<strong>MR</strong>-<strong>2944</strong> <strong>Installation</strong> <strong>and</strong> Operator’s <strong>Manual</strong><strong>MR</strong>-2622 Jumper SettingsThe <strong>MR</strong>-2622 is an 8 zone LED strip <strong>and</strong> can be configured to display one of zone groups 1-8, 9-16 or 17-24. The jumper for setting the displayed zone group is located just below the ribbon cableconnector (see Figure 9 - <strong>MR</strong>-2622 8 Zone LED Annunciator on page 8).The unit is shipped withthe default setting to display zone group 1 to 8. To change the zone group, cut the trace on thebottom of the board that is shorting the zone group 1-8 pins <strong>and</strong> move the jumper to the requiredzone group.Ribbon CableJumper HolesZone group 17-24Zone group 9-16Zone group 1-8Trace Setting(On back of board)Zone group 1-8DefaultComponentSideFigure 9 - <strong>MR</strong>-2622 8 ZoneLED AnnunciatorFigure 10 - <strong>MR</strong>-2915 LED Pinouts8