Pre-operative actions1. Fit of the <strong>SurgiGuide</strong>Verify the fit of the <strong>SurgiGuide</strong> by carefully checking its position on a plaster model. Try toposition the <strong>SurgiGuide</strong> in the same way as the fit of the scan prosthesis on the model.Once the proper fit is determined, clinically evaluate the position and orientation of the drillingcylinders. During surgery, the cylinders within the <strong>SurgiGuide</strong> will transfer the pre-operativetreatment plan. It is therefore important to re-evaluate and confirm that your are satisfied withthe original pre-operative plan as well as its resulting transfer by the <strong>SurgiGuide</strong>.This visual inspection as well as the tactile sensation of determining the proper fit of the<strong>SurgiGuide</strong> on the model will facilitate the positioning of the <strong>SurgiGuide</strong> on the mucosa duringsurgery.Create a bite registration in an articulator to facilitate the repositioning of the <strong>SurgiGuide</strong> in themouth. To fixate the <strong>SurgiGuide</strong> during surgery, prepare the holes in the <strong>SurgiGuide</strong> atconvenient positions.2. Diameter of the cylindersConfirm the inner diameters of the drilling cylinders.Insert each drill, based on the requested drilling sequence, into the cylinders of thecustomized <strong>SurgiGuide</strong>.The inner diameters of the stainless steel cylinders are 0.1 to 0.3 mm larger than thediameters of the cutting surface of the drills.The deviation can be more significant when tapered/beveled drills are used.Note: If you decide to use a drill from a different implant manufacturer than that which youspecified in your <strong>SurgiGuide</strong> Order Form, be sure that it has the same diameter. Do NOT usea smaller diameter drill than specified for a drill guide cylinder as the angle deviation couldbecome unacceptably large.3. Decontamination / sterilizationDecontamination: use a disinfectant (i.e. chlorhexidine, betadine, etc.) or a sterilizing agentthat is approved for dental applications (check with the legal regulations in your country).Follow the recommendations of the manufacturer for disinfection or sterilization as you wouldfor other clinical devices.SURGICAL PROCEDURES<strong>SurgiGuide</strong> can be sterilized using γ-irradiation or EtO (conform EN552 and EN556respectively) or any other low temperature method (that conforms to the legal regulations inyour country). Do not autoclave or use any type of dry/steam heat sterilization.62www.SimPlant.com<strong>SurgiGuide</strong> <strong>Cookbook</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!