance from any part of the terminaland to be central over the terminal.A suitable terminal guard type K3 can be supplied by:Tower flue components Ltd.Morley roadTonbridgeKentTN9 1RA6.3 Flue optionsThere are various flue systems to choose from as follows:Horizontal telescopic top flue pack.Horizontal top flue pack.Vertical flue pack.Twin flue pack.Extensions, 90° and 45° bends.For detailed information refer to flue options guide. This isavailable from your nearest stockist.6.4 Cupboard or compartment ventilationThe boiler can be fitted in a cupboard or compartment withoutthe need for permanent ventilation.11652*Note: It is permissible toinstall the boiler with smallerclearances than those quotedPROVIDING that considerationis given for Servicing/Repairs.25mmaboveelbow20mm* 5mm 600mm20mm* 450mm * 5mm300mmDiagram 6.1MINIMUM SITING DIMENSIONS FOR THEPOSITIONING OF FLUE TERMINALSMMHORIZONTAL FLUESA DIRECTLY BELOW, ABOVE ORHORIZONTALLY TO AN OPENING, AIR BRICK,OPENING WINDOWS, AIR VENT, OR ANYOTHER VENTILATION OPENING 300B BELOW GUTTER, DRAIN/SOIL PIPE 75C BELOW EAVES 200D BELOW A BALCONY OR CAR PORT 200E FROM VERTICAL DRAIN PIPES ANDSOIL PIPES 150F FROM INTERNAL/EXTERNAL CORNERSOR TO A BOUNDARY ALONGSIDE THETERMINAL 300G ABOVE ADJACENT GROUND ORBALCONY LEVEL 300H FROM SURFACE OR A BOUNDARYFACING THE TERMINAL 600I FACING TERMINALS 1200JFROM OPENING (DOOR/WINDOW)IN CAR PORT INTO DWELLING 1200K VERTICAL FROM A TERMINAL 1500L HORIZONTALLY FROM A TERMINAL 300VERTICAL FLUESM FROM ADJACENT WALL TO FLUE 300N FROM ANOTHER TERMINAL 600P FROM ADJACENT OPENING WINDOW 1000Q ABOVE ROOF LEVEL 300Diagram 6.211508Diagram 6.317 4000124050-2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!