12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsc) Data transmitting speed shall be sufficient to meet the responses <strong>of</strong>the system in terms <strong>of</strong> displays, control etc. under worst possibledata loading condition and minimum 20% spare capacity shall beavailable <strong>for</strong> future expansion.d) UTP cables or coaxial cables or fibre optic cables shall be employed<strong>for</strong> system bus.e) In case <strong>of</strong> any distance or other limitation, provision <strong>of</strong> suitablerepeaters, MODEMS, amplifiers, special type <strong>of</strong> cables like opticalfibres etc., as required, shall be made to make the DCS fullyoperational.ii)Station LANThe servers/ ethernet LAN <strong>of</strong> the each unit shall be connected to astation wide ethernet Local Area Network (LAN). The PCs at variousplant locations and PLC/PC based systems shall be connected to thisstation wide ethernet LAN through TCP/IP protocol. The stationhead/O&M head & shift in-charge shall be located in this LAN tomonitor data <strong>of</strong> all units as well as <strong>of</strong> the common plants and <strong>of</strong>f-siteplants.A server shall be provided <strong>for</strong> this station wide LAN. All networkingfunctions <strong>of</strong> LAN, calculation including merit order calculation shall beper<strong>for</strong>med in this server.17.2.10 Sequence <strong>of</strong> events (SOE) recording systemi) The DDCMIS shall be provided with sequence <strong>of</strong> events (SOE)recording system capable to scan and record events in the sequence <strong>of</strong>occurrence within a resolution <strong>of</strong> one (1) millisecond. That is, all SOEpoints entering status change shall be reported and time tagged within1 (one) millisecond <strong>of</strong> their occurrence. Input card shall be equippedwith digital filters with filter delay <strong>of</strong> minimum 4ms (identical <strong>for</strong> allpoints) to eliminate contact bounce such that field contact which ischanging state must remain in the new state <strong>for</strong> successive 4 ms to bereported as one event. The start <strong>of</strong> data collection <strong>for</strong> SOE report shallbe reported to OWS within 1 sec <strong>of</strong> SOE data collection initiation. Thesystem shall also have provision <strong>of</strong> rejection <strong>of</strong> chattering inputs.ii)The system shall also include provision <strong>for</strong> historical storage andretrieval <strong>of</strong> SOE reports <strong>for</strong> 3 months period.iii) The SOE report collection shall begin on occurrence <strong>of</strong> change <strong>of</strong>status <strong>of</strong> any SOE point and shall be printed after an operatorselectable time interval <strong>of</strong> 1 to 3 min. or 100 status changes have takenplace after the first event. Adequate memory to accommodate 6 (six)SOE reports i.e., two buffers <strong>of</strong> 100 status changes each shall beprovided. Seventh SOE report shall overlap the first SOE reportmemory and so on.160

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!