12.07.2015 Views

CAT#258R3-FLP X96A.cdr - Imimg

CAT#258R3-FLP X96A.cdr - Imimg

CAT#258R3-FLP X96A.cdr - Imimg

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PROGRAMMABLE ONOFF CONTROLLERFLAMEPROOF, IP65<strong>X96A</strong>• Two universal inputs• 0 / 1 / 2 / 3 / 4 setpoints corresponding toinput 1, input 2• Isolated 2 x 0/4~20 mA or 0-10 V DCretransmission outputs corresponding toinput 1, input 2• 24 V DC transmitter supply• RS485 / MODBUS RTU• 85~265 V AC SMPS• ONOFF controlSPECIFICATIONSAll specifications at ambient of 25 C, unless specified otherwise<strong>CAT#258R3</strong>/P1/2/300911/AINPUTSNo. of inputs 2 (input 1, input 2)Input group 1(common for both inputs)Thermocouple B, E, J, K, N, R, S, TRTDPt100, 3-wireVoltage0~50 mVCurrent0~20 mA, 4~20 mAInput group 2(common for both inputs)Thermocouple B, C, D, E, G, J, K, N, R, S, TRTDPt100, 3-wire, Cu53Current0~20 mA, 4~20 mA,Square root (for input 1)Voltage0~50 mVThrough DIP selection followingvoltage inputs are available :0~1 V, 0~5 V, 0~10 V, 0~10 mV,0~100 mV, 0~200 mVTransmitter supply22 V nominal, 30 mA maxRange limits See Table 1Accuracy See Table 1Cold junction compensation AutomaticSensor break protection User programmableINDICATIONProcess variable Upper : 4 digit, 7 segment0.56” (14.2 mm) red LED displaySetpoint Lower : 4 digit, 7 segment0.56” (14.2 mm) green LED displayStatus indicationLEDs for relay statusLEDs for setpoint indicationLEDs for communicationOUTPUTSNo. of relays 0 / 1 / 2 / 3 / 4Relay contact typeNO-C-NCRelay contact rating5A / 230V AC, resistiveSSR drive12 V DC drive signal forexternal SSRNo. of analog outputs0 / 1 / 2 (current or voltage)Current output 4~20 mA / 0~20 mA / 20~4 mA /20~0 mA isolated from inputMaximum load for current 500 ohmsoutputVoltage output0~10 V / user specifiedLoad for voltage output >10 KohmsCOMMUNICATIONPortRS485ProtocolModbus RTUSlave ID User programmable (1~256)ENCLOSUREEnclosureMaterialDimensions (in mm)ProtectionKeyboardMountingMounting accessoriesCable entries** Cable glands to beordered separatelyPROGRAMMABLEPARAMETERSSetpoint Full range (See Table 1)Unit°C, °F, EUResolutionUser selectable0.01, 0.1 or 1 for linear input,0.1 or 1 for temperatureHigh scale Full range (See Table 1)Low scale Full range (See Table 1)Digital filterA (minimum) ~ F (maximum)Hysteresis0~25% spanBias (for process variable) -50 to 50% of range limitRelay logica. Heatb. Coolc. Fullscale high alarmd. Full scale low alarme. Deviation high alarmf. Deviation low alarmg. Inband alarmh. Outband alarm(e. to h. available for SP2, SP3,SP4 only)Alarm typesSelf reset or latched and can bedisabled at power onAlarm acknowledgeFront panel function used toreset relay in alarm conditionSetpoint lockON, OFFLevel lockON, OFFRelay actionReverse / directOTHERSupply voltageCertified flameproof forgas groups I, IIA & IIBAluminium alloy352(H) x 190(W) x 170(D)IP654 PushbuttonsWall mountIncluded5 x 3/4” ETa) 85~265 V AC, 50/60 Hzb) 20~35 V DC (optional)4 watts maximumPower consumptionOperating ambienttemperature 0~50 °CRelative humidityBelow 90%, non condensingwww.radix.co.in/flp.htm


PROGRAMMABLE ONOFF CONTROLLERFLAMEPROOF, IP65<strong>X96A</strong>TABLE 1SENSOR / INPUTInput Group 1Pt - 6% Rh / Pt - 30% Rh (B)Chromel / Constantan (E)Iron / Constantan (J)Chromel / Alumel (K)Nicrosil / Nisil (N)Pt / Pt - 13% Rh (R)Pt / Pt - 10% Rh (S)Copper / Constantan (T)Tungsten - 5% Rh / Tungsten - 26% Rh (C)Tungsten - 3% Rh / Tungsten - 25% Rh (D)Tungsten / Tungsten - 26% Rh (G)Cu53 0 180 0 180 ± 0.3 ± 0.5Linear (0~10 mV, 0~100 mV, 0~200 mV,0~1 V, 0~5 V, 0~10 V)400-270-210-270-27000-27000018208507601372130017601760400Pt100, 3-wire -200 850 -200 600 ± 0.3 ± 1.0Linear (0~50 mV, 0~20 mA, 4~20 mA) -1999 9999 -1999 9999± 5 EU ± 20 EUInput Group 2RANGE LIMITS(°C / EU)LOW SCALE HIGH SCALE232023102310RANGE IN WHICHACCURACY IS SPECIFIEDLOW SCALE HIGH SCALE-1999 9999 -1999 9999± 5 EU ± 20 EULinear (4~20 mA) with square root 0 9999 0 9999 ± 10 EU ± 40 EU40000-50-50400400-200The following inputs are available in Input Group 2 in addition to inputs of Input Group 1.ORDERING INFORMATION<strong>FLP</strong> <strong>X96A</strong> will be supplied with the followingstandard specifications :00018208507601200120017601760400232023102310TYPICAL ACCURACYAT 30 °C(°C / EU)± 3± 1± 1± 1± 1± 2± 2± 1± 3± 3± 3WORST CASEACCURACY(°C / EU)± 5± 3± 3± 3± 3± 5± 5± 3± 5± 5± 51.2.3.Input Input group 1Supply voltage 85~265 VACRS485Not providedORDER CODE2194AA0102030405060708ConfigurationNo. of inputs Relay4~20 mAoutput1 2 01 2 11401221422 00222400Ordering OptionsThe following ordering options are available on request.Minimum order quantity and/or minimum order value may apply.1.2.3.4.OptionAnalog outputSupply voltageInputCommunicationDetails0~10 V DC24 V DCInput group 2RS485AN ISO 9001:2008 COMPANYINSTRUMENTS T : + 91 22 42537777 x 701 F : + 91 22 42537700 E : sales@radix.co.inSENSORS T : + 91 22 42537777 x 732 F : + 91 22 42537700 E : sensors@radix.co.inGAUGES T : + 91 22 42537777 x 733 F : + 91 22 42537700 E : gauges@radix.co.inAUTOMATION C : 0-9322405471 C : 0-9324319150 E : automation@radix.co.inRadix Electrosystems Pvt Ltd, B-14, 2nd Floor, Ghanshyam Indl Estate, Veera Desai Road, Andheri (West), Mumbai - 400 053, IndiaTel : + 91 22 42537777 Fax : + 91 22 42537700 Email : sales@radix.co.in www.radix.co.inwww.radix.co.in<strong>CAT#258R3</strong>/P2/2/300911/A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!