Plexus Box Connectivity options:<br />

Plexus Boxes are available with three connectivity options for either temporary or permanent installation.<br />

Plexus Box with Cordset For temporary power and communications access.<br />

P4( )-BOX( )-PP<br />

Use existing leg.<br />

Empty Plexus Box For hard-wired power and communications access. Compatible with legs shown below.<br />

P4( )-BOX( )-E<br />

Training leg<br />

Conference leg<br />

P4-RWIN4-RE (right) P3-CLEG-PE<br />

P4-RWIN4-LE (left)<br />

Trapezoid leg<br />

P4-RWIN4-TE<br />

C-Leg<br />

P4-RWIN4-CRE (right)<br />

P4-RWIN4-CLE (left)<br />

Pre-wired Plexus Box For permanent power and communications access. Compatible with legs shown below.<br />

P4( )-BOX( )-PR<br />

Connectivity<br />

Plexus Box with Cordset:<br />

The Plexus Box with Cordset offers<br />

temporary power and<br />

communications access, comprising<br />

a single electrical circuit with a<br />

3-prong plug. The 15’ cable can<br />

simply be channeled through the<br />

Propeller leg to connect to standard<br />

floor or wall outlets. Leg that is<br />

shipped with the Propeller table is<br />

used with the Plexus box with<br />

Cordset.<br />

Plexus Boxes with Cordset simply<br />

rest in the table cutout. Do not<br />

attach permanently to the table to<br />

comply with UL requirements. This<br />

option is not available for New York<br />

and Chicago.<br />

Training leg<br />

P4-RWIN4-R (right)<br />

P4-RWIN4-L (left)<br />

Conference leg<br />

P3-CLEG-PR<br />

Empty Plexus Boxes for hardwiring:<br />

The empty Plexus Box for<br />

hardwiring offers permanent power<br />

and data access and has room for<br />

wiring up to four-circuits. A special<br />

empty infeed leg (E) must be<br />

specified to bring wires from<br />

building power supply to first empty<br />

Plexus Box. Suitable for all regions.<br />

Pre-wired Plexus Boxes:<br />

The Pre-wired Plexus Box offers<br />

permanent power and data access.<br />

A special Pre-wired infeed leg (R)<br />

must be specified to bring wires<br />

from building power supply to first<br />

pre-wired Plexus Box.<br />

Jumper cables connect individual<br />

pre-wired Plexus Boxes together<br />

and connect the first plexus Box to a<br />

pre-wired infeed leg. Suitable for<br />

most regions if connected to<br />

building power by licensed<br />

electrician.<br />

Trapezoid leg<br />

P4-RWIN4-T<br />

345<br />

Construction<br />

T-Leg<br />

P3-TLEGU-PE<br />

C-Leg<br />

P4-RWIN4-CR (right)<br />

P4-RWIN4-CL (left)<br />

Empty Plexus boxes attach to table<br />

via clamps from underneath the<br />

table top. Pre-wired and Cordset<br />

Plexus Boxes simply rest in the<br />

table cutout. Accomodates table<br />

thickness from 1� to 1 1 /2�.<br />

T-Leg<br />

P3-TLEGU-PR<br />

Cutout options<br />

<strong>Knoll</strong>Studio<br />

Plexus cutout locations:<br />

For cutout locations see chart on<br />

specific product pages. Boxes ship<br />

with actual cutout template in case<br />

cutouts need to be done in the field.