12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsa) Test loads 100% TMCR and 80% TMCR.b) Test conditions Boiler operating at rated steam parameter, excessair, coal fineness and firing design coal.c) Ambientconditions27 o C dry bulb temperature and 60% relativehumidity. The reference air temperature <strong>for</strong> theefficiency guarantee/ testing shall be taken as27 o C at APH inlet (without consideration <strong>of</strong> heatcredits).d) No. <strong>of</strong> readings Two sets <strong>of</strong> consistent readings <strong>for</strong> each <strong>of</strong> testloads. Average <strong>of</strong> the test efficiencies based onabove two readings <strong>for</strong> each load shall beconsidered <strong>for</strong> evaluation.e) APH leakages to Guaranteed or actual whichever is higher.be consideredf) Test duration Four hours. No soot blowing shall be allowedduring the test period or during stabilizationperiod <strong>of</strong> four hours prior to commencement <strong>of</strong>the test.g) Heat credits No heat credits allowed. The guaranteed steamgenerator efficiency shall be without any heatcredit.ii)The guaranteed efficiency shall comply with following limitingparameters with design coal firing:a) Excess air at economizer outlet at100% TMCR loadb) Corrected flue gas temperature(at 100% TMCR load)c) Boiler efficiency loss to beconsidered due to unburnt carbon20% (minimum).125 0 C or as predicted by thesupplier at air preheater outletwhichever is higher.Minimum 1%.iii)The following correction curves shall be applicable <strong>for</strong> per<strong>for</strong>mance test<strong>of</strong> the steam generator:a) Ambient air temperature.b) Relative humidity <strong>of</strong> ambient air.c) Hydrogen in coal.d) Moisture in coal.e) Gross calorific value <strong>of</strong> coal.f) Feed water temperature at economiser inlet.5.5.2 Per<strong>for</strong>mance test <strong>of</strong> ESPi) The per<strong>for</strong>mance/ acceptance tests shall be carried out in accordancewith method-17 <strong>of</strong> EPA (Environmental Protection Agency <strong>of</strong> USA)code.21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!