Getting started with UniOP and CoDeSys integrated controller

Getting started with UniOP and CoDeSys integrated controller

Getting started with UniOP and CoDeSys integrated controller

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Tech-noteAnd this is the macro definition for "PC port for SCM03C" button…The port assignment can be also done directly from the HMI in the System Menu:- enter the comm<strong>and</strong> menu (press for 2 seconds on the touch screen or 2 seconds on theENTER key on non touch screen HMI) <strong>and</strong> select "SYSTEM"- in the System menu scroll the cursor down until you reach the "PRINTER.....OFF-LINE" line- Use left <strong>and</strong> right arrows to change the settings:-- "SCMxx #0 APPLICATION" when you want to download the iPLC project <strong>with</strong><strong>CoDeSys</strong>-- "OFF-LINE" when you want to download the <strong>UniOP</strong> project <strong>with</strong> Designer- Select then "EXIT" to go out of this system menu.10) Now, you are ready to download your projects (<strong>UniOP</strong> <strong>and</strong> <strong>CoDeSys</strong>) to your HMI- Use st<strong>and</strong>ard procedure to download your <strong>UniOP</strong> project to the HMI <strong>with</strong> designer.- When the panel is in operation Mode, use the "PC port for SCM03C" button to reserve thePC port for <strong>CoDeSys</strong>.- In <strong>CoDeSys</strong> software, select then "Online / Login" menu to connect <strong>with</strong> the SCM module- <strong>CoDeSys</strong> will now display a message according to the status of the SCM module; if themodule has already an application loaded on it the following message is displayed:- at the end of the download the PLC_PRG POU will be automatically displayed in monitormode on the <strong>CoDeSys</strong> programming software.11) By default the <strong>CoDeSys</strong> application is downloaded in the module RAM memory; to keep it atpower cycle you need to store the project in the internal SCM flash memory; create then the“Boot Project": the PLC application is stored in the flash memory <strong>and</strong> it will be automatically<strong>started</strong> at each power cycle. The boot project can be created form "Online / Create bootsn021-1 (<strong>Getting</strong> Started <strong>with</strong> <strong>UniOP</strong> <strong>and</strong> <strong>CoDeSys</strong> iPLC).doc - 20.03.2009<strong>Getting</strong> <strong>started</strong> <strong>with</strong> <strong>UniOP</strong> <strong>and</strong> <strong>CoDeSys</strong> <strong>integrated</strong> <strong>controller</strong> 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!