General DataTable 3 - Water cooled units : CCUN standard - R407CCCUN CCUN CCUN CCUN CCUN CCUN CCUN205 206 207 208 209 210 211Eurovent Performances (1)Net Cooling Capacity (kW) 181.5 196.0 237.5 262.9 291.7 321.0 349.1Total Power input (kW) 40.3 45.7 51.0 57.4 63.0 70.0 78.4Evaporator Water pressure drop (kPa) 55 57 58 55 54 54 55Evaporator Head Pressure available (4) (kPa) 170 150 150 145 140 185 180Main Power supply 400/3/50Sound Power Level (4) (dBA) 85 84 86 85 87 87 87Sound Power Level w/ sound attenuation jacket (4) (dBA) 80 79 81 80 81 81 81Units AmpsNominal (3) (A) 139 158 180 201 219 246 268Start-up AmpsStandard Unit (A) 308 345 405 426 449 508 530With soft starter option (A) 229 255 296 317 335 380 402Short circuit unit capacity (kA) 15 15 15 15 15 15 15Max supply cable size (mm²) 95 95 150 150 150 150 150Min supply cable size (mm²) 35 35 50 50 70 70 95CompressorNumber 4TypeScrollModel (15T+15T) (15T+20T) (15T+25T) (20T+25T) (25T+25T) (25T+30T) (30T+30T)Number of speeds 1 1 1 1 1 1 1Number of motors 1 1 1 1 1 1 1Rated Amps (Comp A / Comp B) (3) (A) 32/32 32/40 32/52 40/52 52/52 52/62 62/62Locked rotor Amps (Comp A / Comp B) (A) 198/198 198/225 198/272 225/272 272/272 272/320 320/320Motor RPM (rpm) 2900 2900 2900 2900 2900 2900 2900Power factor (Comp A / Comp B) 0.89/0.89 0.89/0.91 0.89/0.87 0.91/0.87 0.87/0.87 0.87/0.87 0.87/0.87Sump Heater (Comp A / Comp B) (W) 70/70 70/120 70/150 120/150 150/150 150/150 150/150EvaporatorNumber 1TypeBrazed plateModel DV58-82 DV58-94 DV58-106 DV58-122 DV58-138 DV58-154 DV58-170Water volume (total) (l) 17.2 19.7 22.2 25.6 29.0 32.4 35.7Antifreeze Heater (W) noEvaporator Water ConnectionsVictaulic MaleDiameter 3"Max. water-side operating pressure.without hydraulic module (kPa) 1200 1200 1200 1200 1200 1200 1200with hydraulic module (kPa) 400 400 400 400 400 400 400Remote condenser connectionsDischarge line diameter circuit 1 & 2 1"5/8Liquid line diameter circuit 1 & 2 1"1/8DimensionsHeight (mm) 1842Length (mm) 2520Width (mm) 880Operating WeightBase Unit (kg) 1120 1170 1300 1370 1420 1510 1590Evap Hyd Kit (kg) 1210 1260 1470 1540 1590 1680 1760Shipping WeightBase Unit (kg) 1070 1120 1230 1290 1340 1430 1500Evap Hyd Kit (kg) 1160 1210 1400 1460 1510 1600 1670System DataNumber of refrigerant circuit 2Capacity steps 4 4 4 4 4 4 4Minimum capacity (%) 25 21 18 22 25 23 25Refrigerant Charge (2)Circuit A & B (kg) Holding chargeOil Charge (2)Circuit A & B (l) 8.2 8.8 10.4 11.0 12.6 12.6 12.6(1) at Eurovent Conditions (Evap 12°C/7°C - Condenser. 30°C/35°C)(2) per circuit(3) Max rated conditions.(4) Dual Pump Option6CG-SVX06A-E4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!