12.07.2015 Views

Installation Operation Maintenance

Installation Operation Maintenance

Installation Operation Maintenance

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General DataTable 4 - Water cooled units : CCUN High Efficiency (HE) - R407CCCUN CCUN CCUN CCUN CCUN CCUN CCUN205 HE 206 HE 207 HE 208 HE 209 HE 210 HE 211 HEEurovent Performances (1)Net Cooling Capacity (kW) 189.1 218.6 245.5 270.1 298.5 329.6 355.9Total Power input (kW) 39.0 44.5 49.5 55.7 61.4 69.0 77.6Evaporator Water pressure drop (kPa) 24 26 28 34 29 35 40Evaporator Head Pressure available (4) (kPa) 190 170 170 160 165 205 190Main Power supply 400/3/50Sound Power Level (4) (dBA) 85 84 86 85 87 87 87Sound Power Level w/ sound attenuation jacket4) (dBA) 80 79 81 80 81 81 81Units AmpsNominal (3) (A) 139 158 180 201 219 246 268Start-up AmpsStandard Unit (A) 308 345 405 426 449 508 530With soft starter option (A) 229 255 296 317 335 380 402Short circuit unit capacity (kA) 15 15 15 15 15 15 15Max supply cable size (mm²) 95 95 150 150 150 150 150Min supply cable size (mm²) 35 35 50 50 70 70 95CompressorNumber 4TypeScrollModel (15T+15T) (15T+20T) (15T+25T) (20T+25T) (25T+25T) (25T+30T) (30T+30T)Number of speeds 1 1 1 1 1 1 1Number of motors 1 1 1 1 1 1 1Rated Amps (Comp A / Comp B)(3) (A) 32/32 32/40 32/52 40/52 52/52 52/62 62/62Locked rotor Amps (Comp A / Comp B) (A) 198/198 198/225 198/272 225/272 272/272 272/320 320/320Motor RPM (rpm) 2900 2900 2900 2900 2900 2900 2900Power factor (Comp A / Comp B) 0.89/0.89 0.89/0.91 0.89/0.87 0.91/0.87 0.87/0.87 0.87/0.87 0.87/0.87Sump Heater (Comp A / Comp B) (W) 70/70 70/120 70/150 120/150 150/150 150/150 150/150EvaporatorNumber 1TypeBrazed plateModel DV58-138 DV58-154 DV58-170 DV58-170 DV58-214 DV58-214 DV58-214Water volume (total) (l) 29.0 32.4 35.7 35.7 45.0 45.0 45.0Antifreeze Heater (W) noEvaporator Water ConnectionsVictaulicDiameter 3"Max. water-side operating pressure.without hydraulic module (kPa) 1200 1200 1200 1200 1200 1200 1200with hydraulic module (kPa) 400 400 400 400 400 400 400Remote condenser connectionsDischarge line diameter circuit 1 & 2 1"5/8Liquid line diameter circuit 1 & 2 1"1/8DimensionsHeight (mm) 1842Length (mm) 2520Width (mm) 880Operating WeightBase Unit (kg) 1180 1240 1300 1390 1480 1550 1620Evap Hyd Kit (kg) 1270 1330 1470 1560 1650 1720 1790Shipping WeightBase Unit (kg) 1120 1170 1210 1300 1380 1450 1520Evap Hyd Kit (kg) 1210 1260 1380 1470 1550 1620 1690System DataNumber of refrigerant circuit 2Capacity steps 4 4 4 4 4 4 4Minimum capacity (%) 25 21 18 22 25 23 25Refrigerant Charge (2)Circuit A & B (kg) Holding chargeOil Charge (2)Circuit A & B (l) 8.2 8.8 10.4 11.0 12.6 12.6 12.6(1) at Eurovent Conditions (Evap 12°C/7°C - Condenser. 30°C/35°C)(2) per circuit(3) Max rated conditions.(4) Dual Pump OptionCG-SVX06A-E47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!