12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsf) All areas subject to lube oil or chemical spills will be provided withcurbs and drains.xv) Two main stairways shall be provided one on each side <strong>of</strong> the steamgenerator. One stairway shall extend continuously from grade to thehighest operating level and the other shall extend continuously fromgrade to the boiler ro<strong>of</strong>. Steel framing <strong>for</strong> penthouses <strong>for</strong> each stairwayshall be provided. The portion <strong>of</strong> main stairway within the enclosedportion <strong>of</strong> the building, if any, shall be designed <strong>for</strong> one hour smoke/ firepro<strong>of</strong> requirements.6.5.12 ElevatorsElevators shall be designed based on following criteria:i) Type <strong>of</strong> service One (1) no. passenger-elevator in TG hall andone (1) no passenger cum goods elevator inii) Design/ construction/installation codesboiler area per unit.a) Latest edition <strong>of</strong> IS: 14655 (all parts) andalso meeting any additional requirements <strong>of</strong>IS: 4666, IS: 1860 and IS: 3534.b) Any other equivalent codeiii) Load carrying capacity 1088 kg (equivalent to 16 person) <strong>for</strong>passenger elevator & 3000 kg <strong>for</strong> passengercum goods elevator.iv) Rated speed 0.55 m/sec <strong>for</strong> 3000 kg capacity elevator and1.0 m/sec <strong>for</strong> 1088 kg capacity elevator.v) Total travel As per steam generator supplier'srecommendations.vi) Number <strong>of</strong> floors to be Ten (minimum).servedvii) Entrances Twelve (12) (minimum) (all on same side).viii) Entrance and plat<strong>for</strong>msizeAs per design/ installation codes at (ii) above.ix) Elevator landings (min.) a) Ground floor.b) Mezzanine floor <strong>of</strong> TG hall.c) Main operating floor <strong>of</strong> TG hall.d) All burner plat<strong>for</strong>ms.e) Alternate soot blower levels.f) Coal gallery.g) Steam separator.h) At all regularly operating plat<strong>for</strong>ms.i) Laboratory floor.52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!