®ELABOTrainingsSysteme


Electrical MachinesOther voltages <strong>and</strong> frequencies on request!57 109 V ariable Compound Wound DC MachineThree-phase induction motor 0.25 kW57 100Circuit typestar/deltaVoltage692/400 V ACFrequency50 HzSpeed1500 rpmThree-phase induction motor 0.18 /0.25 kW57 101Circuit typeDahl<strong>and</strong>erVoltage400 V ACFrequency50 HzSpeed1500/3000 rpmThree-phase induction motor 0.25 kW57 102Circuit typeslipring rotorVoltage400 V ACFrequency50 HzSpeed1500 rpmThree-phase induction motor 0.12 /0.25 kW57 103Circuit typeseparatewindingsVoltage400 V ACFrequency50 HzSpeed750/1500 rpmThree-phase induction motor 0.25 kW57 104Circuit typestar/deltaVoltage400/<strong>230</strong> V ACFrequency50 HzSpeed1500 rpmThree-phase induction motor 0.25 kW,with EMC-compliant connection cable,for operation with a frequency converter57 105Circuit typeVoltageFrequencySpeedstar/delta400/<strong>230</strong> V AC50 Hz1500 rpmSeries-wound DC machine 0.3 kW57 106VoltageSpeed205 V DC2000 rpmShunt-wound DC machine 0.3kW57 107VoltageSpeed205 V DC2000 rpmCompound-wound DC machine 0.3kW57 108VoltageSpeed220 V DC1500 rpmVariable compound-wound DC machine 0.3 kW57 109VoltageSpeed205 V DC2000 rpmUniversal motor AC/DC 0.2 kW57 110DC voltageAC voltageSpeedSynchronous machineSmooth-core rotor 0.3 kW57 111Circuit typeVoltageFrequency140 V DC<strong>230</strong> V AC / 50 Hz3000 rpmstar/delta400/<strong>230</strong> V AC50 HzSynchronous machineSalient-pole rotor 0.3 kW57 112VoltageFrequencySpeed400 V AC50 Hz1500 rpmMultifunction machine 0.27 kWSlipring rotor, synchronizable57 113Circuit typeVoltageFrequencystar/delta400/<strong>230</strong> V AC50 HzThree-phase reluctance motor 0.25 kW57 114Circuit typeVoltageFrequencySpeedRepulsion motor 0.25 kW57 115VoltageFrequencySpeedSingle-phase motor 0.18 kWwith running capacitor57 116VoltageFrequencySpeedstar/delta400/<strong>230</strong> V AC50 Hz1500 rpm<strong>230</strong> V AC50 Hz2100 rpm<strong>230</strong> V AC50 Hz1500 rpmSingle-phase motor 0.25 kWwith starting <strong>and</strong> running capacitor57 117VoltageFrequencySpeed<strong>230</strong> V AC50 Hz1500 rpm6


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> <strong>230</strong> V<strong>Control</strong> Board IILearning Objectives: Basic circuits with series circuits, parallel circuits, self-holding function<strong>and</strong> lock Applied circuits with star/delta start, reversing, Dahl<strong>and</strong>er<strong>and</strong> step circuit functions Arrangement of main <strong>and</strong> auxiliary current circuits, application of line <strong>and</strong> deviceprotection switches On-delay <strong>and</strong> off-delay switching with automatic step <strong>and</strong> sequence controls40 022 <strong>Control</strong> Board IIFeatures1 circuit breaker, 3-pole, C 10 A1 circuit breaker, 1-pole, B 6 A1 signal lamp, <strong>230</strong> V, red1 signal lamp, <strong>230</strong> V, yellow1 signal lamp, <strong>230</strong> V, green1 signal lamp, <strong>230</strong> V, blue1 Emergency-Stop button1 control buttonTechnical DataMain circuit voltageMain circuit currentFrequencyBreaking capacity<strong>Control</strong> circuit voltage690 V AC max.10 A max.50/60 Hz7 kVA<strong>230</strong> V AC8


®ELABOTrainingsSystemeSet of Components40 009 S torage Board 40 210 Cont actor, control <strong>and</strong> installation circuits <strong>230</strong> V DCFeatures40 210 Cont actor, control <strong>and</strong> installation circuits2 motor protection switches 0.6...1 A with auxiliary switch3 push/lock-in switches, 1 NC /1 NO, with red pilot lamp, <strong>230</strong> V1 set of h<strong>and</strong>ling hoods for push/lock-in switches red,yellow, green1 impulse switch, 1 NO, <strong>230</strong> V coil5 main contactors, 3 kW/400 V, 1 NO, <strong>230</strong> V coil5 auxiliary contact sets, 2 NC, 2 NO1 time relay, analog, 1 NO /NC, on delay1 multifunction time relay, 1 NO/NC2 limit switches, 1 NC, 1 NO- all components equipped with 4 mm safety socket s- completely mounted on Storage BoardFunctions of the multifunction time relay- on delay- off delay- on/off delay- flasher- impulse on- impulse off- pulse shaping9


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> <strong>230</strong> V<strong>Control</strong> Board IICircuit breaker 3-pole (load circuit) <strong>and</strong>circuit breaker 1-pole (control circuit)Voltage outputsfor load circuitVoltage InputsL1, L2, L3Inputs for neutral<strong>and</strong>protective conductorRail,earthed10


®ELABOTrainingsSystemeVoltage outputsfor control circuitEmergency-Stop buttonSignal lamps<strong>230</strong> V / 6 A<strong>230</strong> V / 3 W 1 NO / 1 NCOutputfor control phaseL1Pushbutton1 NO / 1 NCmax. 250 V / 6 AOutputs for neutral<strong>and</strong> protectiveconductorOutputs forneutral conductor11


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> <strong>230</strong> V<strong>Control</strong> Board IIILearning Objectives:40 003 <strong>Control</strong> Board III Practice-oriented setting up <strong>and</strong> commissioning of contactor, control <strong>and</strong> installation circuits St<strong>and</strong>ard arrangement of main <strong>and</strong>auxiliary current circuits Systematic terminal labelling, function test <strong>and</strong> troubleshootingTechnical DataMain circuit voltageMain circuit currentFrequencyBreaking capacity<strong>Control</strong> circuit voltage690 V AC max.10 A max.50/60 Hz7 kVA<strong>230</strong> V AC40 003 <strong>Control</strong> Board III mounted12


®ELABOTrainingsSystemeExpert <strong>Circuits</strong>40 009 S torage Board 40 300 Expert Circuit sLearning Objectives: <strong>Control</strong> <strong>and</strong> installation circuits with extended protective <strong>and</strong> tripping functions <strong>Control</strong> <strong>and</strong> installation circuits with extended timer functions Configuring, setting up <strong>and</strong> commissioning control <strong>and</strong> installation circuitsFeatures40 300 Expert Circuit s1 RCD circuit breaker, 4-pole, 30 mA1 RCD circuit breaker, 2-pole, 10 mA1 overload relay, 0.45...0.63 A2 RCD auxiliary switches1 operating current trigger1 undervoltage trigger2 limit switches, 1 NC, 1 NO1 digital week timer, coil <strong>230</strong> V1 multifunction relay, coil <strong>230</strong> V4 system housings for front-mounted devices1 consumer socket1 Storage BoardFunctions of the multifunction relay- on delay- off delay- on/off delay- flasher- impulse on- impulse off- pulse shaping13


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> <strong>230</strong> VLOGO! <strong>230</strong> VLearning Objectives: Connecting logical modules <strong>and</strong> testing basic functions Generating function plans from circuit diagrams PC programming, visualizing <strong>and</strong> documenting the application40 017 PLC Board <strong>230</strong> V with LOGO! <strong>230</strong>RC V6.0FeaturesExpansionIntegrated backlit display field <strong>and</strong> operator control p anelIntegrated EEPROM memory for control program <strong>and</strong> internal setpoint values8 inputs4 relay outputs 10 A max.- 10 A (with resistive load)- 3 A (with inductive load)Short circuit protection by external fusing8 integrated time switches8 push/lock-in switches for input simulation40 019 <strong>230</strong> V relay 4DI /4DO14


®ELABOTrainingsSystemeLOGO! <strong>230</strong> V40 015 PLC Board <strong>230</strong> V40 804 User manual LOGO!40 808 Sof tware LOGO! Soft Comfort V6.0NEW40 041 Text display LOGO! TD with connecting cable 2.5 m 40 029 LOGO! PC cable USB15


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> <strong>230</strong> VSwitch Board IIILearning Objectives: Connecting h<strong>and</strong>-operated industrial low-voltage switching devices Function test of start, reversing <strong>and</strong> step circuits Troubleshooting <strong>and</strong> maintenance40 007 Switch Board IIIFeatures1 Emergency-Stop button (2 NC)4 control pushbuttons (NC, NO)2 control switches (h<strong>and</strong>, 0, automatic, 2 NO)1 signal lamp, <strong>230</strong> V AC, red1 signal lamp, <strong>230</strong> V AC, greenTechnical DataRated voltageRated current<strong>230</strong> V AC5 A16


Industrial Measuring InstrumentsIndustrial measuring instruments40 009 S torage Board 40 400 Industrial Measuring Instrument sLearning Objectives: Connecting measuring instruments for current, voltage, consumption <strong>and</strong> working hours Using current transformers for extension of measuring range / galvanic isolation Installing remote measuring points, exp<strong>and</strong>ed function with selector switchesFeatures1 ammeter, analog3 current transformers1 current selector switch1 voltmeter, digital1 voltage selector switch1 frequency meter1 three-phase current meter1 AC meter1 operating hours counterTechnical DataMeasuring RangesMain circuit voltageMain circuit currentFrequencyBreaking capacity<strong>Control</strong> circuit voltage690 V AC max.10 A max.50/60 Hz7 kVA<strong>230</strong> V ACVoltageFrequencyCurrent0 ... 600 V40 ... 80 Hz0 ... 5 A directly,0 ... 50 A viacurrent transformer17


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> 24 V<strong>Control</strong> Board IV40 004 <strong>Control</strong> Board IVLearning Objectives: Practice-oriented setting up <strong>and</strong> commissioning of contactor, control <strong>and</strong> installation circuits St<strong>and</strong>ard arrangement of main<strong>and</strong> auxiliary current circuits Systematic terminal labelling, function test <strong>and</strong> troubleshooting Setting up safety circuits of all categories with contactors St<strong>and</strong>ard arrangement of control, release <strong>and</strong> load current circuitsTechnical DataMain circuit current<strong>Control</strong> circuit current6 A max.24 V DC<strong>Control</strong> Board IV mounted with 4 cont actors18


®ELABOTrainingsSysteme


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> 24 V<strong>Control</strong> Board V40 023 <strong>Control</strong> Board VLearning Objectives: St<strong>and</strong>ard arrangement of a load circuit in a 24 V control circuit Getting familiar with line protection devices Getting familiar with motor protection devices Load circuit structure Commissioning <strong>and</strong> troubleshootingFeatures1 circuit breaker, 3-pole, C 10 A2 motor protection switches, 0.6 … 1 Awith auxiliary switchTechnical DataMain circuit voltage <strong>230</strong> - 400 V ACMain circuit current 10 A max.Frequency50/60 HzBreaking capacity 6 kVA <strong>Control</strong> Board Vwith 2 motor protection switches20


®ELABOTrainingsSystemeSwitch Board II40 000 Switch Board IILearning Objectives: Setting up <strong>and</strong> testing a control current circuit Superordinate comm<strong>and</strong> devices, control buttons, control switches <strong>and</strong> Emergency-Stop buttons Signal lampsTechnical DataRated voltageRated current24 V DC5 A40 201 <strong>Contactor</strong>, control <strong>and</strong> installation circuits2 motor protection switches 0.6...1A with auxiliary switch3 push/lock-in switches, 1 NC/1 NO,with red pilot lamp, 24V1 set of h<strong>and</strong>ling hoods for push/lock-in switches red,yellow, green1 impulse switch, 1 NO, 24 V coil5 main contactors, 3 kW/400 V, 1 NO, 24 V coil5 auxiliary contact sets, 2 NC, 2NO1 time relay, analog, 1 NO/NC, on delay1 multifunction time relay, 1 NO/NC2 limit switches, 1 NC, 1 NO- all components equipped with 4 mm safety socket s- completely mounted on Storage BoardFeatures1 Emergency-Stop button (2 NC )4 control pushbuttons (NC, NO)2 control switches (h<strong>and</strong>, 0, automatic,2 NO)1 signal lamp, 24 V DC, red1 signal lamp, 24 V DC, green40 201 <strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong><strong>Installation</strong> <strong>Circuits</strong> 24 V21


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> 24 VLOGO! 24 VLearning Objectives: Connecting logical modules <strong>and</strong> testing basic functions Gernerating function plans from circuit diagrams PC programming, visualizing <strong>and</strong> documenting the applicationFeaturesIntegrated backlit display field <strong>and</strong> operator control p anelIntegrated EEPROM memory for control program <strong>and</strong> internal setpoint values8 inputs (4 of which apt for analogue use)4 relay outputs 10 A max.- 10 A (with resistive load)- 3 A (with inductive load)Short circuit protection by external fusing8 integrated time switches8 push/lock-in switches for input simulation40 016 PLC Board 24 V with LOGO! 12/24RC V6.0Expansions63 524 24V DCPower Supply Board 2.5 A40 018 LOGO! exp ansion:12/24 relay with 4 DI/4 DO40 025 AS-i expansionmodule40 026 KNX/EIBexpansion module22


®ELABOTrainingsSystemeLOGO! 24 V40 014 PLC Board 24 VM60 007LOGO! Trainer without LOGO!with 30 process module cards <strong>and</strong> power supply p ack40 033 LOGO! T rainer with mounted traffic lightmodule <strong>and</strong> expansion 40 01840 034 Traffic light module23


<strong>Contactor</strong>, <strong>Control</strong> <strong>and</strong> <strong>Installation</strong> <strong>Circuits</strong> 24 VSafety Relays40 050 Safety Universal Relay BoardLearning Objectives: Setting up <strong>and</strong> testing safety circuits with safety relays Systematic terminal labelling, function test <strong>and</strong> troubleshooting Arrangement in main, release <strong>and</strong> auxiliary current circuits Commissioning different safety relays such as Emergency-Stop monitoring, safety doormonitoring or two-h<strong>and</strong> operation AOPD evaluation for opto-electronic safety systems40 053 Universal RelayEmergency-StopSafety door monitoring40 054 Universal RelayEmergency-StopSafety door monitoringSafe time function40 055 Relay forTwo-H<strong>and</strong> Operation24


®ELABOTrainingsSystemeSafety Position Switches40 052 Safety Position Switch BoardLearning Objectives: Setting up control circuits in the control categories 1- 4 <strong>Installation</strong> circuits with control guards Redundant setup of safety circuits <strong>Control</strong> guards with interlocking Indication of installation states by signal lampsFeatures1 safety position switch with interlocking1 safety position switch withseparate actuator - cat. 22 safety position switcheswith roll lever1 signal lamp, red 24 V DC1 signal lamp, green 24 V DCTechnical Data<strong>Control</strong> circuit voltageRated currentOperating voltageof lamps24 V DC5 A24 V DC25


Measuring <strong>and</strong> Test InstrumentsDigital multimeters90 280 Digit al multimeter90 281 True-rms digital multimeterTechnical Data90 280 Digital multimeterDC voltage 0.001 V - 600 VAC voltage 0.001 V - 600 VDC current 0.001 A - 10 AAC current 0.001 A - 10 AResistance 0.1 Ω - 40 MΩCapacitance 1 nF - 10,000 µFFrequency 0.01 Hz - 50 kHzDisplay6,000 countsAnalog bargraphwith 33 segmentsDiode testrange/resolution: 2.00 V /0.001 VTechnical Data90 281 True-rms digital multimeterDC voltage 0.1 mV - 1000 VAC voltage 0.1 mV - 1000 VDC current 0.01 mA - 10 AAC current 0.01 mA - 10 AResistance 0.1 Ω - 50 MΩCapacitance 1 nF - 10,000 µFFrequency 0.01 Hz - 100 kHzTemperature -40°C - 400°CDisplay6,000 countsAnalog baragraphwith 33 segmentsDiode testrange/resolution:2.00 V /0.001 VAudible continuitytester26


®ELABOTrainingsSystemeTechnical Data90 282 True-rms logging multimeter with PCinterface <strong>and</strong> softwareDC voltage 1 µV - 1000 VAC voltage 1 µV - 1000 VDC current 0.01 µA - 10 AAC current 0.01 µA - 10 AResistance 0.01 Ω - 500 MΩCapacitance 1 pF - 50,000 µFFrequency 0.01 Hz - 1 MHzTemperature -200.0 °C to 1350.0 °CConductance 0.01 nS - 500 nSDisplay50,000 counts 320 x 240 dot LCDLogging memory 180 hours90 282 True-rms logging multimeterAccessoriesincluded!27


CoursewareManualContents of manualIntroduction1.1 <strong>Control</strong>ling with control switch ON/OFF1.2 <strong>Control</strong>ling with direction of rot ation switch1.3 <strong>Control</strong>ling with star/delta switch1.4 <strong>Control</strong>ling with star/delta reversing switch1.5 <strong>Control</strong>ling with pole changing switch1.6 <strong>Control</strong>ling with pole changing switchfor two seperate windingsContents of transparencies setOn paper <strong>and</strong> on CD!Switch Board ICam switchesLoad disconnecting switches: definition, function<strong>and</strong> applicationLoad disconnecting switches: device structure<strong>and</strong> switch typesStar-delta switchesStar-delta reversing switchesPole-changing switches for Dahl<strong>and</strong>er circuitsPole-changing switches for seperate windings<strong>Control</strong> <strong>and</strong> indicating devicesMushroom-head buttons<strong>Control</strong> TechnologyPart 1: H<strong>and</strong>-operated switches<strong>Control</strong> TechnologyPart 1: H<strong>and</strong>-operated switches<strong>Control</strong> TechnologyPart 1: H<strong>and</strong>-operated switchesTrainer SectionPractical ExperimentsSet of TransparenciesE40 101CD Manual Trainer SectionPart 1: H<strong>and</strong>-operated SwitchesE40 100CDManualPractical ExperimentsPart 1: H<strong>and</strong>-operated SwitchesE40 102CD Set of T ransparenciesPart 1: H<strong>and</strong>-operated Switches28


®ELABOTrainingsSystemeE40 120 Set of TechnoCardsconsisting ofE40 113 Direct switching of three-phase asynchronous motorswith control switch ON/OFF (experiment 1)E40 114 Direct switching of three-phase asynchronous motorswith direction of rotation switch (experiment 2)E40 115 Starting three-phase asynchronous motorswith a star-delta switch (experiment 3)E40 116 Starting three-phase asynchronous motors witha star-delta reversing switch (experiment 4)E40 117 Starting three-phase asynchronous motors withspeeds via a pole-changing switch (experiment 5)E40 118 <strong>Control</strong>ling three-phase asynchronous motorswith seperate windingsvia pole-changing switch (experiment 6)E40 119 Switch Board ITransparencies Sets<strong>Control</strong> TechnologyPart 3: Expert <strong>Circuits</strong><strong>Control</strong> TechnologyPart 4: Industrial Measuring InstrumentsSet of TransparenciesSet of TransparenciesE40 301CD Set of TransparenciesPart 3: Expert <strong>Circuits</strong>E40 401CD Set of TransparenciesPart 4: Industrial Measuring Instruments29


CoursewareManualContents of manualOn paper <strong>and</strong> on CD!<strong>Control</strong> TechnologyPart 2: <strong>Contactor</strong> <strong>Circuits</strong>Trainer Section1. Task2. Circuit diagram3. Equipment list4. Function description5. Additional task6. QuestionExperiment 1:Direct switching of three-phaseasynchronous motorsExperiment 2:Delayed switching of three-phaseasynchronous motorsExperiment 3:Switching of three-phase asynchronous motorsfor optional feed-infrom two different power suppliesExperiment 4:Changing of the direction of rot ationof a three-phase asynchronous motor(reversing control)Experiment 5:Changing of the direction of rot ationof a three-phase asynchronous motor(reversing control) with limit switchExperiment 6:Starting of a three-phase asynchronous motorwith a h<strong>and</strong>-operatedstar-delta contactor sequence circuitExperiment 7:Starting of a three-phase asynchronous motorwith an automaticstar/delta contactor sequence circuitExperiment 8:<strong>Control</strong>ling of a three-phase asynchronous motorwith current impulse relay - impulse controlON/OFFExperiment 9:Starting of a three-phase asynchronous motorwith a h<strong>and</strong>-operated star-delta contactorsequence circuit for two directions of rot ationExperiment 10:Starting of a two-speed three-phase asynchronous motor with a contactor controlledpole changing circuit - Dahl<strong>and</strong>er circuitE40 202CDManual T rainer SectionPart 2: <strong>Contactor</strong> <strong>Circuits</strong>30


®ELABOTrainingsSysteme<strong>Control</strong> TechnologyPart 2: <strong>Contactor</strong> <strong>Circuits</strong><strong>Control</strong> TechnologyPart 2: <strong>Contactor</strong> <strong>Circuits</strong>Practical ExperimentsSet of TransparenciesE40 201CDManualPractical ExperimentsPart 2: <strong>Contactor</strong> <strong>Circuits</strong>E40 203CDSet of T ransparenciesPart 2: <strong>Contactor</strong> <strong>Circuits</strong>E40 242 Set of TechnoCardsconsisting ofE40 233 ref. to experiment 1E40 234 ref. to experiment 2E40 235 ref. to experiment 3E40 236 ref. to experiment 4E40 237 ref. to experiment 5E40 238 ref. to experiment 6E40 239 ref. to experiment 7E40 240 <strong>Control</strong> Board IIE40 241 ref. to experiment 8E40 243 ref. to experiment 9E40 244 ref. to experiment 1031


CoursewareManualContents of manual1. Main switch - switches - consumers2. Hall lighting with surge relay3. Stairway lighting with automatic control4. Setting the time <strong>and</strong> clock operation5. Stairway lighting:linking with the PCOn paper <strong>and</strong> on CD!Trainer SectionPractical ExperimentsE40 801CDManual T rainer SectionLOGO!E40 802CDManual Practical Experiment sLOGO!32


®ELABOTrainingsSystemeE40 803CDSet of TransparenciesSet of T ransparencies LOGO!Contents of transparencies setLOGO!Areas of application <strong>and</strong> advantages of LOGO!Connections, input - outputconnect LOGO!Important termsAbbreviations usedBasic functions (BF)Special functions (SF)Conversion circuit diagram - LOGO! programInput <strong>and</strong> output boxesProgramming rulesProgramming menusProgram <strong>and</strong> wiringEntering the programParameterizing LOGO!The integrated clockLink LOGO! - PCThe software LOGO! Soft ComfortProgram editing with LOGO! Soft ComfortSurvey circuit <strong>and</strong> comments in LOGO! Soft ComfortLOGO! with AS interfaceE40 813TechnoCardPLC Board 24V DC with LOGO!E40 814TechnoCardPLC Board <strong>230</strong>V AC with LOGO!LOGO! is a registered trademark of Siemens AG33


CoursewareManualContents of manualOn paper <strong>and</strong> on CD!Introduction:"Safety technology for protection of man <strong>and</strong>machine; applicable st<strong>and</strong>arts <strong>and</strong> directives;four-point measure catalogue; risk assessment;risk evaluation; implementation of st<strong>and</strong>arts <strong>and</strong>directives; functions for safety achievement;general principles for the design of interlockingdevices; Emergency-stop requirements fordevices; stop category"<strong>Circuits</strong> for the followingcontrol categories:<strong>Control</strong> category 1<strong>Control</strong> category 2<strong>Control</strong> category 3<strong>Control</strong> category 4<strong>Control</strong> category 2 with interlocking<strong>Control</strong> category 4 with interlockingSafety Technology:<strong>Contactor</strong> <strong>Circuits</strong>Safety Technology:<strong>Contactor</strong> <strong>Circuits</strong>Safety Technology:<strong>Contactor</strong> <strong>Circuits</strong>Trainer Section Practical Experiments Set of TransparenciesE40 500CD Manual Trainer SectionSafety Technology: <strong>Contactor</strong> <strong>Circuits</strong>E40 501CDManualPractical ExperimentsSafety Technology: <strong>Contactor</strong> <strong>Circuits</strong>E40 502CD Set of T ransparenciesSafety Technology: <strong>Contactor</strong> <strong>Circuits</strong>34


®ELABOTrainingsSystemeContents of transparencies setE40 503CDSafety Technology:General InformationSet of TransparenciesSet of T ransparenciesGeneral InformationSafety of machines: What for?Applicable st<strong>and</strong>artsMachine DirectiveTerm „Machine“Types of st<strong>and</strong>artsFrom where do dangers originate?How can hazards be prevented?Planning phaseDesign of a machineProcess for achieving the safetyRisk assessment / Risk analysisRisk estimation EN 954-1/ EN1050Evaluation softwareThe risk assessmentProcess for achieving the safetyRisk minimisationResidual risk?Category BCategory 1 / Category 2 / Category 3 / Category 4Safety relayEmergency-Stop circuitThe EN 418The STOP categoriesOpto-electronic protective deviceFail-safe bus system AS-iExamplesE40 570 Set of TechnoCardsconsisting ofE40 571 TechnoCard: Emergency shutdown (SC 1)E40 572 TechnoCard: Emergency shutdown (SC 2)E40 573 TechnoCard: Emergency shutdownwhen safety door is opened (SC 3)E40 574 TechnoCard: Protective circuitwith Emergency-Stop monitoringE40 575 TechnoCard: Emergency-Stopin the control current circuit whensafety door is opened (SC 4)E40 576 TechnoCard: <strong>Control</strong> category 2with interlockingE40 577 TechnoCard: <strong>Control</strong> category 4with interlocking35


®ELABOTrainingsSystemeContents of transparencies setSafety Technology:<strong>Circuits</strong> withSafety RelaysSet of TransparenciesE40 512CDSet of T ransparenciesSafety Technology: <strong>Circuits</strong> with Safety RelaysSafety relay “Emergency-Stop <strong>and</strong> safety door monitoring"Safety relay "two-h<strong>and</strong> operating element"Safety relay "safe time function"LegendPrinciplesApplicationsSchematic diagram of a safety relaySafe isolationPositively driven operationSafety relay for Emergency-Stop monitoringSafety relay for two-h<strong>and</strong> operationSafety relay with time functionExperiments with safety relay for Emergency-Stop<strong>and</strong> safety door monitoring:Emergency-Stop monitoring - control category 2Emergency-Stop monitoring - control category 4Emergency-Stop monitoring - control category 4,with reset buttonSafety door monitoring - control category 4Experiments with two-h<strong>and</strong> operating element:Two-h<strong>and</strong> operationSafety door monitoring - control category 4Experiments with safety relay “safe time function”:Safety interlocking - control category 2Safe time function with reset switchSafety door opening after definite timeSafety door opening after definite time with reset buttonE40 513TechnocardSafety relay forEmergency-Stop <strong>and</strong>safety door monitoring37


Information <strong>and</strong> adviceWe offer: Selection of products complying with syllabuses Comprehensive system determination Service-Center - we will call you back <strong>and</strong>support you in planning <strong>and</strong> projectdevelopment Classroom layout concepts Ergonomic workplace design Joint compilation of offers Information about our products / manuals Planning of seminarsWe will help you ... in all questions concerning the equipmentfor vocational technical education on site over the telephoneContact:ELABOTrainingsSysteme GmbHService-CenterIm Huettental 1185125 Kinding / GermanyTel.: +49/ (0)8467/ 84 04 - 0Fax: +49/ (0)8467/ 84 04 44sales@elabo-ts.comhttp://www.elabo-ts.comWhere this catalogue ends,we start consulting ....Experience: Comprehensive range of innovative products,systems <strong>and</strong> solutions Quality service from first consultation todelivery <strong>and</strong> beyond Trainer-seminars / Inhouse-trainingsProjects <strong>and</strong> references: Industrial training institution Vocational schools / technical colleges Chambers of commerce Academies / Universities38


Your enquiryELABOTrainingsSysteme®ELABOTrainingsSystemeAus- und Weiterbildung GmbHIm Huettental 1185125 Kinding − GermanyTel.: +49/ (0) 84 67/ 84 04 - 0FAX: +49/(0) 84 67/ 84 04 44Name, Occupation / PositionCompany / Institution / Authority / SchoolStreet, PO BoxPostcode, Town /City, CountryTelephone Telefax E-mailPlease send usthe followingThe solutioncatalogue(s):System <strong>and</strong>Process SimulationSafety of Electric<strong>Installation</strong>s <strong>and</strong> DevicesTrainer PackagesSystem <strong>and</strong>Process SimulationSafety of Electric<strong>Installation</strong>s <strong>and</strong> DevicesTrainer PackagesThe solutionPractical Trainingin Sensor TechnologyElectrical Engineering /Electronics / Digital TechnologyHome <strong>and</strong> Building <strong>Control</strong>KNX / EIBOperator <strong>Control</strong> <strong>and</strong> MonitoringHuman Machine InterfacePractical Trainingin Sensor TechnologyElectronic Engineering /Electronics / Digital TechnologyHome <strong>and</strong> Building <strong>Control</strong>KNX / EIBOperator <strong>Control</strong> <strong>and</strong>MonitoringElectronicsLaboratorySystemsCommunication SystemsISDN <strong>and</strong> analogMicrocontrollerTechnologyCopy <strong>and</strong> faxCommunication SystemsISDN <strong>and</strong> analogMicrocontrollerTechnologyElabo ElectonicsElaboLaboratory SystemsSubject to technical modifications <strong>and</strong> further development s01/200939


®ELABOTrainingsSystemeAus- und Weiterbildung GmbHELABOTrainingsSysteme GmbHIm Huettental 1185125 Kinding / GermanyTel.: +49 / (0)8467/ 84 04 - 0Fax: +49/ (0)8467/ 84 04 44E-mail: sales@elabo-ts.comInternet: http://www.elabo-ts.com