Emanuela Frattini<br />

Propeller� Electrical<br />

2+2 Raceway Kit Electrical options for Training and Conference<br />

tables<br />

The Propeller raceway kit is used when a permanent configuration with rectangular and trapezoid training tables is specified. Typical examples for such<br />

situations are desk configurations, cluster desk configurations, computer training room setups. The raceway kit offers permanent power and communication<br />

outlets accessible from underneath the top. Access to these outlets is provided through grommets in the table. Quadruplex or transact outlets may also bring<br />

the wiring up to the table top.<br />

Raceway kit components<br />

The Propeller Raceway kit is comprised of three components:<br />

Infeed leg, Raceway, Jumper cable and the power and<br />

communications outlets.<br />

Power infeed legs:<br />

Provides permanent power and communications access. Alternatively empty infeed legs can also be specified.<br />

Raceway compatible with legs shown below.<br />

Ordering Information<br />

Specify:<br />

1. Suitable raceway for every table<br />

2. Jumper cables for every<br />

table-to-table connection.<br />

3. Power infeed leg<br />

4. Power infeed leg finish<br />

5. Power and communications<br />

outlets<br />

Description<br />

Raceway kit:<br />

The2+2Raceway kit is a<br />

four-circuit, eight-wire modular<br />

power distribution system available<br />

for all <strong>Knoll</strong> systems. Raceway<br />

components distribute two 20 amp<br />

convenience circuits (A,B) with<br />

shared neutral and ground and two<br />

surge protected 20 amp circuits (X,<br />

Y) with separate neutral and<br />

ground. Each raceway has four<br />

connectors for jumper cables, two<br />

on left and two on the right. This<br />

allows for configurations with<br />

branching side connections from the<br />

overall circuit.<br />

Raceway:<br />

Raceways are available in various different lengths. All raceways offer room for<br />

two duplex power outlets with surge protection. The 20�,26�,38� long raceway<br />

also has pre-cut holes for installation of two double communication outlets.<br />

Raceways are compatible with training and trapezoid tables and can be located<br />

in the front of mid-depth positions of all tables, and also at the back of the<br />

trapezoid table.<br />

Jumper cables:<br />

There are two types of jumper cables. Male-Female jumper cables are used to<br />

connect power infeed legs to the first plexus box or first raceway. Male-male<br />

jumper cables are used to connect between plexus boxes or between raceways.<br />

358<br />

A complete Raceway Kit consists of:<br />

- Pre-assembled Raceway mounted<br />

inside metal trough. One raceway<br />

per table required.<br />

- Jumper cables for bridging power<br />

between raceways on ganged tables.<br />

- Power infeed legs bring power<br />

from building power to raceway.<br />

Construction<br />

Raceway:<br />

Bent sheet metal trough with dark<br />

grey finish. Raceway is fully<br />

enclosed in metal trough.<br />

Jumper cables:<br />

Electrical conduit encased in a<br />

flexible metal tube with electrical<br />

connectors on both ends.<br />

Power infeed leg:<br />

Extruded aluminum leg with glide<br />

and cast aluminum end plate or cast<br />

aluminum foot for C-legs or T-legs<br />

Wiring is shielded inside fully<br />

enclosed leg section. 6’ conduit<br />

emanating from bottom of leg for<br />

connection to building power. 9 1 /4�<br />

long jumper cable emanating from<br />

top of leg is used to connect power<br />

infeed leg to raceway.