12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units6.3 Fuels6.3.1 Coali) The primary fuel <strong>for</strong> the Steam Generator(s) shall be coal (coalcharacteristics <strong>of</strong> design coal, worst coal, best coal and range <strong>of</strong> coal <strong>for</strong>the project to be considered <strong>for</strong> boiler design).ii) The Steam Generator shall be designed to give the guaranteed efficiencywhen firing the coal having the characteristics <strong>for</strong> design coal.iii) The Steam Generator and its auxiliaries shall also be capable <strong>of</strong> obtainingthe boiler maximum continuous rating (BMCR) when firing the coalhaving the characteristics <strong>for</strong> worst coal. The Steam Generator and itsauxiliaries shall be designed <strong>for</strong> efficient and trouble free operation whenfiring the design, worst and best coals and any <strong>of</strong> the coals characteristicsin between these <strong>for</strong> complete load range. The Steam Generator and itsauxiliaries shall also be capable <strong>of</strong> giving BMCR rating and meet otheroperating capabilities, without any trouble and limitations, when firing thecoals having the specified range <strong>of</strong> characteristics.iv) Steam Generator and its auxiliaries shall also be capable <strong>of</strong> obtainingmaximum continuous rating when firing with any <strong>of</strong> the coal within thespecified range <strong>of</strong> coal. <strong>System</strong> redundancies/ margins on equipment/auxiliary sizing need not be available under such fuel firing conditionunless specifically mentioned otherwise. However, equipments/ systemsshall not exceed their safety limits under such firing, and shall nottransgress into factors <strong>of</strong> safety as per specification/ codes.6.3.2 Fuel oilThe fuel oil (HPS/LSHS/HFO) shall be used <strong>for</strong> start-up, coal flamestabilization and low load operation <strong>of</strong> the Steam Generator(s). In addition,the light diesel oil (LDO) firing facilities shall also be provided <strong>for</strong> cold startup <strong>of</strong> the steam generator(s). Alternatively, only LDO can be used <strong>for</strong> startup,coal flame stabilization and low load operation including cold start-up.6.4 Salient Design <strong>Features</strong> and Capabilities6.4.1 Limiting parameters <strong>for</strong> steam generator designThe Steam Generator design shall comply with the following limitingparameters with 'design coal' firing, under stipulated ambient air condition i.e.27 0 C temperature and 60 % relative humidity:i) Excess air at economizer outletat 100% TMCR loadii) Corrected flue gas temperature(at 100% TMCR load)20% (minimum).125 o C or as predicted by the supplier atair preheater outlet (also consideringacid dew point) whichever is higher.25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!