12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsvice versa without resulting in any change in control status. In case <strong>of</strong>switchover from main controller to the 100% hot backup controller, theback-up controller shall work as the main controller.Facility shall also be provided <strong>for</strong> manual switchover from main to 100%hot back-up controller and vice versa from the programmer's console.17.2.4 Binary controls/open loop control system (OLCS) functioni) The OLCS shall include sequence control, interlock & protection <strong>for</strong>various plant auxiliaries, valves, dampers, drives etc. The sequencecontrol shall provide safe and automatic startup and shutdown <strong>of</strong> plantand <strong>of</strong> plant items associated with a plant group. The interlock andprotection system shall ensure safe operation <strong>of</strong> plant/plant items at alltimes and shall automatically shut down plant/plant items when unsafeconditions arise.ii) The OLCS shall be arranged in the hierarchical control structureconsisting <strong>of</strong> group level, subgroup level & drive level (as applicable).It shall be possible to per<strong>for</strong>m automatic unit startup & shutdown byissuing minimum number <strong>of</strong> command from the OWS.The group level shall control a set <strong>of</strong> functional sub-groups <strong>of</strong> drives.Appropriate start-up and shut down commands shall be issued to the subgroupcontrol and various checkbacks shall be received from sub-groupsor drives. Each sub-group shall execute the sequential start-up and shutdown programmes <strong>of</strong> a set <strong>of</strong> inter-related drives along with systeminterlocks and protections associated with that sub-group as well as basicinterlocks and protections related to individual drive falling under thatsub-group. The drive level shall accept commands from the sub-groups,push buttons (wherever provided), etc., and transmit them to therespective drive, after taking into account various interlocks andprotections and the safety <strong>of</strong> that particular drive.iii)iv)A sequence shall be used to move a set <strong>of</strong> groups and sub-groups froman initial steady state (<strong>for</strong> instance 'OFF') to a final steady state (<strong>for</strong>instance 'ON'). The sequence initiating command <strong>for</strong> the unit and grouplevel shall be issued from TFT/KBD.Manual intervention shall be possible at any stage <strong>of</strong> operation and thesequence control shall be able to continue at the correct point in theprogramme on return to automatic control. Protection commands shallhave priority over manual commands, and manual commands shallprevail over auto commands.v) Open or close priority shall be selectable <strong>for</strong> each drive.143

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!