12.07.2015 Views

LM Guide THK - Industrial Technologies

LM Guide THK - Industrial Technologies

LM Guide THK - Industrial Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Индастриал Технолоджис www.industrial‐technologies.com.ua +38 044 498 21 94[Combined Radial And Thrust Load]• During AscentPEu1 = | Pu1 | + | Ptu1 | = 1731.3 NPEu2 = | Pu2 | + | Ptu2 | = 1731.3 NPEu3 = | Pu3 | + | Ptu3 | = 1731.3 NPEu4 = | Pu4 | + | Ptu4 | = 1731.3 N• During DescentPEd1 = | Pd1 | + | Ptd1 | = 1143.3 NPEd2 = | Pd2 | + | Ptd2 | = 1143.3 NPEd3 = | Pd3 | + | Ptd3 | = 1143.3 NPEd4 = | Pd4 | + | Ptd4 | = 1143.3 N[Static Safety Factor]The static safety factor (fS) of the <strong>LM</strong> <strong>Guide</strong> used in a machine or equipment under the conditionsstated above is obtained as follows.fSC0 34.410 3= == 19.9PEu2 1731.3[Average Load Pmn]Obtain the average load applied to each <strong>LM</strong> block.Pm1 =31(PEU1 3 •l S + PEd1 3 •l S) = 1495.1 N2•l SPm2 =31(PEU2 3 •l S + PEd2 3 •l S) = 1495.1 N2•l SPm3 =31(PEU3 3 •l S + PEd3 3 •l S) = 1495.1 N2•l SPm4 =31(PEU4 3 •l S + PEd4 3 •l S) = 1495.1 N2•l S[Nominal Life Ln]The nominal life of the four <strong>LM</strong> blocks is obtained from the corresponding nominal life equationsshown below. • • • • (where f w = 1.2)Therefore, the service life of the <strong>LM</strong> <strong>Guide</strong> used in a machine or equipment under the conditionsstated above is 68,200 km.<strong>Industrial</strong> <strong>Technologies</strong>A1-86