General DataTable 2 - Water cooled units : CGWN High Efficiency (HE) - R407CCGWN CGWN CGWN CGWN CGWN CGWN CGWN205 HE 206 HE 207 HE 208 HE 209 HE 210 HE 211 HEEurovent Performances (1)Net Cooling Capacity (kW) 187.4 216.6 243.4 267.8 295.7 326.2 351.7Total Power input (kW) 39.2 44.9 51.4 58.0 64.2 72.7 82.3Evaporator Water pressure drop (kPa) 24 26 28 33 28 34 39Evaporator Head Pressure available (4) (kPa) 190 170 170 160 165 205 190Condenser Water pressure drop (kPa) 26 29 26 30 37 45 52Condenser Head Pressure available (kPa) 180 170 190 180 170 160 140Main Power supply 400/3/50Sound Power Level (4) (dBA) 85 84 86 85 87 87 87Sound Power Level w/ sound attenuation jacket (4) (dBA) 80 79 81 80 81 81 81Units AmpsNominal (3) (A) 139 158 180 201 219 246 268Start-up AmpsStandard Unit (A) 308 345 405 426 449 508 530With soft starter option (A) 229 255 296 317 335 380 402Short circuit unit capacity (kA) 15 15 15 15 15 15 15Max supply cable size (mm²) 95 95 150 150 150 150 150Min supply cable size (mm²) 35 35 50 50 70 70 95CompressorNumber 4TypeScrollModel (15T+15T) (15T+20T) (15T+25T) (20T+25T) (25T+25T) (25T+30T) (30T+30T)Number of speeds 1 1 1 1 1 1 1Number of motors 1 1 1 1 1 1 1Rated Amps (Comp A / Comp B) (3) (A) 32/32 32/40 32/52 40/52 52/52 52/62 62/62Locked rotor Amps (Comp A / Comp B) (A) 198/198 198/225 198/272 225/272 272/272 272/320 320/320Motor RPM (rpm) 2900 2900 2900 2900 2900 2900 2900Power factor (Comp A / Comp B) 0.89/0.89 0.89/0.91 0.89/0.87 0.91/0.87 0.87/0.87 0.87/0.87 0.87/0.87Sump Heater (Comp A / Comp B) (W) 70/70 70/120 70/150 120/150 150/150 150/150 150/150EvaporatorNumber 1TypeBrazed plateModel DV58-138 DV58-154 DV58-170 DV58-170 DV58-214 DV58-214 DV58-214Water volume (total) (l) 29.0 32.4 35.7 35.7 45.0 45.0 45.0Antifreeze Heater (W) noEvaporator Water ConnectionsVictaulicDiameter 3"Max. water-side operating pressure.without hydraulic module (kPa) 1200 1200 1200 1200 1200 1200 1200with hydraulic module (kPa) 400 400 400 400 400 400 400CondenserNumber 1TypeBrazed plateModel DV58-154 DV58-170 DV58-202 DV58-202 DV58-222 DV58-222 DV58-222Water volume (total) (l) 32.4 35.7 42.4 42.4 46.7 46.7 46.7Condenser Water ConnectionsVictaulicDiameter 3"Max. water-side operating pressure.without hydraulic module (kPa) 1200 1200 1200 1200 1200 1200 1200with hydraulic module suction/discharge (kPa) 400/640 400/640 400/640 400/640 400/640 400/640 400/640DimensionsHeight (mm) 1842Length (mm) 2520Width (mm) 880Operating WeightBase Unit (kg) 1320 1470 1540 1630 1730 1800 1870Evap Hydraulic Kit (kg) 1410 1560 1710 1800 1900 1970 2040Evap + Cds Hydraulic Kit (kg) 1480 1630 1810 1900 2000 2070 2140Shipping WeightBase Unit (kg) 1220 1370 1410 1500 1590 1660 1730Evap Hydraulic Kit (kg) 1310 1460 1580 1670 1760 1830 1900Evap + Cds Hydraulic Kit (kg) 1380 1530 1680 1770 1860 1930 2000System DataNumber of refrigerant circuit 2Capacity steps 4 6 6 6 4 6 4Minimum capacity (%) 25 21.4 18.8 22.2 25 22.7 25Refrigerant Charge (2)Circuit A & B (kg) 14 15 17 17 19 19 19Oil Charge (2)Circuit A & B (l) 8.2 8.8 10.4 11.0 12.6 12.6 12.6(1) at Eurovent Conditions (Evap 12°C/7°C - Condenser. 30°C/35°C)(2) per circuit(3) Max rated conditions(4) Dual Pump OptionCG-SVX06A-E45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!