12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsb) Access openings alongwith air/ gas tight hinged doors shall beprovided <strong>for</strong> approach to above maintenance spaces without anyhindrance from hanger tubes.1. All access door shall be <strong>of</strong> 450mm x 450mm size (minimum).2. Access doors 800 mm above the nominal floor level shall haveaccess plat<strong>for</strong>m.3. Hanger tubes <strong>of</strong> horizontal banks shall have access opening <strong>for</strong>crossing over.c) Stainless steel erosion shields shall be provided <strong>for</strong> all bends <strong>of</strong>outermost tube/ coil <strong>of</strong> all SH/ RH sections and hanger tubes inareas where flue gas temperature is below FEGT. For the pendanttube sections, the erosion shield shall be provided on the leadingtubes and wherever else considered necessary as per the provendesign.d) Suitable arrangement <strong>for</strong> internal inspection <strong>of</strong> attemperators/headers shall be provided.vi) Headers and pipes, if made using X-20 Cr MO V 121 to DIN 17175material, shall have provisions to ensure that no site welding <strong>of</strong> thismaterial with similar or dissimilar material is needed.6.5.7 Economisersi) Economizer design shall con<strong>for</strong>m to the following criteria/requirementsunder all condition <strong>of</strong> operation and <strong>for</strong> the complete range <strong>of</strong> specifiedfuels.a) Economizer type Non-steaming type with parallel crossflow or counter flow arrangement.b) Approach temperature 17°C (minimum).within control rangec) Maximum average flue 10 m/sec (maximum localized velocitygas velocity through theeconomizer tube banks,across the cross-section not to exceed 12m/sec).with 25% excess air ateconomizer outlet. For high GCV low ash (say 10% andbelow) coals:12 m/sec (maximum localized velocityacross the cross-section not to exceed 14d) Economizer tubethicknessm/sec).i) Erosion allowance <strong>of</strong> 1mm (minimum)shall be provided in addition tothickness calculated as per IBR<strong>for</strong>mulae.42

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!