12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsc) Margin Each excitation system channel shall bedesigned to continuously carry at least 110%<strong>of</strong> the rated machine excitation current at therated output <strong>of</strong> the machine and highercurrents <strong>for</strong> short time duty. Short time dutyas mentioned above shall be on MCR base asper clause 1.14 <strong>of</strong> part III in VDE 530.d) Excitation systemresponse timee) Excitation responserati<strong>of</strong>) Excitation systemceiling voltage2>1.5 times rated load excitation voltage.g) Field <strong>for</strong>cing capability Each excitation system channel shall becapable <strong>of</strong> supplying without damage to any<strong>of</strong> the components, the field <strong>for</strong>cing voltageand current <strong>of</strong> the system <strong>for</strong> a period <strong>of</strong> 10seconds without exceeding the limits <strong>of</strong>temperature <strong>for</strong> rectifier junction and sink,when the equipment starts at normal operatingtemperature.iii) Automatic voltage regulator (AVR)a) Voltage regulator The excitation system shall be designed insuch a manner that due to any single fault inAVR firing circuit pulse trans<strong>for</strong>mer,rectifying elements in any channel etc.excitation system shall be available with itsfull capacity. All rectifying elements shallhave over voltage and short circuit protection.b) Number <strong>of</strong> channels Two numbers fully equipped automaticchannels having independent inputs andautomatic changeover shall be provided.Either channel shall be capable <strong>of</strong> being themain or standby. Either channel shall becapable <strong>of</strong> being selected as manual also.c) Characteristics1. Auto control range (±)10% <strong>of</strong> rated terminal voltage in all modes<strong>for</strong> voltage level adjustments <strong>of</strong> generatoroperation.2. Frequency range <strong>of</strong> 47.5Hz to 51.5Hz.operation3. Accuracy at whichgenerator voltage tobe heldBetter than 0.5% <strong>of</strong> the set value over thewhole load range <strong>of</strong> the generator.133

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!