12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units21.1 GeneralCHAPTER- 21EQUIPMENT COOLING WATER (ECW) SYSTEMClosed circuit type ECW system shall be provided with demineralised (DM)water in the primary circuit and water tapped <strong>of</strong>f from CW system upstream <strong>of</strong>condenser in the secondary circuit. ECW system shall be provided unit-wiseand shall cater to cooling water requirements <strong>of</strong> TG and its auxiliaries as wellas Steam Generator auxiliaries. Primary cooling circuits <strong>for</strong> auxiliaries <strong>of</strong> TGand SG packages shall be independent. The secondary cooling water circuitshall, however, be common <strong>for</strong> both the primary cooling systems.21.2 <strong>System</strong> Requirements21.2.1 For primary circuit <strong>of</strong> TG auxiliaries <strong>of</strong> each unit, a set <strong>of</strong> demineralisedcooling water (DMCW) pumps <strong>of</strong> 3x50% capacity shall discharge the coolingwater through 3x50% capacity plate heat exchangers (PHE). For SGauxiliaries <strong>of</strong> each unit, 2x100% capacity DMCW pumps and 2x100 %capacity plate heat exchangers shall be provided.21.2.2 The outlet header from plate heat exchangers shall be suitably branched <strong>of</strong>f tosupply the cooling water to the various auxiliary coolers. Outlet from theauxiliary coolers shall be connected back into a common return header and ledback to the suction <strong>of</strong> DMCW pumps to complete the closed loop primarycooling circuit.21.2.3 For both the primary cooling circuits <strong>of</strong> each unit, an overhead tank <strong>of</strong>minimum effective capacity <strong>of</strong> 10 m 3 corresponds to 60% <strong>of</strong> the tank heightshall be provided with level control facility. The overhead tank shall serve thefollowing:i) For normal make-up to closed loop cycles.ii)iii)iv)To meet expansion <strong>of</strong> closed cycle water due to temperature fluctuationsand to control other transients.For adequate Net Positive Suction Head (NPSH) <strong>for</strong> DMCW pumps.Emergency water supply to critical coolers in case <strong>of</strong> power failure.21.2.4 The pH <strong>of</strong> DM water in the closed loops shall be continuously monitored andcontrolled at around 9.5. The pH shall be controlled by dosing sodiumhydroxide or ammonia in DM water overhead tank and primary side piping <strong>for</strong>TG and SG auxiliaries.189

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!