Typical Raceway configurations:<br />

Virtually any electrical layout can be realized by utilizing the power infeed leg, proper lengths of raceway and jumper cables. Raceways provide combinations of<br />

duplex power outlets and duplex communications outlets. The length of the table top defines the length of the raceway.<br />

90� Desking configuration:<br />

Consists of a power infeed leg, a long and<br />

short raceway and 2 jumper cables<br />

Linear computer training configuration:<br />

Consists of a power infeed leg, 2 raceways of equal length<br />

mounted at front of desk, and 2 jumper cables. This configuration<br />

may be extended to incorporate any number of desks.<br />

Specifications<br />

Raceway:<br />

All raceways include a pre-installed<br />

power rail that fits 2 duplex outlets.<br />

The 20�,26�,38�long raceway also<br />

has pre-cut holes for installation of<br />

two double communication outlets.<br />

Raceways ship with special locking<br />

connectors for permanently ganging<br />

tables.<br />

Communication wiring has to be<br />

field installed by communication<br />

contractor.<br />

Raceway kits do not include wire<br />

management trough for surplus<br />

wires. Specify P4-WMT or P4-AWB<br />

for storage of surplus wires.<br />

Note: all tables must be ganged<br />

permanently with electrical<br />

connectors when Raceway Kit is<br />

used.<br />

Duplex outlets:<br />

Duplex outlet circuits are<br />

designated by white letters on black<br />

background. Two duplex outlets<br />

marked for a specific circuit can be<br />

specified. Choose none, one or two<br />

duplex outlets per raceway. Each<br />

raceway kit can receive two duplex<br />

outlets of the same or of different<br />

circuits.<br />

Communications modules:<br />

AMP outlet faceplates have black<br />

textured finish. A maximum of two<br />

double communications outlets can<br />

be specified for different wiring and<br />

standards. AMP RJ45 outlets are<br />

available with EIA-T568B (ATT<br />

wiring) or EIA-T568A (all other EIA<br />

wiring) configurations. All RJ45<br />

communications outlets are<br />

specially configured and rated for<br />

359<br />

Cluster configuration:<br />

Consists of a power infeed leg of 4 short and long raceways connected by 8<br />

jumper cables.<br />

Curved training configuration:<br />

Consists of a power infeed leg, 3 raceways of equal length mounted at<br />

mid-depth of desk, and 3 jumper cables.<br />

Category 5 high speed data cabling,<br />

except those with couplers (Cat 3).<br />

For more communications module<br />

options, consult the Currents<br />

pricelist.<br />

Jumper cables:<br />

Jumper cables connect power from<br />

raceway to raceway, bridging<br />

between tables. They consist of<br />

electrical conduit encased in a<br />

flexible metal tube with electrical<br />

connectors on both ends. Different<br />

length jumper cables are required<br />

depending on the configuration.<br />

<strong>Knoll</strong>Studio<br />

Pre-wired, power infeed leg:<br />

Pre-wired, power infeed leg supplies<br />

raceway with power from building<br />

power source. Extruded aluminum<br />

with anodized or powder coat finish.<br />

One section of the leg is fully<br />

enclosed for electrical wiring, the<br />

other has a clear, flexible PVC strip<br />

to lay in data cables.<br />

A91 /4� long cable emanating from<br />

top of leg is used to connect power<br />

infeed leg to raceway. 6’ conduit<br />

emanating from bottom of leg is<br />

used for hard-wiring leg to building<br />

power. This can be cut to length<br />

during installation.<br />

Specify left leg if infeed is located<br />

left of raceway, right leg if infeed is<br />

located right of raceway. Installation<br />

by licensed electrician only.