12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units19.1 PurposeCHAPTER - 19STEAM TURBINE HP-LP BYPASS SYSTEMThe HP and LP turbine bypass system is envisaged to be used <strong>for</strong> thefollowing functions:i) To enable boiler and turbine to be operated independent <strong>of</strong> each otherduring start-up and shutdown.ii) To enable in quick reloading <strong>of</strong> the unit following a turbine trip.iii) To quickly open to relieve the system from high steam pressure in theevent <strong>of</strong> generator breaker opening/ turbine tripping as well as duringlarge load throw-<strong>of</strong>f.iv) To reduce starting and loading time <strong>of</strong> steam generator.v) For house load operations.19.2 General Requirements19.2.1 A HP bypass system shall be provided between MS and CRH and shall haveaggregate capacity not less than 60% <strong>of</strong> the main steam flow at BMCRcondition considering main steam parameters at the upstream <strong>of</strong> valves &CRH steam parameters corresponding to 60% TMCR condition on thedownstream side. The HP bypass system shall have minimum 2x50%capacity valves. In addition the aggregate capacity <strong>of</strong> HP Bypass valves shallbe adequate to evacuate the required minimum steam flow from the boilerunder various start- up conditions (viz. cold/ warm/ hot start ups).19.2.2 LP bypass shall be provided between HRH and condenser and shall bedesigned to condition the incoming steam from re-heater corresponding toparameters resulting from operation <strong>of</strong> HP bypass as stated above, toparameters matching with those <strong>of</strong> LP Turbine exhaust steam. The valvecapacity shall be commensurate with that <strong>of</strong> HP bypass system plus the spraywater used in HP bypass. Number <strong>of</strong> LP Bypass valves shall be as permanufacturer’s standard practice subjected to a minimum <strong>of</strong> two (2)numbers.19.2.3 Seat tightness <strong>of</strong> the HP and LP bypass valves shall be equivalent to leakageClass V con<strong>for</strong>ming to ANSI/FCI 70-2.19.2.4 HP bypass station spray water requirement shall be provided from Boilerfeed pumps discharge & LP bypass spray water requirement shall beprovided from condensate extraction pump discharge.185

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!