Typical Raceway configurations:<br />
Virtually any electrical layout can be realized by utilizing the power infeed leg, proper lengths of raceway and jumper cables. Raceways provide combinations of<br />
duplex power outlets and duplex communications outlets. The length of the table top defines the length of the raceway.<br />
90� Desking configuration:<br />
Consists of a power infeed leg, a long and<br />
short raceway and 2 jumper cables<br />
Linear computer training configuration:<br />
Consists of a power infeed leg, 2 raceways of equal length<br />
mounted at front of desk, and 2 jumper cables. This configuration<br />
may be extended to incorporate any number of desks.<br />
Specifications<br />
Raceway:<br />
All raceways include a pre-installed<br />
power rail that fits 2 duplex outlets.<br />
The 20�,26�,38�long raceway also<br />
has pre-cut holes for installation of<br />
two double communication outlets.<br />
Raceways ship with special locking<br />
connectors for permanently ganging<br />
tables.<br />
Communication wiring has to be<br />
field installed by communication<br />
contractor.<br />
Raceway kits do not include wire<br />
management trough for surplus<br />
wires. Specify P4-WMT or P4-AWB<br />
for storage of surplus wires.<br />
Note: all tables must be ganged<br />
permanently with electrical<br />
connectors when Raceway Kit is<br />
used.<br />
Duplex outlets:<br />
Duplex outlet circuits are<br />
designated by white letters on black<br />
background. Two duplex outlets<br />
marked for a specific circuit can be<br />
specified. Choose none, one or two<br />
duplex outlets per raceway. Each<br />
raceway kit can receive two duplex<br />
outlets of the same or of different<br />
circuits.<br />
Communications modules:<br />
AMP outlet faceplates have black<br />
textured finish. A maximum of two<br />
double communications outlets can<br />
be specified for different wiring and<br />
standards. AMP RJ45 outlets are<br />
available with EIA-T568B (ATT<br />
wiring) or EIA-T568A (all other EIA<br />
wiring) configurations. All RJ45<br />
communications outlets are<br />
specially configured and rated for<br />
359<br />
Cluster configuration:<br />
Consists of a power infeed leg of 4 short and long raceways connected by 8<br />
jumper cables.<br />
Curved training configuration:<br />
Consists of a power infeed leg, 3 raceways of equal length mounted at<br />
mid-depth of desk, and 3 jumper cables.<br />
Category 5 high speed data cabling,<br />
except those with couplers (Cat 3).<br />
For more communications module<br />
options, consult the Currents<br />
pricelist.<br />
Jumper cables:<br />
Jumper cables connect power from<br />
raceway to raceway, bridging<br />
between tables. They consist of<br />
electrical conduit encased in a<br />
flexible metal tube with electrical<br />
connectors on both ends. Different<br />
length jumper cables are required<br />
depending on the configuration.<br />
<strong>Knoll</strong>Studio<br />
Pre-wired, power infeed leg:<br />
Pre-wired, power infeed leg supplies<br />
raceway with power from building<br />
power source. Extruded aluminum<br />
with anodized or powder coat finish.<br />
One section of the leg is fully<br />
enclosed for electrical wiring, the<br />
other has a clear, flexible PVC strip<br />
to lay in data cables.<br />
A91 /4� long cable emanating from<br />
top of leg is used to connect power<br />
infeed leg to raceway. 6’ conduit<br />
emanating from bottom of leg is<br />
used for hard-wiring leg to building<br />
power. This can be cut to length<br />
during installation.<br />
Specify left leg if infeed is located<br />
left of raceway, right leg if infeed is<br />
located right of raceway. Installation<br />
by licensed electrician only.