12.07.2015 Views

LT-2020 MR-2944 Installation and Operation Manual Rev.1 - Secutron

LT-2020 MR-2944 Installation and Operation Manual Rev.1 - Secutron

LT-2020 MR-2944 Installation and Operation Manual Rev.1 - Secutron

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MR</strong>-<strong>2944</strong> <strong>Installation</strong> <strong>and</strong> Operator’s <strong>Manual</strong>1.0 Technical Information1.1 GeneralThe <strong>MR</strong>-<strong>2944</strong> Annunciator Driver is capable of controlling up to 576 LEDs, as 192 zones of 3LEDs each (Alarm, Supervisory, Trouble), for use with columnar or graphic annunciators. Twooptional LCD displays are available, an 80 character (4 x 20) display the same size as the <strong>MR</strong>-2900 LCD display <strong>and</strong> a larger display twice that size. Both can be used to display text messages.The <strong>MR</strong>-<strong>2944</strong> uses the <strong>MR</strong>-2910 Network Communications Board for network interface. The <strong>MR</strong>-<strong>2944</strong> can use all variants of the <strong>MR</strong>-2910 board. The <strong>MR</strong>-<strong>2944</strong> may also use the <strong>MR</strong>-D1010RFiber Optic Modem for connecting a fiber network between panels.The <strong>MR</strong>-<strong>2944</strong> uses the AN4 program for connection to <strong>MR</strong>-2900 <strong>and</strong> <strong>MR</strong>-2100/2200 networks <strong>and</strong>the AN4A program for connection to <strong>MR</strong>-2400 panels. All programs are nearly identical inoperation, but the AN4A program may not be used to create a fiber optic network.The LEDs are interfaced to the Annunciator Driver using the <strong>MR</strong>-2902 Annunciator Strip, the <strong>MR</strong>-2622 Annunciator Strip or the <strong>MR</strong>-2915 LED Driver.Communication to the <strong>MR</strong>-2900 Control Unit is over a proprietary DCLR (Style 7) network. Thereare two communications ports (COM1 <strong>and</strong> COM2). These ports are identical to the network portson the <strong>MR</strong>-2900 Control Unit. Wiring for st<strong>and</strong>ard network communications is not polaritysensitive. RS-232 network communications is polarity sensitive.There are two versions of annunciator enclosures:• <strong>MR</strong>-<strong>2944</strong>, the annunciator board enclosed in cabinet (not applicable for ULC installationfor annunciator application• <strong>MR</strong>-<strong>2944</strong>-ANN, the annunciator board on mounting chassis. The <strong>MR</strong>-<strong>2944</strong>-ANN may beenclosed in the <strong>MR</strong>-<strong>2944</strong>-BBS 4 LED strip or <strong>MR</strong>-<strong>2944</strong>-BBL 8 LED strip annunciatorenclosures or, when used for graphic displays, may be enclosed in the custom graphicannunciator.1.2 <strong>MR</strong>-2915 LED DriverThe <strong>MR</strong>-2915 Graphic LED Driver drives up to 24 LEDs. There is a 50 pin connector to which theLEDs of a pre-designed custom graphic LED display are attached.1.3 <strong>MR</strong>-2902 Annunciator StripThe Annunciator Strip contains 24 sets of zone indicating LEDs. Individual LEDs are provided todisplay alarm, supervisory <strong>and</strong> trouble conditions by zone. The LED functions, from the left, are:Alarm (red), Supervisory (yellow or amber) <strong>and</strong> Trouble (yellow).1.3.1 <strong>MR</strong>-2902-ANN St<strong>and</strong>ard Strip complete with mounting bracketThe Annunciator Strip contains 24 sets of zone indicating LEDs. Individual LEDs are provided todisplay alarm, supervisory <strong>and</strong> trouble conditions by zone. The LED functions, from the left, are:Alarm (red), Supervisory (yellow or amber) <strong>and</strong> Trouble (yellow).1.3.2 <strong>MR</strong>-2902-ANN-HTLD Common Indicator Strip complete with mountingbracketSimilar to <strong>MR</strong>-2902 except Zones 21 to 24 reserved for LED annunciation of FACU commonindicators.Strip to be installed in annunciator back boxes <strong>MR</strong>-<strong>2944</strong>-BBS or <strong>MR</strong>-<strong>2944</strong>-BBL. Special MHIconfiguration is needed to map the Fire Alarm Control Unit common indicators to the reserved <strong>MR</strong>-2902-HTLD zones.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!