12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsc) Fan rotational 1500 rpm (max.) 750 rpm (max.)speedd) Air/ flue gas flow blade pitch control blade pitch controlcontrole) Fan critical speed not less than 125% <strong>of</strong>fan maximumoperating speed speedf) Fan componentdesign*g) Fan casingmaterial &thicknessh) Fan Housingdesign pressureto withstand torsionalstresses three (3)times the normal/ fullload motor torque atall speedsCarbon steel, 6.00mm (min.)Shut <strong>of</strong>f head <strong>of</strong> fan56not less than 125% <strong>of</strong>fan maximum operatingto withstand torsionalstresses three (3) timesthe normal/ full loadmotor torque at allspeedsAbrasion and wearresistant, high BHNsteel having minimum8.0 mm thickness or8mm mild steel withliner <strong>of</strong> thickness 10mm(min.)Shut <strong>of</strong>f head <strong>of</strong> fan* The ID fan components such as blades, hubs, casing etc. shall be chosento encounter the high dust burden <strong>of</strong> the order <strong>of</strong> 250 mg/Nm 3 . Theminimum wear life <strong>of</strong> ID fan components shall not be less than 25000hours <strong>of</strong> operation from the date <strong>of</strong> commissioning.ii) Silencers shall be provided at the suction <strong>of</strong> FD fans to limit the noiselevel as specified. FD fan suction shall be provided with rigid bird andtrash screen assembly and shall have suitable arrangement to avoidrainwater from directly entering the fan.iii) Fan Bearingsa) Bearing shall be provided with oil bath to prevent damage in case <strong>of</strong>complete loss <strong>of</strong> plant auxiliary power when the fans must coastdown without power.b) Oil reservoir in bearings housing shall be sized <strong>for</strong> maintaininglubrication <strong>for</strong> extended periods in case <strong>of</strong> oil circulation system isout <strong>of</strong> service.c) Duplex Pt-RTDs (100 ohm at 0 0 C) and temperature indicators shallbe provided <strong>for</strong> each bearing as per standard practice <strong>of</strong> the OEM <strong>for</strong>local as well as remote monitoring <strong>of</strong> bearing metal temperature.d) For mounting <strong>of</strong> vibration pads/ pickups, flat surfaces shall beprovided both in X and Y directions, on the bearing housing.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!