HIMax Safety Manual - Tuv-fs.com

HIMax Safety Manual - Tuv-fs.com

HIMax Safety Manual - Tuv-fs.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HIMax</strong>9 SoftwareParameter / Switch Function DefaultsettingSetting forsafe operationName Resource name - ArbitrarySystem ID [SRS] System ID of the resource1...65 53560 000Unique value withinthe controller network.This network includesall controllers that canpotentially beinterconnected<strong>Safety</strong> time [ms] <strong>Safety</strong> time in milliseconds20...100 000600 Application-specificWatchdog time [ms] Watchdog time in milliseconds2...50 000 ms200 Application-specificMain Enable The following switches/parameters can beONchanged during operation (= RUN) using theOFF is re<strong>com</strong>mendedPADT. When OFF, the parameters are"frozen“ as they areAutostartAutomatic start allowed after Power ON of OFFCPUApplication-specificStart Allowed A cold start, warm start or hot start permitted ONwith the PADT in RUN or STOPApplication-specificLoading allowed Load of the user program permitted ON Application-specificReload Allowed Release to reload of a user program. Thereload process currently running is not ON Application-specificaborted when switching to OFFGlobal ForcingAllowedReleases global forcing for this resource OFF Application-specificGlobal Force TimeoutReactionMax.Com. Time SliceASYNC [ms]Determines how the resource should behaveon expiry of the global force time-out: Onlystop forcing, Stop resourceHighest value in ms for the time slice usedfor <strong>com</strong>munication,2...5000 msTable 13: System Parameters of the ResourceOnly stopforcingApplication-specific10 Application-specific9.4.2 Hardware System VariablesThese variables are used to change the behavior of the controller during operation inspecific states. These variables can be set in the detailed view of the hardware, in theSILworX Hardware Editor.Parameter / Switch Function DefaultsettingSetting forsafe operationForce Deactivation Used to prevent forcing and to stop itimmediatelyOFF Application-specificEmpty 0 ... Empty 16 No function - -Emergency Stop 1 ...Emergency Stop 4Read-only in RUNEmergency stop switch to shutdown thecontroller if faults are detected by the userprogramWith the exception of forcing and reload, it isnot possible to perform any operations (stop,start, download) with SILworXOFFOFFReload deactivation Prevents execution of reload OFFTable 14: Hardware System VariablesApplication-specificApplication-specificApplication-specificGlobal variables can be assigned to these system variables; the value of the globalvariables is modified using a physical input or the user program logic.HI 801 003 D Rev.2.0 Page 49 of 70

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!