TestersHI 98121pH/ORP Waterproof Tester• HANNA’s exclusive cartridge pH and ORP electrodeElectrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement.• Renewable cloth pH junctionWhen the cloth junction becomes dirty from routine testing, simply pull out 3 mm (1/8”) to rejuvenate the electrode.• Dual-level LCD• Automatic temperature compensation• Automatic calibration• Automatic shut-off• “Direct Contact” temperature probeIt Floats!The HI 98121 new waterproof combo measures pH, ORP, and temperature—Great for testing the efficiency ofozone injectors.SPECIFICATIONS HI 98121Range pH: -2.00 to 16.00; ORP: ±1000 mV; Temp.: -5.0 to 60.0°C or 23.0ResolutionpH: 0.01; ORP: 1 mV; Temperature: 0.1°C or 0.1°FAccuracy (@20°C/68°F)pH: ±0.05; ORP: ±2 mV; Temperature: ±0.5°C or ±1°FCalibrationpH: 1 or 2 points with 2 sets of memorized buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18);ORP: Factory calibratedTemp. CompensationAutomatic for pHBattery Type(4) 1.5V with BEPS (Battery Error Prevention System)Battery LifeApprox. 250 hours of continuous use; auto shut-off after 8 minutes of non-useEnvironment-5 to 50°C (23 to 122°F); 100% RHDimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1”)Weight85 g (3.0 oz.)Replaceable pHelectrode cartridgeORDERING INFORMATIONHI 98121 is supplied with protective cap, electrode removaltool, batteries and instructions.ACCESSORIESHI 73127 pH electrode (HI 98121)HI 73120 ORP electrode (HI 98120)HI 7004M pH 4.01 buffer solution, 230 mLHI 7007M pH 7.01 buffer solution, 230 mLHI 7010M pH 10.01 buffer solution, 230 mLHI 7020M 200/275 mV test solution, 230 mL bottleHI 7091M Reducing solution, 230 mL bottleHI 7092M Oxidizing solution, 230 mL bottleHI 70300M Storage solution, 230 mLHI 7061M Cleaning solution, 230 mLHI 98204Water Test pH/ORP/EC/Temperature Portable Unit• Lightweight• Quick and reliable• Easy to useThe perfect tool for checking water quality when you’refar from the lab, whether you’re in the middle of acresof ponds or on a catwalk over a tank.SPECIFICATIONSHI 98204 (Water Test)RangepH: 0.0 to 14.0; ORP: ±1000 mV; EC: 0 a 1999 μS/cm; Temp.: 0.0 to 60.0°CResolutionpH: 0.1; ORP: 1 mV; EC: 1 μS/cm; Temp.:0.1°CAccuracy (@20°C/68°F)±0.2 pH ±5 mV ±2% F.S. ±1°CCalibrationpH: Manual, 2 points; ORP: factory calibrated; EC: manual, 1 point;Temp.:factory calibratedBattery Type / Life(3) 1.5V / approx. 200 hours of continuous useEnvironment 0 to 50°C (32 to 122°F); RH max 95%Dimensions 190 x 85 x 85 mm (7.5 x 3.3 x 3.3’’)Weight260 g (9.2 oz.)ORDERING INFORMATIONHI 98204 (Water Test) is supplied with measuring compartment,batteries and instructionsACCESSORIESHI 740088 Plastic vessel for sampleHI 7004M pH 4.01 buffer sol., 230 mLHI 7007M pH 7.01 buffer sol., 230 mLHI 7010M pH 10.01 buffer sol., 230 mLHI 7020M 200/275 mV test sol., 230 mLHI 7091M Reducing solution, 230 mLHI 7092M Oxidizing solution, 230 mLHI 7031M 1413 μS/cm calibration solution, 230 mLHI 70300M Storage solution, 230 mL(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com7


Portable MetersPortableMetersThe hand held meter is a sophisticatedinstrument and incorporates many usefulfeatures not found in a pocket tester. Handheldinstruments are also more durable andhave a longer useful life than pocket testers.If your major concern is cost and good basicperformance, then the pocket tester may bethe right fit for your needs. If increased accuracy,durability and additional features areimportant in your measurements, then ahand held instrument is a better choice inthe long run. The following are our rugged,waterproof pH meters, with various featuresto meet every need.p HpH has an incredible impact on the healthof aquatic plants and animals. As pHincreases, so does the percentage ofammonia in its more toxic unionized form.Ammonia excretion is also impaired athigher pH, limiting an organism’s ability topurge itself of its waste product. KeepingpH stable and in optimal range reducesstress on your fish and aquatic animals,helping them resist disease and tolerateother stressors. Maintaining an ideal pHcan dramatically improve growth, behaviorand overall appearance.ORPORP stands for Oxidation-ReductionPotential. It is also sometimes known asthe Redox Potential. Very simply put, it isthe ability of the water to cleanse itself bybreaking down contaminants. For example,if one put a piece of iron in a swimmingpool, it would rust. This is a form of oxidation:the oxygen from the water and the chlorinereacts with the iron, causing it to breakdown into rust. The same process occurswhen an oxidizing agent like chlorine orozone comes in contact with bacteria andother microbes; instead of rusting, they aredestroyed or decomposed.8HI 98180 • HI 98181Graphic LCD pH MetersHANNA instruments ®• Calibration Check: pH electrode condition, clean electrode/contaminated buffer warning, outside calibration range warning• 0.001 pH resolution• Stainless steel pH electrode with built-in temperature sensor• Up to 3 calibration points with standard or custom buffers• Relative mV scaleThese instruments have many innovative features, including: rechargeable batteries (alkalinebatteries can also be used), inductive recharging (with a 115v standard outlet or a 12V caradapter), our exclusive Calibration Check (electrode status), a 128 X 64 pixel graphic LCD, andcomprehensive Good Laboratory Practices (GLP). Waterproof casing is available.Backlit graphic LCD and battery life on displayRugged, durable casingUSBUNIVERSAL SERIAL BUS


Portable MetersMeasurement ScreenElectrode condition and calibrationpoints shown.pH CalibrationDetailed Calibration Check messages.SPECIFICATIONS HI 98180 HI 98181RangepH: -2.0 to 16.0; -2.00 to 16.00;Temp: -20.0 to 120.0 °C (-4.0 to 248.0°F)pH: -2.0 to 16.0; -2.00 to 16.00; mV: ±2000;Temp: -20.0 to 120.0 °C (-4.0 to 248.0°F)Resolution pH: 0.1; 0.01; Temp:0.1°C (0.1°F) pH: 0.1; 0.01; mV: 0.1; Temp:0.1°C (0.1°F)AccuracypH CalibrationpH: ±0.01; Temp: ±0.4°C (±0.8°F)(excluding probe error)Up to 2 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)pH: ±0.01; mV: ±0.2 mV; Temp: ±0.4°C (±0.8°F)(excluding probe error)Up to 3 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)Slope Calibration From 80 to 110%Temp. CompensationManual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)ProbesHI 1230B pH electrode w/BNC and HI 7662 temperatureLoggingSingle readingPC Connectivity —Input Impedance10 12 OhmsBattery Type/Life(4) 1.2V AA rechargeable batteries/approx. 200 hrs continuous use (without backlight)RechargerInductive recharger (included)Auto-offUser Selectable: 5, 10, 30, 60 min or can be disabledEnvironment 0 to 50°C (32 to 122°F); RH 95%Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)Weight525 gORDERING INFORMATIONHI 98180 and HI 98181 are supplied with HI 1230B pH electrode, HI 7662 temperature probe, pH 4.01 and pH 7.01 buffersolutions; (4) 1.2V AA, 1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with power adapter; rugged carryingcase and instructions.Rechargeable batteries with inductive rechargerThese models have up to 200 hour extended battery life to guarantee long operationin the field. When the batteries are low, you don’t have to worry about carrying a spareset with you—the batteries can be recharged with HANNA’s inductive recharger.Simply leave the meter on the recharger for a few hours and you’re ready to go. Therecharger can either be plugged in a standard 115V socket using the includedHANNA adapter or a 12 VDC source such as a car's 12 volt accessory outlet.MeasurementLarge backlit graphic display showsmultiple messages along with thecurrent measurement readings.Language SelectionHelp screens and guides are availablein a choice of languages.HelpUsers can consult the on-screen helpfrom any mode simply by pressingthe HELP key. The instrument will thenexplain the function and optionscurrently available.GLPComprehensive GLP functions aredirectly accessible by pressing theGLP key.TankTipThe pH requirements offresh water fish canvary greatly by species.Certain African cichlidswhich prefer hard waterthrive at a pH of 8.0, whilesoft-water loving fish likediscus need a pH of 6.5,and cold-water tropicalfish like goldfish like pH7.4 water best.Chemical test kits usingcolor charts have a resolutionof only 0.5, while aHANNA pH meter can berelied upon to provideincredibly precise andaccurate readings of upto 0.01 pH!(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com9


Portable MetersHI 9026pH/ORP Meter with Calibration Check• Backlit, dual-level LCD• Measures in °C or °F• 7 memorized buffers for calibration• Custom calibration with two custom buffers• Display hold and memory storage• User-selectable calibration reminderThis advanced pH/ORP meter has a large, backlit LCD for clear readings in dark environments.SPECIFICATIONS HI 9026RangepH: -2.00 to 16.00; mV: ±699.9 to ±1999; Temp.: -20.0 to 120.0°C/-4.0 to 2482.0°FResolutionpH: 0.01; mV: 0.1, 1; Temperature: 0.1°C/0.1°FAccuracy (@20°C/68°F)pH: ±0.01; mV ±0.2, ±1; Temperature: ±0.4°C/±0.8°FCalibration CheckCheck of the electrode status during calibrationpH CalibrationAutomatic, 1 or 2 point with 7 memorized buffer values (pH 1.68, 4.01, 6.86, 7.01,9.18, 10.01, 12.45); + 2 custom buffersTemp CompAutomatic or manual, -20 to 120°C (-4°F to 248°F)pH ElectrodeHI 1230B, double junction, PEI body, gel filled, BNC conn. and 1 m cable (included)Temperature ProbeHI 7669 with 1 m (3.3’) cable (included)Input Impedance10 12 OhmBattery Type/Life(4) 1.5V AA / approx. 500 hours of continuous use (without backlight);auto-off after 20 minutes of non-use (can be disabled)Environment0 to 50°C (32 to 122°F); 100% RHDimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’)Weight500 g (1.1 lb.)ORDERING INFORMATIONHI 9026 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, pH 4 and pH 7 buffer sachets,100 mL plastic beaker, batteries, rugged carrying case and instructions.TankTipACCESSORIESHI 3230B ORP electrode, gel filled, PEI body, BNCconnector, 1 m cableHI 7007L pH 7.01 buffer solution, 500 mLHI 7010L pH 10.01 buffer solution, 500 mLHI 70300L Electrode storage solution, 500 mLHI 7061L Electrode cleaning solution, 500 mLORP is the best way to measurewater’s potential ability to oxidizeorganic contaminants. Inother words, ORP can be usedas an indicator of water quality.Many consider an ORP level of250-400 mV to be reflective ofgood to optimal water quality;this level can be maintained byusing aeration, ozone, or a UVsterilizer. ORP levels below 200mV can indicate low dissolvedoxygen, high nitrites, or highDOC (Dissolved OrganicCarbon). DOC promotes theincrease of harmful bacteria.However, ORP levels exceeding550 mV are harmful to animalsand plants. Levels this highshould only be used as a sterilizingagent to treat water thatcontains no live stock.HI 9026 Calibration Check SystemClean ElectrodeEach time pH calibration isperformed, the meter internallycompares the newcalibration with the onepreviously stored. When this comparisonindicates a significant difference, the cleanmessage blinks on the LCD to advise the userthat the pH electrode may need to be cleanedand another calibration will need to be performed.81 to 100% LifeExpired CalibrationThe instrument is providedwith a real time clock (RTC)in order to monitor the timeelapsed since the last pHcalibration. The RTC is reset every time the meterdetects a calibration time-out. The CAL tag willstart blinking to warn the user that the meter shouldbe calibrated.Electrode ConditionThe HI 9026 display features a bar graph which displays the status of theelectrode after calibration. The bargraph remains active for 12 hours aftercalibration, then only the frame is shown on the display.61 to 80% Life 41 to 60% Life 21 to 40% Life 1 to 20% Life 0% Life(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com11


Portable MetersHI 9024 • HI 9025pH and pH/ORP Meterswith Temperature• <strong>Special</strong>ized electrode• High accuracy• Fast response• Automatic temperaturecompensationConductivityConductivity (EC) is a measure of the ability ofwater to pass an electrical current.Conductivity in water is affected by the presenceof inorganic dissolved solids such aschloride, nitrate, sulfate, and phosphateanions (ions that carry a negative charge) orsodium, magnesium, calcium, iron, and aluminumcations (ions that carry a positivecharge). These are called Total DissolvedSolids (TDS). Conductivity is also affected bytemperature: the warmer the water, the higherthe conductivity. For this reason, conductivityis reported as conductivity at 25 degreesCelsius (25 °C). Our waterproof conductivityand total dissolved solids meters have manyapplications, such as:This family of pH meters feature manual or automatic temperature compensation with separatepH and temperature probes. The Auto-Instruction feature guides the user through the calibrationprocess, using one or two of five memorized buffers. The HI 9025 has the capability to measureORP as well with the optional ORP probe (HI 3230B).SPECIFICATIONS HI 9024 HI 9025RangeResolutionAccuracy (@20°C/68°F)ORDERING INFORMATIONpH: 0.00 to 14.00;Temperature: 0.0 to 100.0°C/32.0to 212.0°FpH: 0.01; Temperature: 0.1°C/0.1°FpH: ±0.01; Temperature:±0.4°C/±0.8°FHI 9024 is supplied with HI 1230B pH electrode, HI 7669/2Wtemperature probe, pH 4 and pH 7 buffer sachets, 100 mLplastic beaker, batteries, rugged carrying case and instructions.HI 9025 is supplied with HI 1230B pH electrode, HI 7669/2Wtemperature probe, pH 4 and pH 7 buffer sachets, 100 mLplastic beaker, batteries, rugged carrying case and instructions.pH: 0.00 to 14.00; mV: ±399.9 to ±1999;Temperature: 0.0 to 100.0°C/32.0to 212.0°FpH: 0.01; mV: 0.1, 1;Temperature: 0.1°C/0.1°FpH: ±0.01; mV: ±0.2, ±1;Temperature: ±0.4°C/±0.8°FpH CalibrationAutomatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18,10.01); offset calibration: ±1 pH; slope calibration: 70 to 108%Temp. CompensationAutomatic or manual, -5 to 105°C (23°F to 221°F)pH ElectrodeHI 1230B, double junction, PEI body, gel filled, BNC connectorand 1 m cable (included)Temperature ProbeHI 7669/2W with 1 m (3.3’) cable (included)Input Impedance10 12 OhmBattery Type/Life(4) 1.5V AA / approx. 500 hours of continuous use;auto-off after 20 minutes of non-use(can be disabled)Environment0 to 50°C (32 to 122°F); 100% RHDimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’)Weight500 g (1.1 lb.)ACCESSORIESHI 3230B ORP electrode, gel filled, PEIbody, BNC, 1 m cableHI 7007L pH 7.01 buffer solution,500 mL bottleHI 7010L pH 10.01 buffer solution,500 mL bottleHI 70300L Electrode storage solution,500 mL bottleHI 7061L Electrode cleaning solution,500 mL bottleHI 8427 pH/mV electrode simulator- Monitor TDS levels for sensitive speciessuch as discus.- Use in conjunction with R/O units, both todetermine membrane efficiency (outflow ofwater should read 5-25 uS/cm) and correctapplication of the purified water.- Take precise salinity readings. TDS or ECcan be converted to salinity more accuratelythan a hydrometer or refractometer.Conductivity(mS/cm)(25°C)TankTipRefractiveIndex(20°C)SpecificGravity(25°C)PSU is an acronym for practical salinity units,which is essentially a modern replacementfor ppt, since salinity is no longer defined asdirectly relating to solids in the water, butrather by its conductivity.PSU0 1.333 1 046.2 1.3385 1.0226 3047.6 1.3386 1.0233 3149 1.3388 1.0241 3250.4 1.339 1.0249 33Water ConductivityPure water0.055 μS/cmDistilled water0.5 μS/cmMountain water1.0 μS/cmDomestic water500-800 μS/cmMax. for potable water 10,055 μS/cm (10 mS/cm)Sea water52,000 μS/cm (52 mS/cm)12HANNA instruments ®


Portable MetersHI 98188EC Meter with USP• Autorange from 0.001 uS/cm to 400 mS/cm• Resistivity up to 100 Mohm•cm• Three salinity scales• 2 or 4-ring probe with auto recognition• USP stages 1, 2 and 3• Memorize up to 10 user profiles• Up to 5 calibration points• Linear and natural water temp. compensation• Interval LoggingUSBUNIVERSAL SERIAL BUSHI 98188 conductivity meter has an extended range from 0.001 μS/cmto 400 mS/cm, as well as resistivity and 3 salinity scales. This meter alsoautomatically recognizes the probe type (2 or 4-ring and nominal cell constant).Both linear and natural water temperature compensation is available and thereference temperature is user adjustable. Ten sets of measurement parameters(such as reference temperature, temperature compensation mode,TDS factor, calibration etc.) can be stored as a user profile for later use.Rechargeable batterieswith inductive rechargerThis model has up to 200 hour extendedbattery life to guarantee long operationin the field. When the batteries are low,you don’t have to worry about carrying aspare set with you—the batteries can berecharged with HANNA’s inductiverecharger. Simply leave the meter on therecharger for a few hours and you’reready to go. The recharger can either beplugged in a standard 115V socketusing the included HANNA adapter or a12 VDC source such as a car's 12 voltaccessory outlet.3 Stage ConformityThis meter can perform all 3 stages ofUSP water quality testingrequirements.On-screen GuideUsers are provided with on-screeninstructions for each USP stage.Progress BarMeter displays progress towardsmeeting stage 2 stability requirements.User Profiles10 sets of measurement parameters canbe stored in user profiles for later retrieval.SPECIFICATIONS HI 981880 to 400mS/cm (actual conductivity 1000 mS/cm)Range0.001 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm;EC1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (autoranging)Resolution0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cmAccuracy±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)Range1 to 999.9 Ohm•cm; 1.000 to 9.999 kOhm•cm; 10.00 to 99.99 kOhm•cm;100.0 to 999.9 kOhm•cm; 1.0 to 100.0 MOhm•cm (autoranging)ResistivityResolution0.1 Ohm•cm; 0.001 kOhm•cm; 0.01 kOhm•cm; 0.1 kOhm•cm; 0.1 MOhm•cmAccuracy±2% of reading (±1 Ohm•cm or 1 digit, whichever is greater)Range0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L;100.0 to 400.0 g/L (autoranging)TDSResolution0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/LAccuracy±1% of reading (±0.05 ppm or 1 digit, whichever is greater)Range %: 0.0 to 400.0%; seawater scale: 0.00 to 80.00 (PSU); Practical salinity: 0.01 to 42.00NaClResolution 0.1%; 0.01Accuracy±1% of readingRange-20.0 to 120.0°CTemperature Resolution0.1°CAccuracy±0.2°C (excluding probe error)Automatic up to 5 points with 7 memorized standards (0.00 μS/cm, 84.0 μS/cm,EC1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)CalibrationNaCl1 point only in % range (with HI 7037 buffer); Use conductivity calibration for all other rangesTemperature1 or 2 pointsTemperature Compensation-20.0 to 120.0°CReference Temperature 15°C, 20°C and 25°CTDS Factor 0.40 to 1.00ProbeHI 76310 4-ring EC probe with built-in temperature sensorLoggingLog-on-demand400 samplesInterval5 seconds to 1 minutePC ConnectivityOpto-isolated USB (with HI 92000 software)Battery Type/Life(4) 1.2V AA rechargeable batteries/approx. 100 hrs continuous use (without backlight)RechargerInductive recharger (included)Auto-offUser Selectable: 5, 10, 30, 60 min or can be disabledEnvironmentIP67Dimensions/Weight226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)/525 gORDERING INFORMATIONHI 98188 is supplied with HI 76310 4-ring conductivity probe with built-in temperature sensor, calibration solution; (4) 1.2V AA,1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with power adapter; rugged carrying case and instructions.(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com13


Portable MetersHI 9835 • HI 98360EC/TDS/NaCl/°C Meters• Auto endpoint feature (HI 98360)• HOLD feature to freeze LCD display readings (HI 98360)• PC compatible (HI 98360)• 4-ring probe enhanced with platinum for greatermeasurement stability• Automatic calibration• Automatic temperature compensation• Measure EC/TDS, NaCl and temperature with just one probe!Salinity is critical when raising eggs and fry, and measuring has never been so easy or so accurate.HI 9835 is an EC/TDS/temperature/NaCl meter with ATC and user adjustable temperaturecoefficients and TDS conversion factor for greater consistency. Multiple ranges extend from0.00 – 29.99 μS/cm (EC) all the way up to 400g/L (TDS) or 400% (NaCl), making it the perfectfor any use. Waterproof, durable, and versatile, this meter provides consistent and reproducibleresults under any working condition.HI 98360 has all the features of the HI 9835 (EC/TDS/NaCl/temperature with ATC) but has beenupgraded to include the Auto Endpoint feature and an RS 232 serial port. This meter provides theuser a way to closely monitor salinity and temperature, then download to a PC for analysis.SPECIFICATIONS HI 9835 HI 98360RangeResolutionAccuracyCalibrationTemp. CompensationTemp. CoefficientECTDS0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (actual EC)*0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (actual TDS)*NaCl 0.0 to 400.0%Temperature 0.0 to 60.0°C 9.9 to 120.0°C**ECTDS0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm0.01 ppm (mg/L), 0.1 ppm (mg/L), 1 ppm (mg/L), 0.01 g/L, 0.1 g/LNaCl 0.1%TemperatureEC ±1% (0.05 μS/cm or 1 digit) ±0.5% of readingTDS ±1% (0.03 ppm or 1 digit) ±0.5% of readingNaCl ±1% ±0.5% of readingTemperature0.1°C±0.4°CEC: Automatic, 1 point with 6 memorized values (84, 1413, 5000, 12880 and 11180 μS/cm); NaCl 1 point,with HI 7037 calibration solution (not included); Temperature: 2 point at 0 and 50°C (32 to 122°F)Automatic or manual, 0 to 60°C (32 to 140°F) (can be disabled to measure actual EC and TDS)Adjustable from 0.00 to 6.00%/°C (EC and TDS only)TDS Conversion Factor Adjustable from 0.40 to 0.80Data LoggingUp to 250 samples4-ring Probe HI 76309 with 1 m (3.3’) cable (included) HI 76309/1.5 with 1.5 m (4.9’) cable (included)Power SupplyEnvironmentDimensionsWeight* with temperature compensation function disabled ** using the proper probe(4) 1.5V AA batteries (included), approx. 200 hours of continuous use, or 12 Vdc input; auto-off after 5 minutes of non-use (can be disabled)0 to 50°C (32 to 122°F); 100% RH196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')500 g (1.1 lb.)ORDERING INFORMATIONHI 9835 is supplied with HI 76309 probe with stainless steel sensor and 1 m (3.3’) cable, batteries, rugged carrying case and instructions.HI 98360 is supplied with HI 76309/1.5 probe with 1.5 m (4.9’) cable, batteries, rugged carrying case and instructions.ACCESSORIESHI 7030L 12880 μS/cm calibration solution, 500 mLHI 7031L 1413 μS/cm calibration solution, 500 mLHI 7032L 1382 ppm calibration solution, 500 mLHI 7033L 84 μS/cm calibration solution, 500 mL bottleHI 7034L 80000 μS/cm calibration solution, 500 mLHI 7035L 111800 μS/cm calibration solution, 500 mLHI 7039L 5000 μS/cm calibration solution, 500 mLHI 7037L 100% NaCl standard solution, 500 mLHI 710005 115 Vac/12 Vdc power adapterHI 92000 Windows ® compatible application softwareHI 920011 Interface for PC connection14 HANNA instruments ®


Portable MetersHI 9033 • HI 9044Multirange EC & TDS Meters• Designed for harsh environments• Automatic temperature compensation• 4-ring probeThese conductivity meters are equipped with multiple ranges, ATC and lowbattery reading for exceptional accuracy. Great for field work, these meterscan withstand extended use in wet, humid, dusty, or muddy conditions whilestill providing accurate and reliable readings.SPECIFICATIONS HI 9033 HI 9034RangeResolution0.0 to 199.9 μS/cm;0 to 1999 μS/cm;0.00 to 19.99 mS/cm;0.0 to 199.9 mS/cm0.1 μS/cm; 1 μS/cm; 0.01mS/cm; 0.1 mS/cm0.0 to 199.9 mg/L;0 to 1999 mg/L;0.00 to 19.99 g/L0.1 mg/L; 1 mg/L; 0.01 g/LAccuracy (@20°C/68°F)±1% F.S. (excluding probe error)CalibrationManual, 1 pointTemp. Compensation Automatic, 10 to 50°C (50 to 122°F) with ß = 2%/°CProbeHI 76302W with internal temp. sensor and 1 m (3.3’) cable (incl.)Battery Type/Life(1) 9V/approx. 100 hours of continuous useEnvironment 0 to 50°C (32 to 122°F); RH max 100%Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’)Weight425 g (0.9 lb.)HI 97500Lux Meter for Rapid LightMeasurements in a Waterproof Case• Three measurement ranges• Light sensor attached to 1.5 meter coaxial cable• Rugged, waterproof case• Low-battery indicatorThis inexpensive yet accurate and dependable lux meter is a must have ifyou’re growing coral, plants, or algae. Handheld, waterproof, with four userselectable ranges up to 199.9 KLux. These photosynthetic organismsgenerally require at least 6,000 lux to thrive, so knowing when to replace yourbulbs is imperative.ORDERING INFORMATIONHI 9033 is supplied with HI 76302Wprobe with internal temperature sensor and1 m (3.3’) cable, calibration screwdriver, battery,rugged carrying case and instructions.HI 9034 is supplied complete withHI 76302W probe with internaltemperature sensor and 1 m (3.3’) cable,calibration screwdriver, battery, ruggedcarrying case and instructions.ACCESSORIESHI 7030L 12880 μS/cmcalibration solution, 500 mLHI 7031L 1413 μS/cmcalibration solution, 500 mLHI 7032L 1382 ppmcalibration solution, 500 mLHI 7033L 84 μS/cmcalibration solution, 500 mLHI 721317 Hard carrying caseSPECIFICATIONS HI 97500RangeResolutionAccuracySensorBattery Type/LifeEnvironmentDimensionsWeight0.001 to 1.999 Klux; 0.01 to 19.99 Klux; 0.1 to 199.9 Klux0.001 Klux; 0.01 Klux; 0.1 Klux±6% of reading ±2 digitsHuman-eye-response silicon photodiodewith 1.5 m coaxial cable (fixed)9V AA/approx. 200 hours of continuous use;Auto-off after 7 minutes of non-use0 to 50°C (32 to 122°F); 100% RH164 x 76 x 45 mm (6.5 x 3.0 x 1.8'')180 g (6.3 oz.)ORDERING INFORMATIONHI 97500 is supplied with battery, protective case and instructions.(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com15


Portable Meters16HI 9828Probe availablein 4, 10 and 20 mcable lengths.Need a differentlength?Give us a call!HANNA’s iButton © TagIdentification Systemsimplifies test logging.iButton © s with a uniqueID can be installed atvarious sampling sites.When the matching connector of the meter contacts thebutton and measurements are logged, they are labeledwith the alphanumeric user-entered location ID.HANNA instruments ®T.I.S.TagIdentificationSystemHANNA’s HI 769828 multiparameter probe incorporates a built-in microprocessorand amplifiers that convert the high impedance signals from thesensors of the probe eliminating common problems associated with highimpedance signals such as limitation of cable length and noise. This allowsthe probe to have reliable communication with the meter and the user isimmediately warned of problems such as a broken cable.The probe also features HANNA’s Quick Calibration which allows the user tocalibrate pH and conductivity with one solution in a single, simple, step.Dissolved Oxygen is also calibrated in a single step in saturated air. Theprobe houses 7 of the 8 measured parameters: pH, pH mV, ORP, EC,Absolute EC, % saturation and mg/L (ppm) oxygen, and temperature.pH/ORP/EC/DO Multiparameter Meter• Graphic LCD with backlight can display up to12 parameters simultaneously• Meter features IP67 and probe features IP68waterproof protection• Exclusive T.I.S.—Tag Identification Systemsimplifies test logging• Quick Calibration feature calibrates all sensorswith one solution• Built-in barometer• Measurement check eliminates anyerroneous readings• Auto recognition of pH/ORP probe• LOGGER function memorizes the data of allconnected sensors• Log-on-demand and automatic logging(up to 60,000 samples)• Can display logged data as graphs• USB for PC connectivity• Auto-range of EC and TDS readings• Good Laboratory Practice feature with thelatest 5 calibrations recorded• Meter accepts both alkaline andrechargeable batteries• Rugged probe with stainless steel tip has adiameter under 2” for wells and pipesOur new multiparameter instrument monitors up to 13 different parameters(8 measured, 5 calculated), and comes complete with a waterproof (IP68),intelligent probe. The automatic logging feature stores up to 60,000 samples,which can then be downloaded to a PC via a USB port. The impactresistant, waterproof (IP67) meter has our exclusive Tag IdentificationSystem (T.I.S.) and will display logged data as graphs. Field calibration isincredibly easy with our all in one Quick Calibration solution (pH/EC/DO).THE GALVANICD.O. SENSORhas a built-in thermistor toprovide fast temperaturecorrected readings.THE 4-RINGCONDUCTIVITY SYSTEMensures stable conductivityreadings that are immuneto surface coating.All sensors arefield replaceableSENSOR REPLACEMENT ISQUICK AND EASY with screw typeconnectors and color coded sensors.THE METER AUTOMATICALLYRECOGNIZES the presence ofeither the pH or pH/ORP sensor.Both sensors have a cloth junctionwhich allows greater sensitivity,and are gel filled for improvedresistance to contamination.


Portable MetersSPECIFICATIONS HI 9828pHmV of pH inputORPDissolved OxygenConductivityResistivityTDSSalinitySeawater SpecificGravityAtm. PressureTemperatureCalibrationRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracy0.00 to 14.00 pH0.01 pH±0.02 pH±600.0 mV0.1 mV±0.5 mV±2000.0 mV0.1 mV±1.0 mV0.0 to 500.0% / 0.00 to 50.00 mg/L0.1% / 0.01 mg/L0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading;0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading0.000 to 200.000 mS/cm (actual EC up to 400 mS/cm)Manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cmAutomatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cmAutomatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm±1% of reading or ±1 μS/cm whichever is greater0 to 999999 W•cm; 0 to 1000.0 kW•cm; 0 to 1.0000 MW•cmDependent on resistivity reading0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt)Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt);0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)±1% of reading or ±1 mg/L0.00 to 70.00 PSU (extended Practical Salinity Scale)0.01 PSU±2% of reading or 0.01 PSU whichever is greater0.0 to 50.0 σt, σ0, σ150.1 σt, σ0, σ15±1 σt, σ0, σ15450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa±3 mmHg within ±15°C from the temperature during calibrationRange -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15KResolution 0.01°C; 0.01°F; 0.01KAccuracypHORPTemperature CompensationLogging MemoryLogging IntervalComputer InterfaceWaterproof ProtectionConductivity,SalinityD.O.Resistivity, TDS, σAtmos. PressureTemperature±0.15°C; ±0.27°F; ±0.15KAutomatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom bufferAutomatic at 1 custom pointAutomatic 1 point with 6 memorized standards (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)or custom pointAutomatic 1 or 2 points at 0, 100% or 1 custom pointBased on conductivity or salinity calibrationAutomatic at 1 custom pointAutomatic at 1 custom pointAutomatic from -5 to 55°C (23 to 131°F)Up to 60000 samples with 13 measurements each1 second to 3 hoursUSB (with HI 92000 software)Meter IP67, Probe IP68Environment 0 to 50°C (32 to 122°F); RH 100%Power SupplyDimensionsWeight(4) 1.5V alkaline C cells (approx. 150 hours of continuous use without backlight)/(4) 1.2V rechargeable C cells (approx. 70 hours of continuous use without backlight)Meter: 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”); Probe: 270 x 46 mm DIA (10.6 x 1.8” DIA)Meter: 750g (26.5 oz.); Probe: 750g (26.5 oz.)ORDERING INFORMATIONHI 9828 is supplied with HI 769828 pH/ORP/DO/EC/Temperature probe; HI 9828-25 quick calibration standard solution, 500 mL; probe maintenance kit; 4 rechargeable C size,Ni-MH batteries; power adapter & cable; car 12V accessory outlet adapter; (5) iButton © s with holder; calibration vessel, HI 7698281 USB interface cable; HI 92000 Windows ®compatible software and instruction manual in a rugged carrying case.(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com17


Portable MetersHI 98184 • HI 981845pH/ORP/ISE/Temp MultiparameterMeters• Direct measurement in multiple units (ppm, ppt,g/L, mg/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L,%w/v, user)• Calibration Check• 0.001 pH resolution• Stainless steel pH electrode with built-in temp. sensor• Relative mV scaleIn addition to all the features of the HI 9818x pH models mentioned earlier,these meters also include direct ion concentration determination with ISEs.These instruments have several advanced features: rechargeable batteries(alkaline batteries can also be used), inductive recharging (with a 115vstandard outlet or a 12V car adapter), our exclusive Calibration Check(electrode status), a 128 X 64 pixel graphic LCD, and comprehensive GoodLaboratory Practices (GLP), and IP67 waterproof casing. When using anISE with the HI 98184, the sensor parameter must be manually entered, andthe probe can be calibrated by one or two points with any of six standardbuffers. The HI 98185 allows direct probe choice and measurement unit,and the probe can be calibrated up to five points for increased accuracy.For our full line of ISE’s give usa call: (888) 815-6422 or visit usonline: www.hannainst.comUSBUNIVERSAL SERIAL BUSRechargeable batterieswith inductive rechargerThis model has up to 200 hour extendedbattery life to guarantee long operationin the field. When the batteries are low,you don’t have to worry about carrying aspare set with you—the batteries can berecharged with HANNA’s inductiverecharger. Simply leave the meter on therecharger for a few hours and you’reready to go. The recharger can either beplugged in a standard 115V socketusing the included HANNA adapter or a12 VDC source such as a car's 12 voltaccessory outlet.SPECIFICATIONS HI 98184 HI 98185pH-2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pHmV±2000 mVRangeFrom 1.00 x 10 -7 to 9.99 x 10 10ISEFrom 1.00 x 10-3 to 1.00 x 105 ppmconcentration (choice of units)Temperature-20.0 to 120.0 °C (-4.0 to 248.0°F)pH0.1; 0.01; 0.001 pHResolutionmV0.1 mVISE3 digits 0.01; 0.1; 1; 10 concentrationTemperature0.1°C (0.1°F)pH±0.01; ±0.002 pHAccuracymV±0.2 mVISE±0.5% of reading (monovalent ions), ±1% of reading (divalent ions)Temperature±0.4°C (±0.8°F) (excluding probe error)pHUp to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) +5 custom buffersCalibrationUp to 2 point calibration, 6 standardUp to 5 point calibration, 6 standardISEsolutions (0.1, 1, 10, 100, 1000, 10000 ppm)solutions (choice of units)Slope From 80 to 110%Temperature Compensation (pH)Manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)ProbesHI 72911B pH w/BNC and temperature combinedLoggingLog-on-demand 300 samplesPC ConnectivityOpto-isolated USB (with HI 92000 software)Input Impedance10 12 OhmsBattery Type/Life(4) 1.2V AA rechargeable batteries/approx. 200 hrs continuous use (without backlight)RechargerInductive recharger (included)Auto-offUser Selectable: 5, 10, 30, 60 min or can be disabledEnvironmentIP67Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)Weight525 gORDERING INFORMATIONHI 98184 and HI 98185 are supplied with HI 72911B combined pH/Temperature electrode, pH 4.01 and pH 7.01 buffer solutions;(4) 1.2V AA, 1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with power adapter; rugged carrying caseand instructions.Measurement ScreenDirect ISE readings shown in a choiceof units (HI 98185). LCD also displayselectrode type used, current temperature,remaining battery life, and timesimultaneously.ISE CalibrationUp to 5 point calibration with 6 standardsolutions. Users are guided throughthe calibration procedure with stepby-stepon-screen instructions.Good LaboratoryPracticeCalibration data, date and ID informationare stored for retrieval at a later time.18HANNA instruments ®


Portable MetersHI 991300 • HI 991301pH/EC/TDS/Temperature with 1 ProbeNo switchingmetersin the field!Perfect for freshwater applications; this meter allows the user to measure four vital parameterswithout having to change probes or recalibrate!SPECIFICATIONS HI 991300 HI 991301RangeResolutionAccuracy (@20°C/68°F)pH CalibrationEC/TDS CalibrationpH: 0.00 to 14.00; EC: 0 to 3999 μS/cm;TDS: 0 to 2000 ppm (mg/L); Temp.: 0.0 to60.0°C or 32.0 to 140.0°FpH: 0.01; EC: 1 μS/cm; TDS: 1 ppm;Temperature: 0.1°C or 0.1°FpH: 0.00 to 14.00; EC: 0.00 to 20.00mS/cm; TDS: 0.00 to 10.00 ppt (g/L);Temp.: 0.0 to 60.0°C or 32.0 to 140.0°FpH: 0.01; EC: 0.01 mS/cm; TDS: 0.01ppt; Temperature: 0.1°C or 0.1°FpH: ±0.01; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1.0°FAutomatic at 1 or 2 points with 2 sets of memorized standard buffers (pH4.01/7.01/10.01 or pHAutomatic, 1 point at 1382 ppm (CONV0.5) or at 1500 ppm (CONV 0.7) or at1413 μS/cm (others)Automatic, 1 point at 6.44 ppt (CONV 0.5)or at 9.02 ppt (CONV 0.7) or at 12880μS/cm (others)TDS Conv. Factor Selectable 0.45 to 1.00 with 0.01 increments (default 0.50)Temp. CompensationpH: automatic; EC/TDS: automatic, BETA (β) is adjustablefrom 0.0 to 2.4%/°C w/0.1 incrementsProbeHI 1288 pH/EC/TDS/Temp., DIN connector, 1 m (3.3’) cable (included)Battery Type/Life(4) 1.5V AAA/approx. 100 hrs of continuous useEnvironment0 to 50°C (32 to 122°F); 100% RHDimensions/Weight150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)/210g (7.4 oz.)ORDERING INFORMATIONHI 991300 and HI 991301 is supplied with HI 1288 pH/EC/TDS/T probe, with 1 m (3.3’) cable, batteries, rugged carrying case and instructions.ACCESSORIESHI 1288 pH/EC/TDS/Temperature probeHI 710007 Shockproof rubber boot, blueHI 710008 Shockproof rubber boot,orangeHI 70030P 12880 μS calibration sol.(25 x 20 ml)HI 70038P 6.44 ppt calibration solution(25 x 20 ml)HI 77100P 1413 μS/pH 7 calibrationsolution (10 x 20 mL each)HI 77200P 1500 ppm/pH 7 calibrationsolution (10 x 20 mL each)HI 77300P 1382 ppm/pH 7 calibrationsolution (10 x 20 mL each)HI 77400P pH 4; pH 7 calibrationsolution (5 x 20 mL each)HI 146-01°F Digital Thermometer• Cal-Check ® feature• Stainless steel probe• Allows for continuous monitoring• °C model availableSpot Checkor MonitorLightweightPortabilityA precision thermometer with stainless steel probe and Cal-Check ® . Use the optional probeholder (HI 750146) to mount the probe where it’s entirely hidden from main view but still easy tocheck the temperature of your tank (do not immerse the probe handle). More accurate than mostconventional aquarium thermometers, this meter will run without interruption for five years on asingle AA battery.SPECIFICATIONS HI 146-01Range-58.0 to 302.0°FResolution0.1°F (-58.0 to 199.9 °F),1°F (200 to 302 °F)Accuracy±0.5°F (4 to 194°C), ±1°F (outside)Probe (fixed)stainless steel, 160 x dia 3 mm (6.3 x dia 0.1’’), 2 m (6.6’) cableBattery type/life(1)1.5V AA / approx. 5 yearsEnvironment 32 to 122°F; RH max 95% 0 to 50°C; RH max 95% 0 to 50°C; RH max 100%Dimensions 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’)Weight150 g (5.3 oz)ORDERING INFORMATIONHI 146-01 is supplied with probe, battery and instructionsACCESSORIESHI 750146 Wall-mounted probe holder(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com19


Portable MetersHI 935005 • HI 935005NK-Type Thermocouple ThermometersWaterproof, Featuring Min, Max & HOLD• Measures in °C or °F• 1600 hours of battery life• High Range with auto-ranging• Auto-calibration and backlit LCD (HI 935005N only)This hand-held thermometer has a microprocessor and K-type sensor for the most accurate ofreadings. The backlit LCD screen simultaneously displays current temperature, as well as theminimum and maximum temperatures reached within a set time period. This model has an Autoofffeature, but it can be disabled and used as a constant monitoring device. One of the mostdistinguishing features of this meter is that the user can easily correct any combined meter andprobe interchange error by using the CAL button in an ice bath.SPECIFICATIONSHI 935005 • HI 935005NRange -50.0 to 199.9°C and 200 to 1350°C; -58.0 to 399.9°F and 400 to 2462°FResolutionAccuracyProbe0.1°C (-50.0 to 199.9°C) and 1°C (outside); 0.1°F (-58.0 to 399.9°F) and 1°F (outside)±0.2% F.S. (for 1 year, excluding probe error)K-thermocouple type, HI 766 series (not included). See opposite page bottomBattery Type/Life(3) 1.5V AA/approx. 1600 hours of continuous use (with backlight off);HI 935005 only: auto-off selectable after 8 or 60 minutes of non-use (can be disabled)Environment -10 to 50°C (14 to 122°F); RH max 100%Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)Weight235 g (8.3 oz.)ORDERING INFORMATIONHI 935005 is supplied complete with batteries, protectivecase and instructions.HI 935005N is supplied complete with batteries, protectivecase and instructions.ACCESSORIESHI 766E1 General purpose K-type temperature probewith 1 m cableHI 710007 Shockproof rubber boot, blueHI 710008 Shockproof rubber boot, orangeHI 99550-01InfraredThermometer• Ideal for spot checking& complete verificationof temperatures• Fast response time• Model available in °CIRTechnologyNon-IntrusiveSurface TemperatureMeasurementThis thermometer measures temperature with an infrared light beam, making it easy to measuretemperature in hard to reach places, like behind pipes and the center of large tanks. Due to thesensitive IR apparatus, this meter is the only one listed in this catalog that is not waterproof.TheHI 99550-01 comes with battery and instructions.SPECIFICATIONS HI 99550-01Range 14 to 572°FResolution 1°FAccuracy±2% of reading or ±3°FIR Response Time1 secondOptic IR Coefficient 3:1 ratio (ratio of distance to target diameter); Min. distance 30 mm (1.2”)Battery Type/Life(1) 9V/approx. 150 hours of continuous useDimensions 143 x 80 x 38 mm (5.6 x 3.1 x 1.5”)Weight320 g (11.3 oz.)ORDERING INFORMATIONHI 99556-01 is supplied with battery and instructions.ACCESSORIESHI 710004 Soft carrying caseHI 721316 Hard carrying caseHI 710007 Shockproof rubber boot, blueHI 710008 Shockproof rubber boot, orangeHI 731318 Sensor wipe tissues20HANNA instruments ®


Portable MetersdissolvedoxygenArguably the most importantparameter of water quality.Most species require a minimumof 3 ppm DO, 8-10 ppmis preferable. Unlike othergases such as nitrogen, oxygensupersaturation doesn’tusually result in gas bubbledisease (“pop-eye”), so highlevels generally aren’t anissue. Most of the meters listedhere are waterproof andcome with probes that can bereplaced by the user. Thatmeans there’s no need toreplace the entire meter orsend the unit in for costlyservicing if the probe or cablegets damaged. Simply twistoff the old cable, twist onthe new one, calibrate and go!All but one of the modelsfeatured here also comeequipped with automaticcalibration in air (at 100%),which means there are nocalibration screws, eliminatinga source of vapor infiltrationand prolonging the life ofthe meter.DO Levels at 100% SaturationTankTipSalinity (ppt)Temperature 0 10 20 30 4010 C / 50 F 13.0 12.2 11.4 10.6 9.815C / 59 F 10.3 9.7 9.2 8.6 8.120 C / 68 F 9.4 8.8 8.4 7.9 7.425 C / 77 F 8.5 8.0 7.6 7.2 6.730 C / 86 F 7.8 7.4 7.0 6.6 6.2Salt water at 75°F will containapproximately 6.8ppm (mg/L) of DO at 100%saturation. Levels of 125%DO saturation can occur ina reef environment with noill effects.Rechargeable batteries with inductive rechargerWhen the batteries are low, you don’t have to worry about carrying a spare set with you—the batteries can be recharged with HANNA’s optional inductive recharger. Simply leavethe meter on the recharger for a few hours and you’re ready to go. The recharger can eitherbe plugged in a standard 115V socket using the included HANNA adapter or a 12 VDCsource such as a car's 12 volt accessory outlet.SPECIFICATIONS HI 9147RangeO 2 : 0.0 to 50.0 mg/L; % Saturation O 2 : 0 to 600 %;Temperature: -5.0 to 50.0°CResolutionO 2 : 0.1 mg/L or 1%; Temperature: 0.1°CAccuracy (@20°C/68°F)O 2 : ±1% of reading; Temperature: ±0.2°CCalibrationManual, in saturated airTemp. CompensationAutomatic, -5 to 50°C (2332°F to 122°F)Salinity Compensation0 to 51 g/L (1 g/L resolution)Probe, fixed (included)HI 76409/4 with 4 m (13') cable (included) or HI 76409/10with 10 m (33') cableBattery Type/Life(1) 9V Ni-Mh, rechargeable/approx. 200 hours of continuous usewithout backlight; auto-off after 6 minutes of non-use;Environment0 to 50°C (32 to 122°F); 100% max RHDimensions196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')Weight500 g (1.1 lb.)HI 9147Dissolved Oxygen Meterwith Galvanic Probe• Designed for aquaculture• Backlit LCD• Automatic Temperature Compensation• Automatic salinity compensation• Water-resistantThis unit is unique among our family of DO meters inthat it comes with a galvanic probe. Unlike polarographicprobes, galvanic DO probes don’t requireany conditioning time when the unit is firstpowered on, saving time when many measurementsare required. The HI 9147 has automatictemperature compensation, and user adjustablealtitude and salinity compensation for the mostaccurate measurements. This unit comes withrechargeable batteries (inductive charger notincluded), though alkaline batteries can beused. A must have for systems with DOsensitive organisms or high bio-loads.ORDERING INFORMATIONHI 9147-04 is supplied with HI 76409/4 with 4 m (13’) cable, (5) spare membranes with O-rings, electrolyte solution (30 ml), rubberprotective boot, rechargeable battery, screwdriver and instructions.HI 9147-10 is supplied with HI 76409/10 with 10 m (33’) cable, (5) spare membranes with O-rings, electrolyte solution (30 ml), rubberprotective boot, rechargeable battery, screwdriver and instructions.ACCESSORIESHI 710040 Battery rechargerHI 76409A/P Membrane for HI 76409 probes series, 5 pcs.HI 76409/4* Galvanic D.O. probe with built-in temperature HI 7042S Electrolyte solution, 30 ml bottlesensor and 4 m cableHI 710015 Shockproof rubber boot, blue colorHI 76409/10* Galvanic D.O. probe with built-in temperature HI 710016 Shockproof rubber boot, orange colorsensor and 10 m cableHI 731326 Calibration screwdriver (20 pcs)HI 76409-0 Protective sleeve for HI 76409 probes series* To be substituted by authorized personnel only.In ChargeHI 710040Battery recharger(optional)(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com21


Portable MetersHI 98186DO Meter with Built-in BarometerUSBUNIVERSAL SERIAL BUS• Extended range up to 50 ppm and 600% saturation• Barometric pressure measurement• Salinity, pressure and temperature compensation• Direct D.O., BOD, OUR and SOURThis top of the line instrument has many fantastic features: rechargeablebatteries (alkaline batteries can also be used), inductive recharging (with a115v standard outlet or a 12V car adapter), a 128 X 64 pixel graphic LCD,and comprehensive Good Laboratory Practices (GLP), IP 67 waterproofcasing, extended ranges with automatic temperature and pressure compensation,and manual salinity compensation. This unit can log-on-demandup to 400 samples, and measure BOD (biochemical oxygen demand),OUR (oxygen uptake rate), and SOUR (specific oxygen uptake rate).BOD ParametersAll necessary parameters for BODtesting can be set and displayed atonce.SPECIFICATIONS HI 98186Dissolved Oxygen0.00 to 50.00 ppm; 0.0 to 600.0 % saturationRangeBarometric Pressure450 to 850 mmHgSalinity Compensation0 to 70 ppt (g/L)Temperature-20.0 to 120.0°CDissolved Oxygen0.01 ppm; 0.1% saturationResolution Barometric Pressure1 mm HgTemperature0.1°CAccuracyDissolved Oxygen0 to 300%: ±1.5% of reading or ±1.0%, whichever is greater; 300 to 600%: ±3% of reading;0 to 30 mg/L: ±1.5% of reading or 0.10 mg/L, whichever is greater;30 mg/L to 50 mg/L: ±3% of readingBarometric Pressure± 3 mmHg within ±15°C from the calibration pointTemperature±0.2°C (excluding probe error)Measurement ModesDirect D.O.; BOD (biochemical oxygen demand);OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)Dissolved OxygenAutomatic, 1 or 2 points or manual, 1 pointCalibration Pressure1 pointTemperature1 or 2 pointsTemperature CompensationAutomatic between 0.0 to 50.0°CProbeHI 76407/4F Polarographic with built-in temperature sensorLoggingLog-on-demand 400 samplesPC ConnectivityOpto-isolated USB (with HI 92000 software)Battery Type/Life(4) 1.2V AA rechargeable batteries/approx. 200 hrs continuous use (without backlight)RechargerInductive recharger (included)Auto-offUser Selectable: 5, 10, 30, 60 min or can be disabledEnvironmentIP67Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)Weight525 gBOD RecordsA list of all saved BOD data can beeasily retrieved and shown on theLCD display. Seed records have an“*” after the bottle ID.BOD ResultsBOD is calculated in mg per liter fromthe difference between the initial andfinal dissolved oxygen concentrationreadings.OUR ResultsMeasured in mg of oxygen consumedper liter per hour.Rechargeable batteries with inductive rechargerThis model has up to 200 hour extended battery life to guarantee long operation in the field.When the batteries are low, you don’t have to worry about carrying a spare set with you—thebatteries can be recharged with HANNA’s inductive recharger. Simply leave the meter on therecharger for a few hours and you’re ready to go. The recharger can either be plugged in astandard 115V socket using the included HANNA adapter or a 12 VDC source such as acar's 12 volt accessory outlet.ORDERING INFORMATIONHI 98186 is supplied with HI 76407/4F dissolved oxygen probe with built-in temperature sensor with 4 m (13’) cable; (2) sparemembranes; electrolyte solution; (4) 1.2V AA, 1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with poweradapter; rugged carrying case and instructions.SOUR ResultsMeasured in mg of oxygenconsumed per gram of volatilesuspended solids per hour.22HANNA instruments ®


Portable MetersHI 9146Dissolved Oxygen Meter for FieldApplications• Extended altitude compensation• Extended salinity compensation• Designed for the fieldThe extended altitude and salinity compensation makes this unit perfectfor brine or high altitude systems. Automatic calibration and temperaturecompensation with Hold button that freezes the reading on the LCD.Available with 4 meter or 10 meter probe cables (see ordering information).SPECIFICATIONS HI 9146RangeO 2 : 0.00 to 45.00 mg/L; % Saturation O 2 : 0.0 to 300.0%;Temperature: 0.0 to 50.0°CResolutionO 2 : 0.01 mg/L; % Saturation O 2 : 0.1% F.S.; Temperature: 0.1°CAccuracy (@20°C/68°F) O 2 : ±1.5% F.S.; % Saturation O 2 : 1.5% F.S.; Temperature: ±0.5°CCalibration Automatic, in air, at 100%Temp. CompensationAutomatic, 0 to 50°C (32°F to 122°F)Altitude Compensation0 to 4 km (0.1 km resolution)Salinity Compensation0 to 80 g/L (1 g/L resolution)ProbeHI 76407/4F polarographic, with 4 m (13') cable (included)Battery Type/LifeEnvironmentDimensionsWeight(4)1.5V AA/approx. 200 hours of continuous use;auto-off after 4 hours of non-use; or input for 12 Vdc power adapter0 to 50°C (32 to 122°F); 100% max RH196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')500 g (1.1 lb.)ORDERING INFORMATIONHI 9146-04 and HI 9146-10 is supplied with HI 76407/4F probe with 4 m (13') cable(HI 9146-04) or HI 76407/10F probe with 10 m (33') cable (HI 9146-10) with protective cap,2 spare membranes, HI 7041S electrolyte solution (30 mL), batteries, hard carrying caseand instructions.ACCESSORIESHI 7041S Refilling electrolyte solution (30 mL)HI 76407A/P Replacement membrane (5 pcs)HI 710005 115 VAC/12 VDC power adapter (US plug)HI 9145Extended Range D.O. Meter• Designed for harsh environments• Automatic calibration• Automatic temperature compensationIdeal for fresh water systems where altitude and salinity compensation is unnecessary, thismodel is equipped with all the other features of the HI 9146 that makes it so popular.SPECIFICATIONS HI 9145RangeResolutionO 2 : 0.00 to 45.00 mg/L; % Saturation O 2 : 0.0 to 300.0%;Temperature: 0.0 to 50.0°CO 2 : 0.01 mg/L; % Saturation O 2 : 0.1% F.S.; Temperature: 0.1°CAccuracy (@20°C/68°F)O 2 : ±1.5% F.S.; % Saturation O 2 : 1.5% F.S.;Temperature: ±0.5°CCalibration Automatic, in air, at 100%Temp. CompensationAutomatic, 0 to 50°C (32°F to 122°F)ProbeHI 76407/4 polarographic, with 4 m (13') cable (included)Battery Type/LifeEnvironmentDimensions/Weight(4)1.5V AA/approx. 200 hours of continuous use;auto-off after 4 hours of non-use; or input for 12 Vdc power adapter0 to 50°C (32 to 122°F); 100% max RH196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')/500 g (1.1 lb.)ORDERING INFORMATIONHI 9145 is supplied with D.O. probe HI 76407/4 with 4 m (13’)cable, 2 spare membranes, electrolyte solution HI 7041S (30mL), batteries, rugged carrying case and instructions.ACCESSORIESHI 7041S Refilling electrolyte solution (30 mL)HI 76407A/P Replacement membrane (5 pcs)(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com23


Portable MetersRelativeHumidity (RH)Hygrometers measure relative humidity (RH)in the surrounding air, an important factorwhere rapid environmental monitoring isrequired, such as in hydroponics and theemerging industries of aeroponics andaquaponics. It is also a vital task wheneverthere is a body of water near machinery orelectronics. As any aquaculturist or aquaristknows, any equipment with metal componentsnear a tank will rust out more quicklythan seems possible, whether it’s a steelgirder or computer chip.HI 9064 • hi 9065Relative Humidity /Temperature Meter• Water-resistant casing• High accuracy• Hold key• Displays temperature in °C and °F (HI 9065)The HI 9064 is a water-resistant meter that quickly measures RH with 98% accuracy. It featuressimple two point manual calibration, probe with two meter cable and a hold key that will instantlyfreeze readings on the LCD.The HI 9065 has all the great features of the HI 9064, but also measures temperature in °C or °F.24RH: 5.0 to 95.0%; Temperature: 0.0 to 60.0°C (32 to 140°F) upto 105°C (302°F) with HI 765 temperature probeSPECIFICATIONS HI 9064 HI 9065Range RH: 5.0 to 95.0%Accuracy (@20°C/68°F) RH: ±2%RH CalibrationRH ProbeHI 70608/2 with 2 m(6.6’) cable (included)Battery Type/LifeEnvironmentDimensions196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')Weight500 g (1.1 lb.)ORDERING INFORMATIONHI 9064 is supplied with HI 70608/2 RH probe with 2 m (6.6’)cable, batteries, rugged carrying case and instructions.HI 9065 is supplied with HI 70605/2 RH probe with internaltemperature sensor and 2 m (6.6’) cable, batteries, ruggedcarrying case and instructions.RH: ±2%; Temperature: ±0.4°C; ±1°F (for 1 year, excludingprobe error)Resolution RH: 0.1% RH: 0.1%; Temperature: 0.1°C; 1°FManual 2 point through trimmer on RH probeHI 70605/2 with built-in temperature sensor and 2 m (6.6’)cable (included)(4) 1.5V AA/approx. 500 hours of continuous use0 to 50°C (32 to 122°F); 100% max RHACCESSORIESHI 7101 Calibration chamberHI 7111/P Spare saturation LiCl salts forlow humidity calibration (15 g, 6 pcs)HI 7121/P Spare saturation NaCl saltsfor high humidity calibration (33 g, 6 pcs)


Chemical Test KitsChemical Test KitsThe Classic Standard of MeasurementHANNA instruments ® ’ Chemical Test Kits are economical, easy to use and practical in design.Each test kit comes with thorough instructions and everything necessary to perform quick andeasy tests.Parameter Part Number Method Range Smallest Increment Chemical Method # TestsAlkalinity HI 3811 Titration0-100 mg/L0-300 mg/L1 mg/L3 mg/LPhenophthaleinBromophenol blueAmmonia, fresh water HI 3824 Colorimetric 0-2.5 mg/L 0.5 mg/L Nessler 25Ammonia, fresh water HI 38049 Checker disc 0.0-3.0 mg/L 0.1 mg/L Nessler 100Ammonia, salt water HI 3826 Colorimetric 0.0-2.5 mg/L 0.5 mg/L Nessler 25Carbon Dioxide HI 3813 TitrationChloride HI 3815 TitrationChlorine, Free & Total HI 38017 Checker discCopper HI 38075 ColorimetricHardness, total HI 3812 Titration0-10.0 mg/L0-50.0 mg/L0-100 mg/L0-100 mg/L0-1000 mg/L0.00-0.70 mg/L0.0-3.5 mg/L0.00-0.25 mg/L0.0-6.0 mg/L0-30 mg/L0-300 mg/L0.1 mg/L0.5 mg/L1 mg/L1 mg/L10 mg/L0.02 mg/L0.1 mg/L0.05 mg/L1.2 mg/L0.3 mg/L3 mg/LPhenophthaleinMercuric Nitrate110 total110 total110 totalDPD 200Bicinchonic acid 100Hardness, total HI 3841 Titration 40-500 mg/L 20 mg/L EDTA 50Hardness, total and Calcium HI 38035 TitrationTotal: 0.0-20.0 gpgCa: 0.0-20.0 gpg0.2 gpg0.2 gpgIron HI 38340 Checker disc 0.0-5.0 mg/L 0.1 mg/L Phenanthroline 100Nitrate HI 3874 Colorimetric 0-50 mg/L 10 mg/L Cadmium reduction 100Nitrite HI 3873 Colorimetric 0.0-1.0 mg/L 0.2 mg/L Chromotropic acid 100Oxygen, dissolved HI 3810 Titration 0-10 mg/L 0.1 mg/L Modified Winkler 110Ozone HI 38054 Checker disc 0.0-2.3 mg/L 0.1 mg/L DPD 100pH HI 38058 Checker disc 4.0-10.0 mg/L 0.5 mg/L pH indicator 300Salinity HI 3835 Titration 0-40 g/kg 0.4 g/kg Mercuric Nitrate 110Zinc HI 38076 Checker Disk0.0-4.0 mg/L0.0-20.0 mg/L0.1 mg/L0.4 mg/LEDTAEDTAEDTAEDTA100100Zincon 100HI 3823 Combination Test Kit for AquacultureAlkalinity (as CaCO3)Titration0-100 mg/L0-300 mg/L1 mg/L3 mg/LPhenophthaleinBromophenol blue110 totalCarbon DioxideHardness (as CaCO3)TitrationTitration0-10.0 mg/L0-50.0 mg/L0-100 mg/L0-30 mg/L0-300 mg/L0.1 mg/L0.5 mg/L1 mg/L0.3 mg/L3 mg/LPhenophthaleinOxygen, dissolved Titration 0-10 mg/L 0.1 mg/L Modified Winkler 110pH Electronic pH tester 0.0-14.0 pH 0.1 pH ------ life of the meterSalinity Titration 0-40 g/kg 0.4 g/kg Mercuric Nitrate 110EDTAEDTA110 total110HI 3893 Aquarium Test KitAmmonia, fresh water Colorimetric 0-2.5 mg/L 0.5 mg/L Nessler 50Nitrate Colorimetric 0-50 mg/L 10 mg/L Cadmium reduction 50Nitrite Colorimetric 0.0-1.0 mg/L 0.2 mg/L Chromotropic acid 50pH Colorimetric 6.0-8.5 pH 0.5 pH pH indicator 501 gpg = 17 ppm CaCO3 1 mg/L = 1 ppm1g/kg = 1 g/L = 1 ppt 1 ppt = 1,000 ppm(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com25


PhotometersC 203C 200It Counts ToWater quality is the beginning and the end of fish health. Barelydetectable levels of contaminants can accumulate in you livestock’sbodies, making them more vulnerable to disease and stress. Vital traceelements often need to be maintained at levels too low for chemical kitsto accurately detect. Keep fish, plants, and invertebrates healthy andhappy by frequently testing with HANNA instruments’ line of ion specificphotometers. We make one for just about every possible analysis, frombromine to iodine to dissolved oxygen and more.Be SpecificHI 83203 (C 203)Multiparameter PhotometerDesigned for Aquaculture• Simple to use• Lightweight• Computer compatibleThis photometer is designed specifically for aquaculturalapplications containing those parameters* mostimportant to long term fish health.HI 83200 (C 200)A Complete Laboratory atyour Fingertips• Measures up to 36 parameters*• Lightweight• Computer compatibleComprehensive water quality analysis for 36 parameters*including heavy metals, nitrogenous wastes, andchemical contaminants.*Not all parameters will work correctly in salt water due to ionic interference with reagents.Reagents sold separately.** For Chlorine, liquid reagents are available. ‡ Reagents for 50 tests.All reagents with -01 final code are for 100 tests.TankTipCopper can be added to water throughmedications or tap water. If tap water is heldin copper tanks or flows through copperpipes, it may accumulate to toxic levels.Trace amounts of copper can be fatal toinvertebrates, and at the least will inhibitmolting of crustaceans. The level of copperin any aquatic system should be zero.PARAMETER SPECIFICATIONS*C 203 C 200 Test Range Method Reagent Code✔ Aluminum 0.00 to 1.00 mg/L Aluminon HI 93712-01✔ ✔ Ammonia MR 0.00 to 10.00 mg/L Nessler HI 93715-01✔ ✔ Ammonia LR 0.00 to 3.00 mg/L Nessler HI 93700-01✔ Bromine 0.00 to 8.00 mg/L DPD HI 93716-01✔ Chlorine Dioxide 0.00 to 2.00 mg/L Chlorophenol Red HI 93738-01✔ ✔ Chlorine**, Free 0.00 to 2.50 mg/L DPD HI 93701-01✔ ✔ Chlorine**, Total 0.00 to 3.50 mg/L DPD HI 93711-01✔ Chromium VI HR 0 to 1000 μg/L Diphenylcarbohydrazide HI 93723-01✔ Chromium VI LR 0 to 300 μg/L Diphenylcarbohydrazide HI 93749-01✔ Color 0 to 500 PCU Platinum Cobalt —✔ ✔ Copper HR 0.00 to 5.00 mg/L Bicinchoninate HI 93702-01✔ ✔ Copper LR 0 to 1000 μg/L Bicinchoninate HI 95747-01✔ Cyanide 0.000 to 0.200 mg/L Pyridine-Pyrazalone HI 93714-01✔ Cyanuric Acid 0 to 80 mg/L Turbidimetric HI 93722-01✔ Fluoride 0.00 to 2.00 mg/L SPADNS HI 93729-01✔ Hardness (calcium) 0.00 to 2.70 mg/L Calmagite HI 93720-01✔ Hardness (magnesium) 0.00 to 2.00 mg/L EDTA HI 93719-01✔ Hydrazine 0 to 400 μg/L p-Dimethylaminobenzaldehyde HI 93704-01✔ Iodine 0.0 to 12.5 mg/L DPD HI 93718-01✔ Iron HR 0.00 to 5.00 mg/L Phenantroline HI 93721-01✔ Iron LR 0 to 400 μg/L TPTZ HI 93746-01‡✔ Manganese HR 0.0 to 20.0 mg/L Periodate HI 93709-01✔ Manganese LR 0 to 300 μg/L PAN HI 93748-01‡✔ Molybdenum 0.0 to 40.0 mg/L Mercaptoacetic Acid HI 93730-01✔ Nickel HR 0.00 to 7.00 g/L Photometric HI 93726-01✔ ✔ Nitrate 0.0 to 30.0 mg/L Cadmium Reduction HI 93728-01✔ ✔ Nitrite HR 0 to 150 mg/L Ferrous Sulphate HI 93708-01✔ ✔ Nitrite LR 0.00 to 0.35 mg/L Diazotization HI 93707-01✔ Oxygen, Dissolved (D.O.) 0.0 to 10.0 mg/L Winkler HI 93732-01✔ ✔ pH 6.5 to 8.5 pH Phenol Red HI 93710-01✔ ✔ Phosphate HR 0.0 to 30.0 mg/L Amino Acid HI 93717-01✔ ✔ Phosphate LR 0.00 to 2.50 mg/L Ascorbic Acid HI 93713-01✔ Phosphorus 0.0 to 15.0 mg/L Amino Acid HI 93706-01✔ Silica 0.00 to 2.00 mg/L Heteropoly blue HI 93705-01✔ Silver 0.000 to 1.000 mg/L PAN HI 93737-01‡✔ Zinc 0.00 to 3.00 mg/L Zincon HI 93731-01SPECIFICATIONS HI 83203 (C 203) • HI 83200 (C 200)Light Source4 tungsten lamps with narrow band interference filter 420/525/575/610 nmLight Detector4 Silicon PhotocellsPower Supply(2) 9V battery or 12 Vdc adapterAuto-off after10 minutes of non-useEnvironment0 to 50°C (32 to 122°F);RHmax 95% non-condensingDimensions230 x 165 x 70 mmWeight640 gORDERING INFORMATIONHI 83203 and HI 83200 are each supplied with 2 cuvets, D.O.test bottle (HI 83200 only), batteries, 12 Vdc adapter and instructions.ACCESSORIESHI 92000 Windows ® compatible software26HANNA instruments ®


PhotometersHI 96711Free and Total ChlorinePhotometer with FastTracker• CAL CHECK validation• Exclusive Tag Identification System• Logging of up to 99 records• Supplied as a kit• Long battery life• Computer compatibleT.I.S.. — Tag Identification SystemInstall TAGs near your sampling points for quick andeasy iButton readings. Each TAG contains a computerchip with a unique identification code encased instainless steel. You can install a practically unlimitedamount of TAGs. Additional TAGs can be ordered for allof your traceability requirements.If you depend on municipal water for part or all of yourwater supply, then you must test it for chlorine. HI 96711measures free & total chlorine and features a quicktraceability system of the measured samples. Theadvanced optical system of the HI 96711 is based ona tungsten lamp and a narrow-band interference filterwhich allows highly accurate and repeatable readings.Thanks to i-Button © technology, this meter can associatea time and location label to every record. The i-Buttonis mounted on the top of the meter and you have just totouch the one that identifies the sample location beforeperforming each measurement. The check functionallows the user to validate the performance of theinstrument at any time. The meter can log up to 99measurements in the internal memory and all storeddata can be downloaded to a PC through the RS232serial port and the HI 92000 software. The sampletraceability system allows users to collect and managedata in a very simple and error free way; all measurementscan be quickly organized by time or by sample.SPECIFICATIONS HI 96711Free Chlorine -Range0.00 to 5.00 mg/LTotal Chlorine Range0.00 to 5.00 mg/LResolution0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/LPrecision±0.02 mg/L @ 1.00 mg/LLight SourceTungsten lamp with narrow band interference filter 525 nmLight DetectorSilicon PhotocellLOG Memory99 recordsSerial InterfaceRS232 @ 9600 baud ratePower Supply(4) 1.5V AA batteriesAuto-offAfter 10 min of non-use in measuring mode ; after 1 hour of non-use in calibration modeEnvironment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 216 x 83 x 65 mm (8.5 x 3.26 x 2.55”)Weight420 g (17 oz.)MethodAdaptation of the USEPA Method 330.5 and Standard Method 4500-Cl GiButtonORDERING INFORMATIONHI 96711 is supplied with 2 measurement cuvets and caps, (3) CAL CHECK cuvets, reagent powderpackets (10 ea.), tissue for wiping cuvets, (5) Tag holders with tags, (4) batteries, scissors, quick reference guideand instruction in a rugged carrying case.TraceabilityAssuranceTAGACCESSORIESHI 93701-01 Powder reagents for 100 tests (Free Chlorine)HI 93701-03 Powder reagents for 300 tests (Free Chlorine)HI 93711-01 Powder reagents for 100 tests (Total Chlorine)HI 93711-03 Powder reagents for 300 tests (Total Chlorine)HI 95701-11 Cal Check TM standard cuvets for free ChlorineHI 95711-11 Cal Check TM standard cuvets for total ChlorineHI 920005 Tag holders with tags (5 pcs)HI 731318 Tissue for wiping cuvets (4 pcs)HI 93703-50 Cuvet cleaning solution (230 mL)HI 731331 Glass measuring cuvets (4 pcs)HI 92000 Windows ® compatible softwareHI 920011 RS232 computer connection cable(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com27


PhotometersSupplied as aComplete Kit!see ordering informationHI 96 SeriesCAL CHECK Photometers• Large, dual-level LCD• Waterproof casing• Accuracy verification• User calibration• Certified calibration & verification standards• EPA compliant• Custom ranges to fit all applications• Long battery lifeThese are a number of single parameter photometers that are equipped with ourCal-Check ® feature. Many aquatic organisms commonly kept or raised are extremelysensitive to low levels of contaminants. It is therefore important to know that not only arethe instruments calibrated, but that they are calibrated correctly. The Cal-Check ® featureallows validation of the instruments.This series also features waterproof casing, a large dual-level LCD and advanced opticalsystem. The advanced optical system is based on a special tungsten lamp (modelHI 96715 features an LED) and a narrow band interference filter assuring accuratereadings every time.Cal-Check ® photometers are available for ammonia (HI 96715), free and total chlorine(HI 96711-HI 96762-HI 96761-HI 96724), nitrite (HI 96707), iron (HI 96721), and phosphate(HI 96717), among others. These photometers are accurate for fresh or saline water.Calibration Date on DisplayThe HI 96 series of photometers displays the last time calibration was performed so you may schedule routinecalibrations—ideal for ISO and Good Laboratory Practice environments.READ/TIME functionCounts down to appropriate time interval before a reading is displayed. This feature ensures consistencyin measurements across multiple users.28 HANNA instruments ®


PhotometersSPECIFICATIONS by modelParameter Code Range Precision Filter MethodAmmonia, Medium Range HI 96715Chlorine, Freefor Drinking WaterApplicationsChlorine, Free and Total HI 96724Chlorine, Totalfor the Analysis of TraceTotal Chlorine Concentration0.00 to 9.99 mg/L(as NH 3 -N)±0.12 mg/L @ 6.00 mg/L Narrow band @ 466 nmAdaptation of the ASTM Manual of Water andEnvironmental Technology, D1426-93, Nessler Method.HI 96762 0.000 to 0.500 mg/L ±0.004 mg/L @ 0.200 mg/L Narrow band @ 525 nm Adaptation of Standard Methods, 20th edition, 4500-Cl G.Free Cl 2 :0.00 to 5.00 mg/L;Total Cl 2 :0.00 to 5.00 mg/L±0.03 mg/L @ 1.00 mg/L Narrow band @ 525 nmAdaptation of the USEPA method 330.5 and StandardMethod 4500-Cl G.HI 96761 0.000 to 0.500 mg/L ±0.004 mg/L @ 0.200 mg/L Narrow band @ 525 nm Adaptation of Standard Methods, 20th edition, 4500-Cl G.Iron, High Range HI 96721 0.00 to 5.00 mg/L ±0.01 mg/L @ 1.50 mg/L Narrow band @ 525 nmAdaptation of the USEPA method 315B and StandardMethod 3500-Fe B.Nitrite, Low Range HI 967070.000 to 0.600 mg/L(as NO 2- -N)±0.001 mg/L @ 0.100 mg/L Narrow band @ 525 nm Adaptation of an EPA approved method.Phosphate, High Range HI 96717 0.0 to 30.0 mg/L ±0.5 mg/L @ 12 mg/L Narrow band @ 525 nmSPECIFICATIONS common to all modelsLight SourceEnvironmentBattery Type/LifeAuto Shut-offDimensions/WeightTungsten lamp; LED (HI 96715 only)0 to 50°C (32 to 122°F); Max 95% RH non-condensing(1) 9V/approx. 200 hours continuous useAfter 10 min. of non-use in measurement mode192 x 102 x 67 mm (7.6 x 4 x 2.6”)/290 g (10 oz.)Amino Acid Method, adapted from Standard Methodfor the Examination of Water and Wastewater.REAGENTSFor HI 96715:HI 95715-11 Cal Check TM standardHI 93715-01 Reagents for 100 testsHI 93715-03 Reagents for 300 testsFor HI 96761:HI 95761-01 Powder reagents for 100 tests (total chlorine)HI 95761-03 Powder reagents for 300 tests (total chlorine)HI 95761-11 Cal Check TM standardFor HI 96717:HI 95717-11 Cal Check TM standardHI 93717-01 Reagents for 100 testsHI 93717-03 Reagents for 300 testsFor HI 96762:HI 95762-01 Powder reagents for 100 tests (Free Chlorine)HI 95762-03 Powder reagents for 300 tests (Free Chlorine)HI 95762-11 Cal Check TM standardFor HI 96721:HI 93721-01 Reagent kit for 100 testsHI 93721-03 Reagent kit for 300 testsHI 95721-11 Cal Check TM standardFor HI 96724:HI 93701-T Liquid reagents for 300 tests of Total ChlorineHI 93701-F Liquid reagents for 300 tests of Free ChlorineHI 93711-D3 DPD3 reagent for 200 tests of Total ChlorineHI 95724-11 Cal Check TM standardFor HI 96707:HI 95707-11 Cal Check TM standardHI 93707-01 Reagents for 100 testsHI 93707-03 Reagents for 300 testsORDERING INFORMATIONHI 96xxx series of photometers are supplied with reagents, CAL CHECK standards, cuvet tissue, batteries, instruction manual and hard carrying case.ACCESSORIESHI 721310 9V battery (10 pcs)HI 731318 Tissue for wiping cuvets (4pcs)HI 731331 Glass cuvets (4 pcs)HI 731335 Caps for cuvets (4 pcs)HI 93703-50 Cuvet cleaning sol. (230 mL)Peace of mind—The CAL CHECKAssuranceWhen performing measurements you need to know thatthe instrument you are using is right on. With HANNA’sexclusive CAL CHECK feature you can now rest assured.Simply insert the factory calibrated standard of a knownconcentration and verify that your instrument is accurate.TankTipIron is an essential element for propergrowth of aquatic plants and macroalgae.The iron levels of a marine tank should be0.05 – 0.1 ppm; 0.25 – 0.5 for a fresh waterplanted aquarium.(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com29


Photometers30HI 93711RangeResolutionAccuracy (@20°C/68°F)Light SourceLight LifeLight DetectorBattery Type/LifeEnvironmentTankTipWeightNeutralize free chlorine with aSodium Thiosulfate solution.MethodHANNA instruments ®ORDERING INFORMATIONHI 93700 is supplied with 2 cuvets, battery and instructions.HI 93700C (kit) includes HI 93700, hard carrying caseand reagents.HI 93715 is supplied with 2 cuvets, battery and instructions.HI 93715C (kit) includes HI 93715, hard carrying caseand reagents.Free and Total Chlorine Photometer• Handheld for on-the-spot measurements• Lightweight• Available as a kit (See ordering information)If you depend on municipal water for part or all of your water supply, then you must test it for chlorine.You’ll always know when to treat your water with this easy to use, easy to read, hand-heldphotometer. Accurate in salt or fresh water.SPECIFICATIONS HI 93711Free Cl 2 0.00 to 2.50 mg/L; Total Cl 2 0.00 to 3.50 mg/L0.01 mg/L±0.03 mg/L ±3% of readingLED (Light Emitting Diode) 555 nmLife of the InstrumentSilicon Photocell(1) 9V/approx. 40 hours of continuous use; auto-off after 10 minutes of inactivity0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”)290 g (10 oz.)Method Adaptation of the EPA recommended DPD method 330.5.ORDERING INFORMATIONHI 93711 is supplied complete with 2cuvets, battery and instructions.HI 93711C (kit) includes HI 93711, hardcarrying case and reagents.HI 93700 • HI 93715Ammonia Photometers• Handheld for on-the-spot measurements• Lightweight• Available as a kit (See ordering information)ACCESSORIESHI 93701-01 Powder reagent kit for 100 tests (free chlorine)HI 93701-F Liquid reagent kit for 300 tests (free chlorine)HI 93701-T Liquid reagent kit for 300 tests (total chlorine)HI 93711-D3 DPD3 Reagent for 600 tests (total chlorine)HI 93701-11 Calibration standards 0.00, 0.25, 0.50,1.00 mg/L Free Cl 2 (4 pcs)HI 93703-50 Cuvet cleaning solution (230 mL)Use these portable, easy to operate photometers for precise and dependable ammoniareadings. Accurate in salt or fresh water.SPECIFICATIONS HI 93700 (Ammonia LR) HI 93715 (Ammonia MR)Range 0.00 to 3.00 mg/L 0.00 to 9.99 mg/LResolution 0.01 mg/L 0.01 mg/LAccuracy (@20°C/68°F ) ±0.04 mg/L ±4% of reading ±0.05 mg/L ±5% of readingLight SourceLED (Light Emitting Diode) 470 nmLight LifeLife of the instrumentLight DetectorSilicon PhotocellBattery Type/Life (1) 9V / approx. 40 hours of continuous use; auto-off after 10 minutes of inactivityEnvironment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”)Weight290 g (10 oz.)Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92,Nessler Method.ACCESSORIESHI 93700-01 Reagent kit for 100 tests (N-NH 3 LR)HI 93715-01 Reagent kit for 100 tests (N-NH 3 MR)HI 93733-01 Reagent kit for 100 tests (NH 4 + HR)HI 93703-50 Cuvet cleaning solution (230 mL)HI 710009 Shockproof rubber boot, blueHI 710010 Shockproof rubber boot, orangeHI 731318 Tissue for wiping cuvets (4 pcs)HI 93703-50 Cuvet cleaning solution (230 mL)HI 731321 Measuring cuvet (4 pcs)


PhotometersHI 93735Total Hardness Photometer• Measure total hardness in 3 scales• Readings expressed in ppm• LightweightTotal hardness (as Magnesium and Calcium) is a vital parameter for anyone keeping fish orshellfish. This meter, designed for fresh water use, employs a full range of hardness: ppm (mg/L)as well as French (°fH), German (°dH) and English hardness (°eH).SPECIFICATIONS HI 93735Range*ppm: 0 to 250 mg/L; 200 to 500 mg/L; 400 to 750 mg/LResolution1 mg/L (0 to 100 mg/L); 5 mg/L (100 to 750 mg/L)Accuracy (@20°C/68°F)±5 mg/L or ±4% of reading (0 to 250 mg/L); ±7 mg/L or 3% (200 to 500 mg/L);±10 mg/L or ±2% (400 to 750 mg/L)Light SourceLED (Light Emitting Diode) 470 nmLight LifeLife of the InstrumentLight DetectorSilicon PhotocellBattery Type/Life (1) 9V/approx. 40 hours of continuous use; auto-off after 10 minutes of inactivityEnvironment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”)Weight290 g (10 oz.)MethodAdaptation of the EPA 130.1 method* Also measures in °fH, °dH and °eHORDERING INFORMATIONHI 93735 is supplied complete with 2 cuvets, battery andinstructions.ACCESSORIESHI 93735-00 Reagent kit for 100 tests (0-250 mg/L)HI 93735-01 Reagent kit for 100 tests (200-500 mg/L)HI 93735-02 Reagent kit for 100 tests (400-750 mg/L)HI 93735-0 Reagent kit for 100 tests (0-750 mg/L)HI 93703-50 Cuvet cleaning solution (230 mL)TankTipPhosphates may be introduced by tap water, synthetic salt mixes, and some tankadditives. Excess phosphates are a cause of overgrowth of filamentous andslime algae. Chemical test kits may result in false positives, as phosphates areextremely difficult to remove from the plastic testing vials.HI 93713Phosphate Photometer• Handheld for on-the-spot measurements• Lightweight• Available as a kit (See ordering information)As any dedicated reef enthusiast knows, nutrients like phosphate can build up in a closed systemover time. This can cause blooms of unwanted (and possibly toxic) algae that can cause greatharm to a tank’s inhabitants. Avoid disaster by testing with HANNA’s precision photometer.SPECIFICATIONS HI 93713Range0.00 to 2.20 mg/LResolution0.01 mg/L)Accuracy (@20°C/68°F)±0.04 mg/L, ±4% of readingLight SourceLED (Light Emitting Diode) 890 nmLight LifeLife of the InstrumentLight DetectorSilicon PhotocellBattery Type/Life (1) 9V/approx. 40 hours of continuous use; auto-off after 10 minutes of inactivityEnvironment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”)Weight290 g (10 oz.)MethodAdaptation of the ascorbic acid methodORDERING INFORMATIONHI 93713 is supplied with 2 cuvets, battery and instructions.HI 93713C (kit) includes HI 93713, hard carrying caseand reagents.ACCESSORIESHI 93735-00 Reagent kit for 100 tests (0-250 mg/L)HI 93735-01 Reagent kit for 100 tests (200-500 mg/L)HI 93735-02 Reagent kit for 100 tests (400-750 mg/L)HI 93735-0 Reagent kit for 100 tests (0-750 mg/L)HI 93703-50 Cuvet cleaning solution (230 mL)HI 710009 Shockproof rubber boot, blueHI 710010 Shockproof rubber boot, orangeHI 731318 Tissue for wiping cuvets (4 pcs)HI 93703-50 Cuvet cleaning solution (230 mL)HI 731321 Measuring cuvet (4 pcs)(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com31


MonitorsHI 991401pH/Temperature Monitor Featuringa Large, Backlit LCD• Waterproof• Automatic calibration• Automatic temperature compensation• Stability indicator• 12 VDC power supplyDual-levelBacklit LCD!Continuously monitor the pH and temperature of any tank with this monitor.SPECIFICATIONS HI 991401RangeResolutionAccuracy (@20°C/68°F)pH: 0.0 to 14.0; Temperature: 0.0 to 60.0°C (32.0 to 140.0°F)pH: 0.1; Temperature: 0.1°C (0.1°F)pH: ±0.1; Temperature: ±0.5°C (±1°F)pH CalibrationAutomatic 1 or 2 point with 2 sets of memorized buffers(pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18)Temperature CompensationAutomaticProbesHI 1293D pH electrode (incl.) and HI 1294 temperature probe (incl.)Power Supply12 VDC adapter (included)Input Impedance10 12 OhmBattery LifeApprox. 2000 hours of continuous useEnvironment0 to 50°C (32 to 122°F); max. 95% RHDimensions 160 x 105 x 31 mm (6.3 x 4.1 x 1.2”)Weight (meter only)190 g (6.7 oz)ORDERING INFORMATIONHI 991401 is supplied with HI 1293D pHelectrode, fixed temperature probe, pH 4and pH 7 calibration solutions (20 mL ea.),12 Vdc adapter and instructions.ACCESSORIESHI 7004M pH 4.01 calibration sol., 230 mLHI 7007M pH 7.01 calibration sol., 230 mLHI 7010M pH 10.01 calibration sol., 230 mLHI 70300M Electrode storage sol., 230 mLHI 7061M Electrode cleaning sol., 230 mLHI 710005 115 VAC/12 VDC power adapterHI 9815pH Measurement on YourComputer• User friendly software• Allows continuous real-time datalogging• View results right on your PC monitorThe pH Turtle is a transmitter that turns your PC into apH meter! It comes complete with probe, RS 232 connector,and Windows compatible software. The PCinterface provides a continuously updated table oflogged data with real-time graph, audio and visualalarms. Perfect for monitoring effluent water quality forEPA compliance; also great for constant monitoring of ahome aquarium.SPECIFICATIONS HI 9815RangeResolutionAccuracy (@20°C/68°F)0.0 to 14.0 pH0.1 pH±0.2 pHCalibrationautomatic, at 1, 2 or 3 points directly from PC keyboardTemperature Compensationmanual, 0 to 100°C (32 to 212°F)pH ElectrodeHI 1333B (included)Input Impedance10 12 OhmEnvironment 0 to 50°C (32 to 122°F); RH max 95%Dimensions Ø 88 x 40 mm (Ø 3.5 x 1.6’’)Weight250 g (8.8 oz.)ORDERING INFORMATIONHI 9815 is supplied with HI 1333B pH electrode, windows ®compatible software, 1 m (3.3’) RS 232 connection cable andinstructions.ACCESSORIESHI 7007L pH 7.01 buffer solution, 500 mLHI 7010L pH 10.01 buffer solution, 500 mLHI 7082 Refilling electrolyte solution, 3.5 KCL, (4) 30 mLHI 70300L Electrode storage solution, 500 mLHI 7061L Electrode cleaning solution, 500 mLHI 70000P Electrode rinse sachets, 25 pcs32HANNA instruments ®


MonitorsHI 981401NpH Indicator with Large LCD & Water ResistantCasingThis pH monitor is easily hung from a hook by its molded eyelet. Small in size, it is still powerfulenough to serve the most demanding needs.Mount rightabove thesample!SPECIFICATIONSHI 981401NRange0.0 to 14.0 pHResolution0.1 pHAccuracy (@20°C/68°F)±0.2 pHpH Calibration Manual 1 point at pH 4 and 7pH ElectrodeHI 1286 plastic body, double junc., PTFE membrane, with 2 m (6.6’)cable & BNC conn. (incl.)Power Supply12 VDC adapter (included)Input Impedance10 12 OhmEnvironment0 to 50°C ; max. 100% RHDimensions (meter only) 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”)Weight150 g (5.3 oz)ORDERING INFORMATIONHI 981401N is supplied complete with HI 1286 pH electrode, 12 Vdc adapter, HI 1283 stainless steel groundingbar, pH 4 and pH 7 calibration solutions (20 mL each), calibration screwdriver and instructions.ACCESSORIESHI 7004M pH 4.01 calibration solution, 230 mLHI 7007M pH 7.01 calibration solution, 230 mLHI 7010M pH 10.01 calibration solution, 230 mLHI 77400P pH 4 and 7 sachets (20 mL, 5 ea.)HI 70300M Electrode storage solution, 230 mLHI 7061M Electrode cleaning solution, 230 mLHI 993301 • HI 993302EC/TDS/Temperature Monitorswith a Large Backlit LCD®• Waterproof• Adjustable TDS ratio• Adjustable β• Extra-large display• 12 VDC adapterThese sturdy, waterproof instruments are great for monitoring theefficiency of reverse osmosis and deionization units.Dual-levelBacklit LCD!SPECIFICATIONS HI 993301 HI 993302RangeResolutionAccuracy (@20°C/68°F)EC: 0 to 3999 μS/cm; TDS: 0 to 2000ppm; Temperature: 0.0 to 60.0°C or32.0 to 140.0°FEC: 1 μS/cm; TDS: 1 ppm;Temperature: 0.1°C or 0.1°FEC: ±2% F.S.; TDS: ±2% F.S.;Temperature: ±0.5°C or ±1°FEC: 0.00 to 20.00 mS/cm; TDS: 0.00 to10.00 ppt; Temperature: 0.0 to 60.0°C or32.0 to 140.0°FEC: 0.01 mS/cm; TDS: 0.01 ppt;Temperature: 0.1°C or 0.1°FEC: ±2% F.S.; TDS: ±2% F.S.;Temperature: ±0.5°C or ±1°FEC/TDS Calibration Automatic 1 point at 1413 μS/cm Automatic 1 point at 12.88 mS/cmEC/TDS Conv. Factor Adjustable from 0.45 to 1.00ProbeHI 7630 (included)Temp. CompensationAutomatic, BETA (b) is adjustable from 0.0 to 2.4%/°CPower Supply12 VDC adapter (included)Environment0 to 50°C (32 to 122°F); max 95% RHDimensions 160 x 105 x 31 mm (6.3 x 4.1 x 1.2”)Weight (meter only)190 g (6.7 oz.)ORDERING INFORMATIONHI 993301 is supplied with HI 7630 EC probe, 1413 μS/cmcalibration solution (20 mL), 12 Vdc adapter and instructions.HI 993302 is supplied with HI 7630 EC probe, 12.88 mS/cmcalibration solution (20 mL), 12 Vdc adapter and instructions.ACCESSORIESHI 7030M 12.88 mS/cm calibration solution, 230 mL bottleHI 70030P 12.88 mS/cm cal. solution, 20 mL sachet, 25 pcsHI 7031M 1413 μS/cm calibration solution, 230 mL bottleHI 70031P 1413 μS/cm cal. solution, 20 mL sachet, 25 pcsHI 7032M 1382 ppm calibration solution, 230 mL bottleHI 70032P 1382 ppm cal. solution, 20 mL sachet, 25 pcsHI 7038M 6.44 ppt, calibration solution, 230 mL bottleHI 70038P 6.44 ppt calibration solution, 20 mL sachet, 25 pcs(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com33


MonitorsMount rightabove thesample!HI 983302NEC Monitor Featuring a Large LCD &Water Resistant CasingThe Gro’Chek EC monitor is easily placed above a sump or tank, where itswater resistant casing protects it from accidental splashing. The submersionelectrode guarantees accurate results.SPECIFICATIONSRangeResolutionAccuracy (@20°C/68°F)CalibrationTemperature Comp.ProbePower SupplyInput ImpedanceEnvironmentHI 983302N0.00 to 9.99 mS.cm0.01 mS.cm±0.2% F.S.Manual 1 point through trimmerAutomatic, 5 to 50°C (41 to 122°F) with b=2%/°CHI 7632 with 2 m (6.6’) cable (included)12 VDC adapter (included)10 12 Ohm0 to 50°C (32 to 122°F); max. 100% RHDimensions (meter only) 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”)Weight215 g (7.6 oz)®TDS Versions AvailableHI 983301N w/0.7 conv. fac.HI 983301N/5 w/0.5 conv. fac.ORDERING INFORMATIONHI 983302N is supplied with HI 7632 probe, 12 Vdc adapter, 1413 μ/cm calibrationsolution (20 mL), calibration screwdriver and instructions.ACCESSORIESHI 70031P 1413 μS/cm calibration solution, 20 mL sachet, 25 pcsHI 991404 • HI 991405Combo pH, EC/TDS and TemperatureMonitor with Large Backlit LCD• Waterproof• Adjustable TDS ratio• Adjustable βKnow the parameters of your water at a glance! pH, EC, TDS and temperature in one monitor; thedual level, back-lit display shows temperature and pH or EC/TDS. This unit has ATC for both pHand EC/TDS, with a user adjustable EC/TDS conversion factor.SPECIFICATIONS HI 991404 HI 991405RangeResolutionpH: 0.00 to 14.00; EC: 0 to 3999 μS/cm;TDS: 0 to 2000 ppm; Temperature: 0.0to 60.0°C or 32.0 to 140.0°FpH: 0.01; EC: 1 μS/cm; TDS: 1 ppm;Temperature: 0.1°C or 0.1°FpH: 0.00 to 14.00; EC: 0.00 to 20.00 mS/cm;TDS: 0.00 to 10.00 ppt; Temperature: 0.0 to60.0°C or 32.0 to 140.0°FpH: 0.01; EC: 0.01 mS/cm; TDS: 0.01 ppt;Temperature: 0.1°C or 0.1°FAccuracypH: ±0.05; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1°FpH Calibration1 or 2 points with 2 sets of memorized buffersEC/TDS CalibrationAutomatic 1 pointEC/TDS Conv. Factor Adjustable from 0.45 to 1.00Temp. Compensation pH: automatic; EC/TDS: automatic, BETA (β) is adjustable from 0.0 to 2.4%/°CBattery TypeBattery LifeEnvironmentDimensions/Weight• Stability indicator• Extra-large display• 12 VDC power supply(4) 1.5V with BEPS (Battery Error Prevention System)Approx. 100 hrs of continuous use; auto shut-off after 8 minutes of non-use0 to 50°C (32 to 122°F); 100% RH163 x 40 x 26 mm (6.4 x 1.6 x 1”)/85 g (3.0 oz.)Dual-levelBacklit LCD!ORDERING INFORMATIONHI 991404 is supplied with HI 1293D pH electrode, fixedHI 7630 probe, pH and EC calibration solutions, 12 Vdc power adapterand instructions.HI 991405 is supplied with HI 1293D pH electrode, fixedHI 7630 probe, pH and EC calibration solutions, 12 Vdc power adapterand instructions.ACCESSORIESHI 7004M pH 4.01 calibration solution, 230 mLHI 7007M pH 7.01 calibration solution, 230 mLHI 7010M pH 10.01 calibration solution, 230 mLHI 7030M 12.88 mS/cm calibration solution, 230 mLHI 7031M 1413 μ/cm calibration solution, 230 mLHI 7032M 1382 ppm calibration solution, 230 mLHI 70038P 6.44 ppt calibration solution, 20 mLsachet, 25 pcsHI 70442M 1500 ppm calibration solution, 230 mLHI 70300M Electrode storage solution, 230 mLHI 7061M Electrode cleaning solution, 230 mLHI 710005 115 VAC/12 VDC power adapter34HANNA instruments ®


MonitorsHI 981504pH/TDS/TemperatureMonitor• 3 backlit LCDs• Measure in °C or °F• 12 VDC power supplyHI 148Temperature Indicator withBuilt-in LED Alarm Signal• Continuous ambienttemperature monitoring• Visible LED alarm• User-selectable alarm set pointThis temperature indicator has an LCD display and anLED alarm, which lights up when the temperatureexceeds the user-selectable set point. It has a moldedeyelet for easy mounting on a panel or wall. It comeswith probe, battery and instructions.Two models are available:• HI 981504/5 with 0.5 TDS factor• HI 981504/7 with 0.7 TDS factorVery similar to our GroChek monitors, this model has three separate, backlit, LCD screens tosimultaneously display three very important parameters. This monitor is adaptable for multipleapplications. It is a must have for sensitive freshwater applications such as breeding discus or raisingcichlids. It is also great for continuous monitoring of reverse osmosis water dosing systems.This monitor is incredibly simple to use: simply install it above the sampling site, plug it in,and immerse the probes. pH, TDS, and temperature are measured and displayed on the large,easy to read LCD screens. Temperature can be displayed in °C or °F by means of a switch onthe back panel.SPECIFICATIONSHI 148-01 (°F) • HI 148-00 (°C)RangeHI 148-01: -4.0 to 140°F;HI 148-00: -20.0 to 60.0°CResolutionHI 148-01: 0.1°F; HI 148-00: 0.1°CAccuracyHI 148-01: ±0.9°F; HI 148-00: ±0.5°CSetpointHI 148-01: Selectable from 32.0 to 122.0°F;HI 148-00: Selectable from 0.0 to 50.0°CAlarmLED blinks when measured temperature ishigher than the set pointSensorIncorporated, encapsulated stainless steelPower Supply 12 VDC external power adapter (included)Dimensions 86 x 94 x 33 mm (3.3 x 3.7 x 1.3”)Weight150 g (5.2 oz.)ORDERING INFORMATIONHI 148-00 is supplied with 12 VDC adapter and instructions.HI 148-01 is supplied with 12 VDC adapter and instructions.The HI 1286 gel-filled pH electrode is provided with a waterproof sheath to protect the BNCconnector. The unique design of the electrode provides longer life in aggressive solutions. TheHI 7634 TDS probe is easy to clean and requires little maintenance. Measurements are accurateand the meter can be calibrated at one or two points for pH and at a single point for TDS.Temperature range is factory calibrated.SPECIFICATIONS HI 981504RangeResolutionAccuracypH CalibrationTDS CalibrationpH: 0.0 to 14.0; TDS: 0 to 1990 ppm; Temperature: -10.0 to 60.0°C or -14.0 to 140.0°FpH: 0.1; TDS: 10 ppm; Temperature: 0.1°C or 0.1°FpH: ±0.2; TDS: ±2% F.S.; Temperature: ±0.3°C or ±0.5°FManual 2 points through trimmersManual 1 point through trimmerTDS Factor 0.5 (HI 981504/5) or 0.7 (HI 981504/7)ProbesTemp. CompensationPower SupplyEnvironmentDimensions/WeightpH: HI 1286 (included); TDS: HI 7634 (fixed); Temp.: Stainless steel, 2 m cable (fixed)Automatic, 5 to 50°C (41 to 122°F), for TDS readings only12 VDC power adapter (included)0 to 50°C (32 to 122°F); 95% RH160 x 110 x 35 mm (6.3 x 4.3 x 1.4”)/560 g (1.2 lb.)ORDERING INFORMATIONHI 981504 is supplied with HI 1286pH electrode, HI 7634 TDS probe,temperature probe, TDS sachet, (2)cleaning solution sachets, screwdriver,12 Vdc power adapter and instructions.ACCESSORIESHI 1286 Double junction, plastic body pH electrode with2 m (6.6’) cable and BNC connector.HI 7004M pH 4.01 calibration solution, 230 mLHI 7007M pH 7.01 calibration solution, 230 mLHI 7010M pH 10.01 calibration solution, 230 mLHI 7032M 1382 ppm calibration solution, 230 mLHI 70442M 1500 ppm calibration solution, 230 mLHI 70300M Electrode storage solution, 230 mLHI 7061M Electrode cleaning solution, 230 mLHI 731326 Calibration screwdriver, 20 pcs(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com35


Monitoring & Control24/7Any system can be costeffectively monitored24 hours a day.BL SeriesMini ControllersThe Perfect Solution forWater Analysis and Control• Panel mounted• Selectable overdose protection system• External disable feature• Selectable control override• Matching pin connection• 4-20 mA analog outputCONDUCTIVITY ORP pHFit BL Series Mini Controllers into our custom NEMA boxes! (opposite page)SPECIFICATIONS BL 981411-0 • BL 981411-1 BL 931700-0 • BL 931700-1Range 0.0 to 14.0 pH 0.00 to 14.00 pHResolution 0.1 pH 0.01 pHAccuracy (@20°C/68°F) ±0.1 pH ±0.02 pHTypical EMC Deviation ±0.1 pH ±0.10 pH/±0.10 mACalibration Manual, through CAL (offset) trimmer Manual, through offset & slope trimmersDosing ContactMaximum 2A (fuse protected), 250 VAC, 30 VDCDosing SelectionAcid or Alk, selectable on the back panelContact Open=Acid dosage=Relay ON if Measure > SetpointContact Close=Alk dosage=Relay ON if Measure < SetpointSetpoint Adjustable, from 0.0 to 14.0 pH Adjustable, from 0.00 to 14.00 pHRecorder Output -4 to 20 mA, accuracy ±0.20 mA,500 W maximum loadSPECIFICATIONS BL 982411-0 • BL 982411-1 BL 932700-0 • BL 932700-1Range 0 to 1000 mV ±1000 mVResolution 1 mV 1 mVAccuracy (@20°C/68°F) ±5 mV ±5 mVTypical EMC Deviation ±5 mV ±0.10 pH/±0.10 mACalibrationManual, through CAL trimmerDosing ContactMaximum 2A (fuse protected), 250 VAC, 30 VDCDosing SelectionRdx or Oxd, selectable on the back panelContact Open=Reductant dosage=Relay ON if Measure > SetpointContact Close=Oxidant dosage=Relay ON if Measure < SetpointSetpoint Adjustable, from 0 to 1000 mV Adjustable, from -1000 to 1000 mVRecorder Output -4 to 20 mA, accuracy ±0.20 mA,500 W maximum loadSPECIFICATIONS BL 983317-0 and BL 983317-1 BL 983313-0 • BL 983313-1Range 0.00 to 10.00 mS/cm 0 to 1999 μS/cmResolution 0.01 mS/cm 1 μS/cmAccuracy (@20°C/68°F) ±2% f.s. ±2% f.s.Typical EMC Deviation ±2% f.s. ±2% f.s.Probe HI 7632-00 EC/TDS probe (optional) HI 7634-00 EC/TDS probe (optional)Temp. CompensationAutomatic from 5 to 50°C (41 to 122°F); β=2%/°CCalibrationManual, through CAL trimmerDosing ContactMaximum 2A (fuse protected), 250 VAC, 30 VDCContact close when measure < Setpoint Contact close when measure > SetpointSetpoint Adjustable, from 0 to 10 mS/cm Adjustable, from 0 to 1999 μS/cmWhether you’re running a small research system orhuge commercial tanks, if you’re using recirculatingwater you’re going to need a controller. Our popular lineof HI mini-controllers has been completely redesignedand renamed (BL) in honor of our rugged BlackstonePump series. Use these mini-controllers for eitherdosage or alarm systems; use our state of the artmicroprocessor controllers for both! Available for pH,ORP, EC, TDS or water level. Order a NEMA box (formini-controllers only) or our custom made industrialpanels for protection against damage and we’ll create acustomized, pre-wired control system. Whether it’s for asingle mini-controller or a dozen microprocessors, allyou have to do is plug it in! Please see our website,www.hannainst.com, or our general catalog for a full listof our many BL minicontrollers.• Removable modulesfor easy maintenanceSPECIFICATIONSOvertimePower ConsumptionInstallation CategoryPower supply:BL XXXXXX-0BL XXXXXX-1All Models• 2 ampbuilt-in fuse• Quick-connectterminal blocksAdjustable, typically from 5 to approx. 30 min.10 VAIIExternal (fuse protected)12 VDC115/230 VAC (fuse protected); 50/60 HzDimensions 79 x 49 x 95 mm (3.1 x 1.9 x 3.7”)ORDERING INFORMATIONBL 98XXXX-0 are supplied with mounting brackets, transparentcover, 12 VDC power adapter and instructions.BL 98XXXX-1 are supplied with mounting brackets, transparentcover and instructions.36HANNA instruments ®


Monitoring & ControlMake yourown controland injectionsystemsHI 1211 • HI 1222Controller & Monitors inour Industrial Enclosure• NEMA protection• LCD display• Alarm contact• Key pad touch setting• Calibration and adjustable set points• Multi-ranges for TDS and conductivity• Available in 115 V or 12 VDC• Simple to Install - just plug in probe, power &relay meter and you’re in business!Choose from the singlecapability HI 1211 or thedual capability HI 1222Choose from TDS, Conductivity, pH, Resistivity or ORP. Thesecontrollers will allow any system to be cost effectively monitored24 hours a day.HI 7871 • HI 7873Level ControllersHI 1211 with single meter capabilityThese mini level controllers are ideal for monitoringwater levels in sumps, tanks, and bioreactors. TheHI 7871 controls high and low levels, and the HI 7873controls high, low and overflow. A complete liquid levelmeasuring system requires the controller (HI 7873 orHI 7871), a bar holder/transmitter with amplifier(HI 7874), a package of measuring bars (HI 731324),and an undecal connector (HI 7164). The transmitterallows remote monitoring up to 300m away.HI 1222 with dual meter capabilityCombine our BL seriesmini controllers(shown on opposite page)into our HI 1222for versatile monitoringand control!SPECIFICATIONS HI 7871 HI 7873TransmissionMax 100 meters (330 feet)Electrical ConnectionHI 7164 undecal connector (not included)Level Adjustment High and low High, low and overflowLevel Indication High and low High, low and overflowSensor Bars 3, HI 731324 (not incl.) (See accessories) 4, HI 731324 (not incl.) (See accessories)TransmitterOutput ContactPower SupplyORDERING INFORMATIONHI 7871/115 (115 Vac) is supplied with mounting brackets and instructions.HI 7871/220 (220 Vac) is supplied with mounting brackets and instructions.HI 7873/115 (115 Vac) is supplied with mounting brackets and instructions.HI 7873/220 (220 Vac) is supplied with mounting brackets and instructions.ACCESSORIESHI 7874 Level transmitter with internal amplifierHI 7164 Undecal connectorHI 731324 Stainless steel threaded measuring bars (5 pcs.)HI 7874 (not included)1 relay (2A/250 Vac, 30 Vdc) 2 relays (2A/250V, 30 Vdc)Models “/115”: 110/115 Vac; 50/60Hz; models “/220”: 220/240 Vac; 50/60HzEnvironment0 to 50°C (32 to 122°F); RH max 85% non condensingDimensions 83 x 53 x 95 mm (3.1 x 1.9 x 3.8’’)Weight250 g (8.8 oz.)(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com37


Monitoring & Control38SPECIFICATIONS HI 504Range-2.00 to 16.00 pH; -2000 to 2000 mV; -30 to 130.0°CResolution0.01 pH; 1 mV; 0.1°C (above -10 °C); 1°C (below -10°C)Accuracy (@20°C/68°F)±0.02 pH; ±2 mV; ±0.5°C (-9.9 to 130.0°C); ±1°C (-30 to -10°C)Input ImpedanceDigital OutputIsolated output; contact closed upon Hold modeAnalog Output1 or 2 independent outputs (configuring as 0-20 mA or 4-20 mA)HI 50410 12 OhmHI 7610 Stainless steel temp. probewith Pt100 sensor and 5 m cableHI 7611 Stainless steel temp. probewith Pt1000 sensor and 5 m cableHI 7004/1L pH 4.01 buffer solution, 1 LHANNA instruments ®Dosing and Alarm RelayElectromechanical relay SPDT contact output ; 5A - 250 Vac, 5A - 30 Vdc (resistiveload); fuse protected: 5A, 250V “Quick Blow” fuseTemp. Compensation Automatic or manual, -30 to 130°CTemperature ProbePt100/Pt1000 sensor (with automatic recognition and damage test)Power Supply24 VDC/AC; 115 Vac ±10%, 230 Vac ±10%, 100 Vac ±10%; 50/60 HzEnvironment0 to 50°C (32 to 122°F); RH max 85% non-condensingCasingIP54 (front panel)Dimensions / Weight Panel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm / 1.6 kg (3.5 lb.)ORDERING INFORMATIONEach HI 504 model is supplied with mounting brackets and instruction manual.ACCESSORIESHI 504900 GSM module*HI 504901 GSM supervisorHI 504902 RS485 modem (PSTN)HI 504910 Digital transmitterHI 92500 Windows ® compatible softwarepH/ORP Controller with Tele-Controland Sensor CheckThe ultimate in system control (pH or ORP)Features include:• The RS 485 interface allows up to 32 instruments to be networked to acomputer and controlled remotely• Sensor Check feature reports the nature of a breakdown, includingdamaged probe, dirty junction, contaminated reference, etc…• Auto-cleaning cycle to control deposits on the probe bulb• “Fail Safe” alarm system for hardware and software• Digital transmitter and GSM cellular module (sold separately)Sensor Check TM pH/ORPAs part of the powerful self-diagnostic functions of this instrument series, the Sensor Check system provides continuous inspection of probe status. Thetest is not limited to a simple signal that indicates an error in progress, but it reports the nature of the breakdown with a specific error code. With the use ofthe HI 504900 GSM module, errors or alarms can be sent directly to the operator's mobile phone as an SMS message.Here are the types of breakdowns shown by sensor check:> pH electrode broken> Reference electrode dirty> Reference electrode or matching pin not immersed> Electrode junction dirty or clogged> Short-circuit between cables of pH and reference electrodes> Signal problems from the cable or connector due to humid or dirty environmentsThe internal circuit of the instrument executes two independent tests, one for the probe and one for the reference chamber, measuring the respective impedancevalues every 30 seconds. These tests last for a very short period to avoid electrolysis and polarization, which can be caused by a prolonged exposureto an electric current.HI 504XYZ-aHI 7006/1L pH 6.86 buffer solution, 1 LHI 7007/1L pH 7.01 buffer solution, 1 LHI 7009/1L pH 9.18 buffer solution, 1 LHI 7010/1L pH 10.01 buffer solution, 1 LHI 7020L 200-275 mV test solution, 500 mLX=1, single setpointX=2, dual setpointX=8, single setpoint & advanced cleaningX=9, dual setpoint & advanced cleaningY=1, ON/OFF controlY=2, ON/OFF & PID controlZ=2, single analog outputZ=4, dual analog outputa=0, 24 VDC/AC power supplya=1, 115VAC power supplya=2, 230VAC power supplya=3, 100VAC power supply* Compatible phones, plans & SIM cards must be purchased separately from an outside provider and is not in any way covered by HANNA instruments ®Receive electrode status& diagnostic messages on the LCDdisplay or via your mobile phone!*Broken electrode Dirty electrode Electrode not immersedMatch the last letters in the product code to the correspondingnumbers according to desired configuration.HI 7091L Reducing solution, 500 mLHI 7092L Oxidizing solution, 500 mL


Monitoring & ControlHANNA ControllersThese state-of-the-art microprocessor pH, mV and EC/TDS panel mount controllers have literally dozens of options, allowing the userto create exactly the system they need.Options include computer interfaces (RS 232 or RS 485), analog outputs, ON/OFF or proportional dosing response, 115 or 230 Vac forthe United States or overseas, single or dual setpoints, and more!pH 500pH Control• Simple to operate• Automatic calibration• 3 month backup power supplySPECIFICATIONS pH 500Range 0.00 to 14.00 pH; -9.9 to 120°CResolution0.01 pH; 0.1°CAccuracy (@20°C/68°F)±0.02 pH; ±0.5°CInput Impedance10 12 OhmpH Calibration automatic, 1, 2 or 3 point, at pH 4.01, 7.01, 10.01Temp. Compensation automatic (with Pt100 probe) or manual from -9.9 to 120°COutputsSetpoint RelayPower SupplyEnvironmentDimensionsWeightdigital: RS232 bi-directional optoisolated; or analog, galvanically isolated:0-1 mA, 0-20 mA and 4-20 mA, 0-5 Vdc, 1-5 VDC and 0-10 VDC1 or 2 contact outputs SPDT 5A-250 VAC,5A-30 VDC (resistive load)115 Vac ±10% or 230 Vac ±10%; 50/60 Hz0 to 50°C (32 to 122°F); RH max 95% non-condensingpanel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm1.6 kg (3.5 lb.)ORDERING INFORMATIONEach pH 500 model is supplied with mounting brackets andinstruction manual.pH 500XYZ-aX=1, single setpointX=2, dual setpointMatch the last letters in the product code to the corresponding numbersaccording to desired configuration.Y=1, ON/OFF controlY=2, proportional controlZ=1, analog outputZ=2, RS232 outputa=1, 115VAC power supplya=2, 230VAC power supplymV 600ORP Control• User-friendly• Automatic calibration• 3 month backup power supplySPECIFICATIONS mV 600Range -2000 to 2000 mV; -9.9 to 120°CResolution1 mV; 0.1°CAccuracy (@20°C/68°F)±2 mV; ±0.5°CInput Impedance10 12 OhmORP Calibrationautomatic, at 0 and 350 or 1900 mVOutputsdigital: RS232 bi-directional optoisolated; or analog, galvanically isolated:0-1 mA, 0-20 mA and 4-20 mA, 0-5 Vdc, 1-5 Vdc and 0-10 VdcSetpoint Relaycontact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load)Power Supply115 Vac ±10% or 230 Vac ±10%; 50/60 HzEnvironment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensionspanel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mmWeight1.6 kg (3.5 lb.)ORDERING INFORMATIONEach mV 600 model is supplied complete with mountingbrackets and instruction manual.mV 600XYZ-aX=1, single setpointMatch the last letters in the product code to the corresponding numbersaccording to desired configuration.Y=1, ON/OFF controlY=2, proportional controlZ=1, analog outputZ=2, RS232 outputa=1, 115VAC power supplya=2, 230VAC power supply(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com39


Monitoring & ControlHI 700 • HI 710Microprocessor Conductivityand TDS Controllers with 4-ringPotentiometric Probe• Accurate, reliable and simple to install• Extensive range for both conductivity and TDS• Programmable through menu-driven display• Selectable isolated output in mAs and volts• On/Off, proportional, PI and PID controls• Automatic or manual temperature compensation• Parameters adjustable for custom applications• Two Set points and one alarm relay• Calibration with backup memory• Password protection against tampering• “Fail-safe” protection against power failure• Status LED on front panel• Self-diagnostics and troubleshooting guidesSPECIFICATIONS HI 700 HI 710RangeEC: 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm;0.0 to 199.9 mS/cm; Temperature: -10.0 to 100.0°CResolution EC: 0.1 μS; 1 μS; 0.01 mS; 0.1 mS; Temperature: 0.1 °CEC: 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9mS/cm; TDS: 0.0 to 100.0 ppm; 0 to 1000 ppm; 0.00 to 10.00 ppt; 0.0 to100.0 ppt; Temperature: -10.0 to 100.0°CEC: 0.1 μS; 1 μS; 0.01 mS; 0.1 mS; TDS: 0.1 ppm; 1 ppm;0.01 ppt; 0.1 ppt Temperature: 0.1 °C;Accuracy (@20°C/68°F)±0.5% F.S. (EC / TDS); ±0.5°C (0 to 70°C); ±1°C (outside)EC CalibrationAutomatic or manual at 1 pointTemperature CompensationAutomatic (with Pt100 probe) or manual from -10 to 100°C with ß = 0.00 to 10.00%/°CTDS Conversion Factor — Adjustable from 0.00 to 1.00OutputsAnalog: isolated 0-1 mA, 0-20 mA and 4-20 mA; 0-5 Vdc, 1-5 Vdc and 0-10 Vdc or digital: RS485 bi-directional opto-isolatedAnalog Input4-20 mASetpoint Relay2 contact outputs SPDT 5A-250 Vac, 5A-30 Vdc (resistive load)Alarm RelayPower SupplyEnvironmentDimensionsWeightContact output SPDT 5A-250 Vac, 5A-30 Vdc (resistive load)115 Vac ±10% or 230 Vac ±10%; 50/60 Hz0 to 50°C (32 to 122°F); RH max 95% non-condensingPanel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm1.6 kg (3.5 lb.)ORDERING INFORMATIONHI 700 and HI 710 is supplied with mounting brackets and instruction manual.Match the boxes in the product code to thecorresponding numbers according to desiredconfiguration.0, EC Controller1, EC/TDS Controller1, analog output2, RS485 outputACCESSORIESHI 504901 GSM supervisorHI 7030L 12880 μS/cm calibration solution, 500 mLHI 7031L 1413 μS/cm calibration solution, 500 mLHI 7033L 84 μS/cm calibration solution, 500 mLHI 7034L 80000 μ/cm calibration solution, 500 mLHI 7 022 -1, 115 VAC power supply2, 230 VAC power supply40HANNA instruments ®


Dosing pumpsChemical Metering PumpsBlackstone Series• Designed for all environments• Reliable• High quality material• Ideal for aquaculture applicationsThese simple and reliable chemical pumps are specially designed withPVDF and PTFE heads and diaphragms to resist damage from even themost corrosive chemicals.VersatilityBlackstone pumps have been designed to meet the ever changing needsof industry. To accommodate diverse applications, the pumps can be easilymounted anywhere in your plant with their broad, flat base and mountingholes for tank, shelf or floor mounting (horizontal). The rear of the pumphousing also provides mounting holes to facilitate vertical mounting: wall,tank or machine. With the pump valve assembly and unit controls bothlocated on the front of the pump, there is never a problem with installation orflow adjustments.Simple OperationBlackstone pumps are equipped with a single control for pump output. Theexternal Flow Rate Control (potentiometer) on the face of the pump allowsyou to adjust the percentage of flow from 0 to 100% of the pump's ratedcapacity. This feature eliminates the need to worry about stroke lengths andpower settings. An LED indicator lights up each time a stroke begins. Thisallows the user to assess the stroke rate from a distance.High Quality MaterialsBlackstone pumps have been manufactured with the highest level ofmechanical precision, from materials chosen for their inherent ability to resistthe effects of aggressive chemicals. When you select a Blackstone pump,you are eliminating the time consuming effort involved in picking the rightmaterial for your application.Blackstone pumps are supplied with the highest quality material as standardequipment, not optional. The diaphragm utilizes one-piece construction ofPTFE, which unlike conventional laminated diaphragms will stand up to thetest of time and wear. Ball valves are constructed in glass. The pumpheadand O-rings are all made of PVDF, PTFE and FPM/FKM which offerunsurpassed resistance.Rugged DesignBlackstone pumps are completely sealed during assembly and offer IP65protection against splashes and spills providing excellent protection evenin hostile environments. The fiber-reinforced polypropylene housing standsup to aggressive chemicals while offering superior strength under toughindustrial conditions.Part# Output Rated PressureWith Large DiaphragmsLPH GPH BAR PSI Strokes/minBL 20 18.3 4.8 0.5 7.3 120BL 15 15.2 4.0 1 14.5 120BL 10 10.8 2.9 3 43.5 120BL 7 7.6 2.0 3 43.5 120With Small DiaphragmsBL 5 5.0 1.3 7 101.5 120BL 3 2.9 0.8 8 116 120BL 1.5 1.5 0.4 13 188.5 120SPECIFICATIONSBL SeriesMax OutputSee table belowPump CasingFiber-reinforced polypropylenePumphead in PVDF, diaphragm in PTFE, glass ball valvesMaterialsand O-rings in FPM/FKM polyethylene 5 x 8 mm tubing and3/8" injection fittingSelf-primingMax height: 1.5 m (5 feet)Power Supply110/115 Vac or 220/240 Vac, 50/60HzMax Power ConsumptionApprox. 200 WProtectionIP65Environment0 to 50°C (32 to 122°F); RH max 95% non-condensingDimensions 165 x 194 x 121 mm (6.5 x 7.6 x 4.8’’)WeightApprox. 3 kg (6.6 lb.)ORDERING INFORMATION:BL 1.5-1 1.5 LPH flow rate, 110/115 Vac power supplyBL 1.5-2 1.5 LPH flow rate, 220/240 Vac power supplyBL 3-1 2.9 LPH flow rate, 110/115 Vac power supplyBL 3-2 2.9 LPH flow rate, 220/240 Vac power supplyBL 5-1 5.0 LPH flow rate, 110/115 Vac power supplyBL 5-2 5.0 LPH flow rate, 220/240 Vac power supplyBL 7-1 7.6 LPH flow rate, 110/115 Vac power supplyBL 7-2 7.6 LPH flow rate, 220/240 Vac power supplyBL 10-1 10.8 LPH flow rate, 110/115 Vac power supplyBL 10-2 10.8 LPH flow rate, 220/240 Vac power supplyBL 15-1 15.2 LPH flow rate, 110/115 Vac power supplyBL 15-2 15.2 LPH flow rate, 220/240 Vac power supplyBL 20-1 18.3 LPH flow rate, 110/115 Vac power supplyBL 20-2 18.3 LPH flow rate, 220/240 Vac power supplyACCESSORIES:HI 721101 Pumphead, O-ring and screwsHI 721102 Discharge valve assemblyHI 721103 Suction valve assemblyHI 721004* Injection valve assemblyHI 721005* Foot valve assemblyHI 721008 Ceramic weight (4 pcs.)* Required for operation(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com41


WarrantyWARRANTYLimited WarrantyHANNA instruments ® products are manufactured in our ISO 9001 facilities, meeting the highest quality standards in the industry. HANNA’s high standards also applyshould a product be returned due to defects in material or workmanship. Our extensive warranty extends up to five years on some products.Limitations: Warranted products may be returned for repair or replacement only at the discretion of HANNA instruments ® . In some circumstances, remedy mayconstitute refund for the price paid for the product.The warranty period commences from the original date of sale to the user or a maximum of 18 months from factory ship date. Warranty is valid only when the product is usedunder normal conditions and in accordance with operating limitations and prescribed maintenance procedures. The express warranty stated previously is the onlyexpress warranty given by HANNA to the end-user buyer. HANNA expressly disclaims any warranties implied by law, including but not limited to warranty ofmerchantability of fitness for a particular purpose. HANNA shall not be liable for any individual or consequential damages of any kind for breach of any warranty,negligence, on the basis of strict liability or otherwise. HANNA’s warranty periods are:5 years: HI 221, HI 222 & HI 2233 years: HI 901 & HI 902, HI 120, HI 110, HI 255, HI 250 series, pH 300 & HI 4200 series, Wine Line Photometers2 years: Benchtop Meters not mentioned previously, Portable Meters, Printing Meters, Stirrers & Industrial Meters, Waterproof Testers1 year: Dosing Pumps6 months: Testers & Pocket-size Thermometers, Electrodes & Probes—when used properly and according to prescribed procedures.Instrument Service:Warranty and non-warranty service, replacement, recalibration and repairs are performed by factory trained service technicians at HANNA’s Woonsocket, RI TechnicalService Center. All items must have a Return Goods Authorization (RGA) number that can be obtained by contacting the HANNA Technical Service Department. TheRGA number should be clearly marked on the outside of the box and the unit shipped prepaid and insured. Any product not bearing an RGAnumber will be refused. All products returned for warranty repair or replacement MUST be preceded or accompanied with proof of purchase, such as the original invoiceor packing slip. Under special circumstances it may be deemed necessary by HANNA instruments ® to issue a Return In Advance (RIA). In such cases, the defectivematerials must be returned to HANNA within 30 days. Materials not returned within 30 days become chargeable. Materials must be packed properly to avoid damageduring transport, which would render the warranty null and void. The sender is responsible for expediting any damage claims placed against the carrier.A flat minimum service charge of $60.00 (per hour) applies to non-warranty repairs or recalibration. Any materials returned for repair which are considerednon-warranty may be serviced at the previously stated hourly cost (excluding parts) following subsequent notification and approval of such.Product Return and ExchangeRETURNS/EXCHANGESReturning Merchandise:Should an instance occur when a product may need to be returned for exchange or credit, or should a discrepancy occur in a packing slip, HANNA instruments ® mustbe contacted to obtain a Return Goods Authorization Number (RGA). Please follow these steps:1. Within 30 days of receipt of merchandise call HANNA’s Technical Service Department to obtain a Return Goods Authorization Number.2. HANNA will issue a Return Goods Authorization Number.3. The number must be clearly marked on the outside of the package being returned. Shipments not bearing a Return Goods AuthorizationNumber will be refused.4. Credit returns may be subject to a 25% restocking fee.Terms and ConditionsReturn shipments must meet the following requirements to be accepted for credit:1. Products must be returned in the original packaging with labeling not defaced. All items returned will be inspected for credit worthiness.Credit will only be issued for product returned in like-new condition. No credit will be issued for product, which is not received inlike-new condition.2. All freight charges are the responsibility of the customer.3. All chemicals and reagents being returned must be packaged in accordance with U.S. Department of Transportation regulation. Only unopened chemicalsand reagents may be returned.HANNA instruments ® reserves the right to change or modify the design of its products at any time without advance notice.42HANNA instruments ®


NotesNOTES(888) 815-6422 • aquaculture@hannainst.comwww.hannainst.com43


For more information or for a distributor near you:(888) 815.6422aquaculture@hannainst.comAuthorized Distributorwww.hannainst.comP/L AQCAQR06 1.0 PRINTED IN USAHanna Instruments ® reserves the right to change or modify its products at any time without advance notice.


Albany's Amazing Aquarium1237 9th Street SEAlbany, OR 97321Tel: 541-926-3355Albanyaquarium@msn.comAquaculture Systems Technologies, LLC108 Industrial Ave.New Orleans, LA 70121Tel: (800) 939-3659504-837-5575Fax: 504-837-5585info@beadfilters.comwww.beadfilters.com/Aquaneering Inc.8280 Clairemont Mesa Blvd # 117San Diego, CA 92111Tel: 858-541-2028Fax: 858-541-2048info@aquaneering.comwww.aquaneering.comAquatic Eco-systems2395 Apopka BlvdApopka, FL 32703Toll Free: 877-347-4788Local: 407-886-3939Fax: 407-886-6787http://www.aquaticeco.com/Aquatic Network, LLC135 Auburn DriveCharlestown, RI 02813Tel: 401-364-6960Fax: 401-364-9757http://www.aquanet.com/aquastorejhac@aquanet.comParticipating Dealers


The Aquatic-Store1805 Scherer ParkwaySt. Charles, MO 63303Tel: 314-754-8715Fax: 707-221-0291orders@aquatic-store.comwww.water-testers.comAtlantic Aquaculture Supply560 Metacom AvenueWarren, RI 02885Tel: 800-442-8727Fax: 401-247-1116atlantic@atlanticaquaculture.comwww.atlanticaquaculture.com/Automated Aquarium Systems545 So. Pacific StreetTustin, CA 92780Tel: 714-669-1196Fax: 714-669-1196sales@automatedaquariums.comwww.automatedaquariums.com/Boatcycle, Inc.219 N. Van BurenHenderson, TX 75652Tel: 800-333-9154Fax: 903-657-4287support@boatcycle.comwww.boatcycle.comCustom Aquatic Life3915 Oceanic Dr #601Oceanside, CA 92056Tel: 800-397-7238Fax: 760-277-6760info@customaquatic.comwww.customaquatic.com


Divendi Americas Inc / Nutrishrimp, C.A.PO Box 565785Miami, FL 33256305-595-4619 Bus.305-468-6439 Faxwww.divendi.comwww.nutrishrimp.cominfo@divendi.comEvolution Laser Technology, LLC8906 Wall St, Ste 206Austin, TX 78754Tel: (512) 339-2201Fax: (512) 339-2632sales@evolutionLT.comwww.EvolutionLT.comH2O Instruments2380 Pawtucket AvenueEast Providence, RI 02914Tel: 401-438-8100Fax: 401-434-9526H2oinstruments@cs.comwww.h2oinstruments.com/H2O Science6616 N Alicia PlSioux Falls, SD 57104Fax: 605-367-1029nathanjenny@sio.midco.nethttp://search.ebay.com/_W0QQfgtpZ1QQfrppZ25QQsassZh2oQ2dscienceIntegrated Aqua Systems, Inc.PO Box 31816Bellingham, WA 98228Tel: 360-933-4353Fax: 360-933-4354info@integrated-aqua.comwww.integrated-aqua.com


J.L. Eagar Inc.526 North 700 WestP.O. Box 540North Salt Lake, UT 84054Tel: 801-292-9017Fax: 801-295-7569eagarinc@juno.comwww.eagarinc.com/Keeton Industries13751 N. County Road 11P.O. Box 249Wellington, CO 80549Tel: 970-568-7754Fax: 970-568-7795keeton@keetonaqua.comwww.keetonaqua.comMarine Biotech, Inc.54 West Dane Street, Unit ABeverly, MA 01915Tel: 978-927-8720Fax: 978-921-0231info@marinebiotech.comwww.marinebiotech.com/Pacific East Aquaculture, Inc.107 School StPO Box 217Mardela Springs, MD 21837Tel: 877-887-5224Fax: 410-219-3395drmac@dmv.comwww.pacificeastaquaculture.comPiece Of Reef816 Birch DrNorman, OK 73072Tel: 405 625 7891mrbelanger@sbcglobal.netwww.pieceofreef.com/


Premium Aquatics6050 Hanna Ave #4Indianapolis, IN. 46203Tel: 317-895-9005Fax: 317-895-9395sales@premiumaquatics.comwww.premiumaquatics.comPrilabsa International Corporation2970 West 84th Street, Bay #1Hialeah, FL 33018Tel: 305-822-8201Fax: 305-822-8211rribas@prilabsa.comwww.prilabsa.comProAquatica8847 Rose Hill DrOrlando, FL 32818Tel: 800-617-2686Fax: 407-522-9863www.proaquatica.comPure Solutions Unlimited, Inc. (PSI)2550 South Nova Rd #5South Daytona, FL 32119Tel: 888-833-8674Fax: (386) 322-4813purewater@clearwire.netwww.purelyh2o.comR & B Aquatic Distribution, Inc.P.O. Box 145Waring, TX 78074Tel: 800-259-9812Fax: 830-995-3922sales@rbaquatic.comwww.rbaquatic.com


Shark Aquarium Pet Center245 Route 22Hillside, NJ 07205Tel: 973-923-3200Fax: 973-923-3251info@sharkaquarium.comwww.sharkaquarium.comShrimp Feeder, Inc.8181 NW 36th Street # 16-AMiami, FL 33166Tel: 305-594-9889Fax: 305-463-7642info@foodforpet.comwww.shrimpfeeder.com/Standard Marine Supply Corp.120 North 20th St.Tampa, FL 33605Tel: 813-248-4905Fax: 813-247-4386johnkincaid@stanmartampa.comStoney Creek, Inc.4385 E 110th StGrant, MI 49327Tel: 800-448-3873Fax: 231-834-5537stoneycreek@ncats.netwww.stoneycreekequip.com