<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units14.5.6 The temperature in the flash tanks shall be maintained by using condensatespray or service water spray (<strong>for</strong> flash tanks open to atmosphere). The sprayshall be automatically controlled. However, <strong>for</strong> flash tanks open toatmosphere continuous spray through an orifice shall also be acceptable.14.5.7 Facility shall be provided <strong>for</strong> remote manual operation <strong>of</strong> the drain valvesfrom the control room. Motor operated drain valves shall be interlocked toopen/ close as per the process requirements. Position indication <strong>of</strong> drainvalves shall be provided in the control room.112