12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsii)Flame monitoring system shall be fail safe and easily maintainablewhich shall include flame detectors <strong>of</strong> proven design <strong>for</strong> the type <strong>of</strong>fuel, environmental condition and other conditions, <strong>of</strong> establishedreliability at all loads <strong>of</strong> the steam generator. It shall be designed towork under all adverse conditions such as wide variation in fuel/airinput ratio, wide variation in fuel characteristics, variation in operatingtemperature, maximum temperature under interruption <strong>of</strong> cooling airsupply. The system shall con<strong>for</strong>m to NFPA recommendation andlocation <strong>of</strong> detectors as per NEC requirements.iii) Flame detectors shall be working on the dynamic and static properties<strong>of</strong> primary combustion zone <strong>of</strong> each type <strong>of</strong> fuel and flicker frequency<strong>of</strong> flame. It shall pick up only the flame to which it is assigned andshall not respond to the adjacent and background flame or otherradiations generated in the furnace. The design shall also take intoaccount the absorption by a coal shroud, recirculated dust or otherdeposition on the flame detector head. The complete system shallprovide the discrimination between oil and coal flame. Intensityindicators <strong>for</strong> main flame shall be provided alongwith galvanicallyisolated 4-20 mA DC signals and hooked to SG DDCMIS.iv)The system shall be easily maintainable and include automatic self testfacility at regular interval.v) A portable flame detector testing kit shall be provided with built instabiliser, capable <strong>of</strong> simulating both oil and coal flame, and testing <strong>of</strong>flame detector head unit at field. The testing kit shall also have facility<strong>for</strong> testing all type <strong>of</strong> electronic cards as being used in the flamemonitoring system.vi) In case <strong>of</strong> tangentially fired boiler, the flame detectors shall bearranged in such a manner that coal flame detectors are available <strong>for</strong>each coal burner <strong>of</strong> both above and below each coal burner andseparate oil flame detectors shall be provided <strong>for</strong> each oil burner. Incase <strong>of</strong> discriminating type flame detectors capable <strong>of</strong> detecting anddiscriminating both oil and coal flame, with the help <strong>of</strong> a singlescanner, the same can also be utilised <strong>for</strong> monitoring both oil and coalflame. For any other type <strong>of</strong> firing i.e. non-tangential type the flamedetectors shall be provided <strong>for</strong> each coal and oil burner respondingonly to the flame <strong>of</strong> its associated burner.vii) 2x100% scanner air fans, one AC operated and other DC operated,shall be provided to supply cooling air <strong>for</strong> the flame detectors.17.3.2 Coal feeders control and instrumentationi) Coal feeders shall be provided with microprocessor based C&I systempreferably using same family <strong>of</strong> hardware as that <strong>of</strong> DDCMIS.162

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!