12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Unitsiv) Dryer typeReactivation/ Refrigeration/ Manufacturer’spractice.v) Valve inter-locking 3-way valve used along with the drier <strong>for</strong>interconnecting the H 2 and air line (asapplicable) preferably have mechanical interlocking,such that closing <strong>of</strong> the H 2 side portis positively ensured be<strong>for</strong>e opening <strong>of</strong> the airside port.vi) On-line dew pointmeasurementvii) Gas analyserviii) Portable gas analyzerTo be provided across the inlet and outletlines to the drying system.To be provided with thermal conductivity/ gasdensity based type to continuously analyzethe gas discharged from the casing duringpurging and also analyze samples <strong>of</strong> thecasing H 2 during normal operation.The analyzer to measure the gas purity underthe following three conditions :a) Normal percentage <strong>of</strong> purity <strong>of</strong> H 2 in air inthe generator casing. Purity range toinclude a low purity alarm.b) Percentage <strong>of</strong> H 2 in CO 2 leaving the casingwhen H 2 is being admitted or expelled.c) Percentage <strong>of</strong> air in CO 2 leaving the casingwhen CO 2 is being admitted or expelled.Similar as detailed above under clause "GasAnalyzer" to be provided <strong>for</strong> supervision <strong>of</strong>the gas purging operation.16.2.2 Seal oil systemi) General A complete seal oil supply and control systemincluding AC and DC motor operated pumpsets, coolers, etc.ii) Number <strong>of</strong> pumps 2x100% AC motor driven pumps. 1 no. 100%DC motor driven pump.iii) Emergency conditionDuring short time emergency, which mayarise due to non-availability <strong>of</strong> both AC andDC pumps, unit may be tripped and seal oilsupply <strong>for</strong> such coasting down period shall befrom a suitable arrangement from lubricationoil system or a damper tank or as permanufacturer’s proven practice.130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!