12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units5.4.12 Furnace exit gas temperature (FEGT)It shall be demonstrated that maximum furnace exit gas temperature (FEGT)shall be minimum 60 deg C below the minimum initial de<strong>for</strong>mationtemperature (IDT) <strong>of</strong> ash. A comprehensive thermal per<strong>for</strong>mance test (TPT)shall be conducted <strong>for</strong> this purpose on one unit. FEGT shall be demonstratedthrough such TPT by indirect measurement.5.4.13 Air heater air in leakageIt shall be demonstrated that the air-heater air-in-leakage after 3000 hours <strong>of</strong>steam generator operation does not exceed the specified/ quoted values.5.4.14 Equipment cooling water systemi) Inlet and outlet temperatures on the primary and secondary side <strong>of</strong> theplate type heat exchangers as per design shall be demonstrated at site.ii)Pressure drop across plate type heat exchanger on primary and secondaryside cooling water circuits shall be demonstrated at site.iii) Satisfactory operation <strong>of</strong> primary side DMCCW pumps and secondaryside cooling water pumps (as applicable) without undue noise andvibration while operating in isolation or in parallel with other pumpsshall be demonstrated at site.5.4.15 Generator excitation systemThe per<strong>for</strong>mance <strong>of</strong> generator excitation system as specified shall bedemonstrated.5.4.16 Steam condensing planti) The value <strong>of</strong> design condenser pressure, to be measured at 300 mmabove the top row <strong>of</strong> condenser tubes, shall be demonstrated under VWOcondition, 1% make-up, design CW inlet temp. and CW flow. Thecondenser vacuum shall be measured with a vacuum grid utilizingASME basket tips.ii)Temperature <strong>of</strong> condensate, at outlet <strong>of</strong> condenser, shall be demonstratedto be near to saturation temperature corresponding to the condenserpressure at all loads.iii) Oxygen content in condensate at hotwell outlet shall not exceed 0.015cc/litre over 50-100% load range and shall be determined according tocalorimetric Indigo-Carmine method.iv)Air leakage in the condenser under full load condition shall not exceedmore than 50% <strong>of</strong> design value taken <strong>for</strong> sizing the condenser airevacuation system.17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!