12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsd) 2x100% capacity DM water pumps shall be provided <strong>for</strong> watersupply <strong>for</strong> chemical preparation/dosing and transfer <strong>of</strong> resin fromservice vessel to regenerating vessels and vice versa. The pumpsshall be horizontal centrifugal type and con<strong>for</strong>m to IS: 1520/IS: 5120or equivalent without any negative tolerance. All wetted parts <strong>of</strong> thepump shall be <strong>of</strong> CF-8M.ii)Vessel Free BoardThe pressure vessels in the common external regeneration facility shallbe provided with adequate freeboards over the top <strong>of</strong> the settled resins, tominimize resin loss during regeneration. Minimum freeboards to beprovided shall be as below:a) Mixed resin Storage vessel : 50%b) Resin separation vessel : 75%c) Cation regeneration vessel : 75%d) Anion regeneration vessel : 75%iii)Chemical Dosing <strong>System</strong>a) 2x100% capacity hydraulically operated ejectors or metering pumpsshall be provided each <strong>for</strong> dosing <strong>of</strong> acid and alkali. Material <strong>of</strong>construction shall be suitable <strong>for</strong> liquid being handled.b) Acid ejectors/ metering pumps shall take suction from 2x100% acidmeasuring tanks and alkali ejectors/ metering pumps from 2x100%alkali day tanks. The capacity <strong>of</strong> tanks shall be atleast 20% higherthan that required from process calculations.c) For heating <strong>of</strong> alkali diluent water, 2x50% electrical heating coil in aMSRL tank shall be provided. The capacity <strong>of</strong> tank shall beminimum 20% higher than the maximum water demand. The heatersshall be sized <strong>for</strong> heating the water from 15 0 C to 45 0 C within a timeperiod not more than 5 hours.d) Complete system <strong>for</strong> <strong>of</strong>f-stream ammoniation <strong>of</strong> the resins, usingammonium hydroxide, shall be provided, if felt necessary, to meetthe system requirements.iv)Bulk Acid and Alkali Storage Tanks and Unloading Pumpsa) The bulk acid & alkali storage tanks shall be horizontal, dished ends,cylindrical type as per BS EN 12285 or equivalent standard. Thesetanks shall be <strong>of</strong> mild steel construction with inside surface rubberlined to 4.5 mm thickness in three layers.198

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!