12.07.2015 Views

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

Standard Technical Features of BTG System for Supercritical 660 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Standard</strong> <strong>Technical</strong> <strong>Features</strong> <strong>of</strong> <strong>BTG</strong> <strong>System</strong> <strong>for</strong> <strong>Supercritical</strong> <strong>660</strong>/800 MW Thermal Units13.2.3 Design parameters <strong>for</strong> condenser and associated systemsi) Condenser Design Parametersa) Number <strong>of</strong> pressure stages Single pressure/ dualpressureb) Number <strong>of</strong> passes Single pass/ double passc) Number <strong>of</strong> shells One/ twod) Design cold water temp 33 0 C 5e) Water velocity in the tubes 1.6 to 2.2 m/sf) Maximum design condenser pressure 77 mm Hg (abs) 6g) Max. tube length between tube plates 15 m (indicative)h) Temperature rise <strong>of</strong> circulating water 9 to 11 deg C 7across the condenseri) Cleanliness factor 0.9j) Fouling factors As per HEIk) Tube plug margin 5% under designconditionii)l) Max. CW side pressure drop acrosscondenser and associated piping systemat design flow with tube cleaning systemin operation5 mwc <strong>for</strong> singlepressure condenser &9 mwc <strong>for</strong> dual pressurecondenserm) Maximum/minimum temperature <strong>of</strong> 36 deg C 8 /15 deg Ccirculating watern) Condenser arrangement Perpendicular to TGaxiso) Water box design pressure 5.0 kg/cm 2 (g) and 0.1kg/cm 2 (abs)p) Water box test pressure 1.3 times the designpressure (minimum)q) Water box design temperature 60 0 Cr) Shell side design pressure Full vacuum and 1.08kg/cm 2 (g)s) Shell side design temperature 120 0 CDesign Parameters <strong>for</strong> Isolating Butterfly Valves, Expansion Jointsand CW Piping etc.a) Design pressure 5 kg/ cm 2 (g) and 0.1kg/cm 2 (abs)b) Design temperature 60 0 Cc) Test pressure 1.3 times the designpressure (minimum)5 30 00 C <strong>for</strong> sea water based once- through type CW system6 60mm Hg (abs) <strong>for</strong> sea water based once- through type CW system7 Not to exceed 7 0 C <strong>for</strong> sea water based once- through type CW system8 33 0 C <strong>for</strong> sea water based once- through type CW system101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!